WIREMOLD
Frequently asked questions
Common questions about WIREMOLD from 3G Electric.
What are the available outlet configurations for Wiremold service poles?
Wiremold service poles are available with either four or six NEMA 5-20R outlets. Models with outlets typically include two 20A 125V duplex receptacles, providing four outlets total. For example, the 25DTP4 has four outlets, while the 30TP-4V has six. Blank poles without outlets are also available for field customization. All outlet configurations are designed for 125V applications and use standard NEMA 5-20R receptacles, which accept 20A plugs. The number of outlets and their arrangement should be selected based on the power requirements of the equipment to be connected.
What is the difference between a two-channel and a single-channel Wiremold service pole?
A two-channel Wiremold service pole has separate compartments for power and low-voltage cabling, which helps maintain separation between high-voltage and data lines. Single-channel poles have one compartment and are typically used for power only or where low-voltage separation is not required. For instance, the 25DTP4 is a two-channel pole, while the 30TC-2V is a single-channel blank pole. The choice depends on whether data or communication cables need to be routed alongside power. Two-channel models often include a communications insert mounting adapter to facilitate low-voltage wiring.
What are the standard lengths and cross-sectional dimensions of Wiremold service poles?
Wiremold service poles are commonly available in lengths of 10 ft 5 in or 12 ft 5 in. Cross-sectional dimensions vary by model: for example, the 25DTP4 measures 2 1/4 in by 2 1/4 in, the 30TP-2V measures 2 3/4 in by 1 1/2 in, and the 30TC-412V measures 2 3/4 in by 3 in. These dimensions affect the pole's capacity for wiring and its visual profile in the workspace. When selecting a pole, consider the available ceiling height and the amount of cabling to be routed. Longer lengths are available for higher ceilings, and larger cross-sections accommodate more cables or additional outlets.
Can Wiremold service poles be used for data and communication cabling?
Yes, many Wiremold service poles are designed to route both power and low-voltage cabling. Two-channel models provide separate pathways to maintain isolation between power and data lines. Some models, such as the 25DTP4ACT, include a Communications Insert Mounting Adapter for installing communication inserts. Blank poles can be field-modified with knockouts and adapters to accommodate data outlets. When routing data cables, ensure that the pole's channel capacity and bend radius are suitable for the cable type. Always follow applicable codes and standards for separation of power and communication circuits.
What is the purpose of knockouts in Wiremold blank service poles?
Knockouts in Wiremold blank service poles are pre-formed openings that can be removed to install outlets, connectors, or other devices. For example, the 30TC-2V has one knockout, and the 30TC-412V has two knockouts. These allow field customization of the pole to meet specific power or data requirements. Knockouts are typically sized to accept standard electrical boxes or fittings. When using knockouts, ensure that the installed devices are compatible with the pole's dimensions and that all openings are properly closed to maintain the pole's integrity. Blank poles with knockouts offer flexibility for contractors and facility managers.
Does 3G Electric supply WIREMOLD products?
Yes — 3G Electric (S) Pte. Ltd. supplies WIREMOLD products. We stock the WIREMOLD catalog and supply genuine factory-original products with full manufacturer warranty and technical support.