MILLIMAR
Frequently asked questions
Common questions about MILLIMAR from 3G Electric.
What is the difference between the MILLIMAR P2004F and P2010UB pencil probes?
The P2004F and P2010UB are both plunger-type inductive pencil probes with 2.5 m cables, but they differ in accuracy class. The P2004F is specified at 3 µm accuracy with a repeatability of 0.1, while the P2010UB is specified at 20 µm accuracy. The choice between them depends on the tolerance of the feature being measured: the 3 µm probe is suited to tighter-tolerance dimensional inspection, while the 20 µm probe may be adequate for less demanding checks or where a larger measuring range is needed. Both are part of the Mahr Millimar series and use the same cable length, so the selection is primarily driven by accuracy requirement and compatibility with the signal-conditioning unit.
What is the measuring range and accuracy of the MILLIMAR 2000 W digital indicator?
The MILLIMAR 2000 W digital comparator has a measuring range of 0.001 mm to 1 mm (0.0000390625 in to 0.04 in) and an accuracy of ±0.0007 mm over that 1 mm range. It features inch/metric display switching and an IP64 protection rating. The non-removable flat back allows it to be mounted in fixtures or stands. This indicator is part of a family that includes the 2000 Wi, 2001 W, and 2001 Wi, which share the same range and accuracy but differ in configuration details such as display units or mounting. For replacement or new installations, verify the model suffix against the existing setup to ensure compatibility.
Are MILLIMAR pencil probes compatible with any Mahr amplifier or do they require a specific model?
MILLIMAR inductive probes are designed to work with Mahr signal-conditioning electronics, typically the Millimar series amplifiers and comparators. Compatibility depends on the probe connector type and the input specifications of the amplifier. The probes listed by 3G Electric, such as the P2004F, P2004MA, P2004TA, and P2010UB, use a standard Mahr inductive probe interface. When selecting a replacement probe, confirm the connector and electrical characteristics match the existing amplifier. Datasheets for each SKU provide the necessary details. If you are building a new system, the digital indicators like the 2000 W can be paired with these probes to form a complete measurement chain.
What does the IP64 rating on MILLIMAR digital indicators mean for shop-floor use?
IP64 indicates that the enclosure is protected against dust ingress and water splashes from any direction. For shop-floor use, this means the indicator can be used in environments where coolant mist, metal chips, or occasional splashes are present, provided it is not submerged. It is not intended for washdown areas or continuous exposure to liquids. The non-removable flat back and the sealed construction help maintain measurement stability in typical machining and inspection areas. When installing, ensure the cable entry and mounting surfaces are not damaged, as the IP rating depends on the integrity of the seals and housing.
Can MILLIMAR pencil probes be used for runout measurement on rotating parts?
Yes, plunger-type pencil probes such as the P2004F and P2004MA are commonly used for runout and concentricity checks on rotating parts. The probe tip contacts the surface, and the inductive sensor converts displacement into an electrical signal that the amplifier or digital indicator displays. For runout measurement, the workpiece is rotated and the total indicated reading (TIR) is observed. The 3 µm accuracy class of these probes is suitable for detecting small deviations. The 2.5 m cable allows the probe to be positioned at the measurement point while the electronics remain in a safe location. Ensure the probe is mounted rigidly and the tip is perpendicular to the surface for accurate results.
What support does 3G Electric provide for MILLIMAR products?
3G Electric supplies MILLIMAR pencil probes and digital indicators with SKU-level documentation, including manufacturer part numbers, accuracy specifications, cable lengths, and protection ratings. The catalog currently lists 42 SKUs. For technical buyers, this means you can cross-reference existing Mahr part numbers, verify compatibility with your signal-conditioning equipment, and confirm that the accuracy and range meet your measurement requirements. 3G Electric coordinates logistics for global delivery and can provide datasheets for each listed product. The company does not manufacture MILLIMAR products; it distributes them as part of a broader industrial-equipment offering that includes burners, pumps, and gas controls, allowing consolidated procurement from a single source.