What is the difference between the APC by Schneider Electric metered and non-metered PDUs?
Metered PDUs include a local display or network interface that reports current draw per phase or per outlet, allowing capacity planning and load balancing. Non-metered PDUs, such as the AP9564 and AP7530 listed by 3G Electric, distribute power without local metering. Both types are available in horizontal or vertical rack-mount configurations with various input plugs and outlet types. The choice depends on whether you need to monitor power consumption at the rack level or simply distribute power to connected equipment.
What input and outlet configurations are available for APC by Schneider Electric standard PDUs?
APC standard PDUs in the 3G Electric catalog include models with 120V AC or 230V AC input. Examples include the AP7541 with a NEMA L6-30P plug and 24 outlets (20 C13 and 4 C19), the AP9564 with a NEMA L5-20P plug and 10 NEMA 5-20R outlets, and the AP7530 with a NEMA L5-20P plug and 24 NEMA 5-20R outlets. Mounting can be horizontal or vertical, with front-facing outlets. Buyers should match the PDU input plug to the available branch circuit receptacle and confirm outlet types match equipment power cords.
What are the specifications of the APC by Schneider Electric ACF001 rack cooling fan?
The ACF001 air distribution fan operates on 120V AC and delivers 503 cfm at 0.000 in static pressure. It is designed for rack mounting to improve airflow and reduce hot spots within equipment racks. The fan is part of the APC rack cooling accessory line and is typically used in enclosed racks where passive convection is insufficient. When selecting a fan, consider the rack's thermal load, available rack units, and power source. The 503 cfm rating is measured at zero static pressure, so actual airflow will be lower when installed in a rack with impedance.
What lengths and connector types are available for APC by Schneider Electric power cords?
APC power cords in the 3G Electric catalog include models such as the AP9873, an 8.25 ft cord with a NEMA 5-20P plug and C19 receptacle, and the AP9879, a 6.5 ft cord with a C20 plug and C13 receptacle. Both use 3/12 gauge conductors with SJT rubber jackets. These cords are used to connect equipment to PDUs or wall outlets where the standard cord is too short or the connector type does not match. Verify the plug and receptacle types against your power source and equipment inlet before ordering.
How do I select an APC by Schneider Electric PDU for a rack with mixed C13 and C19 equipment?
For mixed equipment, choose a PDU that provides both C13 and C19 outlets. The AP7541, for example, has 20 C13 and 4 C19 receptacles with a NEMA L6-30P input plug at 230V AC. This allows connecting servers, switches, and other devices with C14 inlets to C13 outlets, and higher-power equipment with C20 inlets to C19 outlets. Confirm the total connected load does not exceed the PDU's input current rating and that the branch circuit can supply the required voltage and amperage.
What should I check before ordering an APC by Schneider Electric PDU from 3G Electric?
Verify the input voltage and plug type match your power source, the outlet types and counts match your equipment cords, and the mounting orientation (horizontal or vertical) fits your rack. Also confirm the PDU's current rating is adequate for the connected load. The 3G Electric catalog lists specifications such as voltage, outlets, plug type, receptacle type, and mounting for each SKU. If you need a specific manufacturer part number, include it in your quote request to ensure an exact match.