EXW Singapore — collect or forward from our Singapore office.

3G Electric

LABEXACT

LABEXACT is a brand of filtration media and laboratory consumables used in analytical, environmental, and industrial laboratory workflows. The product line includes glass fiber filters, membrane filters, syringe filters, and related sample-preparation items. LABEXACT filters are specified by pore size, diameter, thickness, and material so that technical buyers can match a filter to a retention requirement, a filtration format, or an instrument protocol. The E grade glass fiber filters in the line, for example, are available in diameters from 2.4 cm to 15 cm with a 0.35 mm thickness and a 1.5 µm pore size, which places them in the fine-particle-retention range used for gravimetric analysis, air monitoring, and general sample preparation. The polyethersulfone (PES) membrane filter in the line is a 47 mm diameter, 0.45 µm pore size, non-sterile disc intended for aqueous and solvent-based laboratory filtration. These are consumable items, so the practical buying criteria are dimensional compatibility, material compatibility with the sample and solvent, pore size, and lot-to-lot consistency rather than installed-equipment features. LABEXACT products are typically selected alongside filtration glassware, vacuum manifolds, syringes, and analytical balances, and they are consumed in routine QC, method development, and environmental sampling. 3G Electric supplies the LABEXACT line as part of its broader industrial and laboratory equipment catalog. For a distributor, the relevant support is commercial and logistical: confirming the correct part number and format, checking that the requested diameter, pore size, and material match the application, and coordinating availability across the catalog. Because LABEXACT part numbers are specific to diameter and grade, buyers should order against the manufacturer part number where possible. 3G Electric can quote LABEXACT filtration media and lab consumables for delivery to laboratory, plant, and field locations, and can combine those items with other equipment on the same order. The catalog includes both the E grade glass fiber filter family across multiple diameters and the PES membrane filter format, which covers two common filtration media types: a binder-free glass microfiber for high particle retention and a hydrophilic membrane for aqueous and solvent filtration. Buyers working to a written method should verify the pore size, diameter, and material against the method before ordering, since those three parameters determine retention and flow behavior. Where a method specifies a grade or a diameter, the LABEXACT part number is the reliable identifier. 3G Electric's role is to keep the correct LABEXACT part numbers available and to ship them to the buyer's required location.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
Worldwide
Origin
EXW Singapore
Collect or forward from our office
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Browse:
Show
Page 7 of 20

About LABEXACT

LABEXACT is a brand of filtration media and laboratory consumables used in analytical, environmental, and industrial laboratory workflows. The product line includes glass fiber filters, membrane filters, syringe filters, and related sample-preparation items. LABEXACT filters are specified by pore size, diameter, thickness, and material so that technical buyers can match a filter to a retention requirement, a filtration format, or an instrument protocol. The E grade glass fiber filters in the line, for example, are available in diameters from 2.4 cm to 15 cm with a 0.35 mm thickness and a 1.5 µm pore size, which places them in the fine-particle-retention range used for gravimetric analysis, air monitoring, and general sample preparation. The polyethersulfone (PES) membrane filter in the line is a 47 mm diameter, 0.45 µm pore size, non-sterile disc intended for aqueous and solvent-based laboratory filtration. These are consumable items, so the practical buying criteria are dimensional compatibility, material compatibility with the sample and solvent, pore size, and lot-to-lot consistency rather than installed-equipment features. LABEXACT products are typically selected alongside filtration glassware, vacuum manifolds, syringes, and analytical balances, and they are consumed in routine QC, method development, and environmental sampling. 3G Electric supplies the LABEXACT line as part of its broader industrial and laboratory equipment catalog. For a distributor, the relevant support is commercial and logistical: confirming the correct part number and format, checking that the requested diameter, pore size, and material match the application, and coordinating availability across the catalog. Because LABEXACT part numbers are specific to diameter and grade, buyers should order against the manufacturer part number where possible. 3G Electric can quote LABEXACT filtration media and lab consumables for delivery to laboratory, plant, and field locations, and can combine those items with other equipment on the same order. The catalog includes both the E grade glass fiber filter family across multiple diameters and the PES membrane filter format, which covers two common filtration media types: a binder-free glass microfiber for high particle retention and a hydrophilic membrane for aqueous and solvent filtration. Buyers working to a written method should verify the pore size, diameter, and material against the method before ordering, since those three parameters determine retention and flow behavior. Where a method specifies a grade or a diameter, the LABEXACT part number is the reliable identifier. 3G Electric's role is to keep the correct LABEXACT part numbers available and to ship them to the buyer's required location.

Common Applications

  • Environmental and industrial hygiene — LABEXACT E grade glass fiber filters (1.5 µm, 0.35 mm) for air monitoring and particulate sampling.
  • Analytical laboratories — LABEXACT E grade glass fiber filters in 2.4 cm to 15 cm diameters for gravimetric analysis and sample preparation.
  • Pharmaceutical and QC labs — LABEXACT 47 mm PES membrane filters (0.45 µm) for aqueous and solvent-based sample filtration.
  • Food and beverage testing — LABEXACT PES membrane filters for particulate removal ahead of instrumental analysis.
  • Research and method development — LABEXACT E grade glass fiber filters across multiple diameters for retention and flow studies.
  • Field sampling programs — LABEXACT glass fiber filters supplied in assorted diameters for air and particulate monitoring kits.

Frequently asked questions

Common questions about LABEXACT from 3G Electric.

What pore size and thickness are LABEXACT E grade glass fiber filters available in?

The LABEXACT E grade glass fiber filters in the 3G Electric catalog are listed with a 1.5 µm pore size and a 0.35 mm thickness. Diameters in the line include 2.4 cm, 3.7 cm, 4.25 cm, 5.5 cm, 7 cm, 11 cm, and 15 cm, each with its own manufacturer part number. Because the part number changes with diameter, buyers should order against the specific MPN for the disc size their filtration apparatus or method requires. The 1.5 µm retention range is suited to fine-particle capture in gravimetric analysis, air monitoring, and sample preparation.

What is the LABEXACT PES membrane filter used for?

The LABEXACT polyethersulfone (PES) membrane filter is a 47 mm diameter disc with a 0.45 µm pore size, supplied non-sterile. It is used in laboratory filtration of aqueous and solvent-based samples. PES is chosen where a low-binding, hydrophilic membrane is needed and where the sample chemistry is compatible with polyethersulfone. The 0.45 µm pore size is a common retention point for particulate removal ahead of analysis. Buyers should confirm solvent compatibility with PES before use, and confirm that 47 mm is the correct diameter for their filter holder or manifold.

How do I choose between LABEXACT glass fiber filters and PES membrane filters?

The two media serve different retention and flow requirements. LABEXACT E grade glass fiber filters are depth filters with a 1.5 µm pore size and 0.35 mm thickness, used where high particle loading and fine retention are needed, such as gravimetric analysis and air monitoring. The LABEXACT PES membrane filter is a 0.45 µm surface membrane at 47 mm diameter, used for aqueous and solvent filtration where a defined pore size and low extractables matter. Selection depends on the method's specified pore size, the sample matrix, and the filtration format. Where a written method names a grade or membrane type, follow that specification.

What diameters are available in the LABEXACT E grade glass fiber filter line?

The LABEXACT E grade glass fiber filters listed by 3G Electric cover diameters of 2.4 cm, 3.7 cm, 4.25 cm, 5.5 cm, 7 cm, 11 cm, and 15 cm. All share the same 0.35 mm thickness and 1.5 µm pore size; only the disc diameter and the corresponding manufacturer part number differ. This range covers small syringe-type and holder formats through larger discs used in air monitoring and gravimetric work. Buyers should match the disc diameter to the filtration apparatus and order by the MPN for that diameter.

Can 3G Electric supply LABEXACT filtration media outside Singapore?

Yes. 3G Electric distributes industrial and laboratory equipment with global shipping, so LABEXACT filtration media and lab consumables can be quoted and delivered to laboratory, plant, and field locations outside Singapore. Orders can combine LABEXACT filters with other catalog items. Because LABEXACT part numbers are diameter- and grade-specific, provide the manufacturer part number or the exact diameter, pore size, and material when requesting a quote so the correct item is supplied.

What should I check before ordering a LABEXACT filter?

Confirm four parameters against your method or apparatus: material (glass fiber or PES), pore size (1.5 µm for the E grade glass fiber filters, 0.45 µm for the PES membrane filter), diameter (2.4 cm to 15 cm for the E grade line, 47 mm for the PES disc), and sterility where relevant, since the PES membrane filter is supplied non-sterile. Also confirm chemical compatibility between the sample or solvent and the filter material. Ordering against the LABEXACT manufacturer part number avoids ambiguity where multiple diameters share the same grade and pore size.