Goods are offered EXW Singapore — collection from our Singapore facility.

Home›Resources›76F-105-01 Shut off Valve 1.5" (76F-105-01): International Buyer's Guide to Gas Shut-Off Valves and Actuators

76F-105-01 Shut off Valve 1.5" (76F-105-01): International Buyer's Guide to Gas Shut-Off Valves and Actuators

A practical International buyer's guide to the 76F-105-01 Shut off Valve 1.5" (76F-105-01), covering sizing, actuator compatibility, voltage/frequency variants, and how to source the right gas shut-off valve and actuator combination through 3G Electric.
Publication Date24 November 2026 · 08:45 am
Technical Reviewer3G Electric Technical Team
76F-105-01 Shut off Valve 1.5" (76F-105-01): International Buyer's Guide to Gas Shut-Off Valves and Actuators
Gas-valves
Table of Contentsexpand_more

The 76F-105-01 Shut off Valve 1.5" (76F-105-01) is a 1.5-inch (DN40) gas shut-off valve body for industrial gas trains, and it is normally supplied together with a compatible electric actuator. Buyers in International markets should confirm body size, actuator control signal, and local 50 Hz or 60 Hz supply before ordering.

What is a 76F-105-01 Shut off Valve 1.5" (76F-105-01)?

A 76F-105-01 Shut off Valve 1.5" (76F-105-01) is a 1.5-inch (DN40) shut-off valve body used to isolate or open gas flow in industrial combustion and heating systems. It is typically actuated by a REDHAT electric actuator compatible with ASCO Series 158 or V710 valve bodies, giving on/off or High/Low/Off control.

In practice, the valve body and actuator are specified as a pair: the body sets the pipe size and flow capacity, while the actuator sets the control signal, opening time, and safety features such as proof of closure.

Quotable definition

A 76F-105-01 Shut off Valve 1.5" (76F-105-01) is a 1.5-inch (DN40) industrial gas shut-off valve body designed to be fitted with an electric actuator for on/off or High/Low/Off control of gas flow in combustion, heating, and process gas trains.

How does a gas shut-off valve work?

The valve body sits in the gas line and opens or closes the flow path when the actuator drives its stem. The actuator receives a control signal — typically 120 V AC on/off or High/Low/Off — and moves the valve to the commanded position.

Safety-critical installations often require a proof-of-closure switch so the control system can confirm the valve has fully closed before allowing ignition. REDHAT actuators compatible with ASCO Series V710 bodies include this feature.

Spec table: typical 1.5" gas shut-off valve and actuator attributes

AttributeTypical value / optionNotes
Valve body size1.5 in (DN40)Confirm line size and flange/thread standard
Actuator supply voltage120 V ACCheck local 50 Hz / 60 Hz supply
Control signalOn/Off or High/Low/OffMatch to burner control sequence
Enclosure ratingNEMA 1Indoor general-purpose use
Proof of closureAvailable on selected modelsRequired for many safety interlock schemes
Opening timeFast opening (model-dependent)Confirm against burner light-off requirements

Which actuator type suits your application?

Three common actuator configurations appear in the 3G Electric catalogue, all REDHAT units compatible with ASCO gas shut-off valve bodies:

  • On/Off actuator — simplest control, 120 V AC signal, damper shaft with arm, NEMA 1. Suits basic isolation duty.
  • High/Low/Off actuator with fast opening — for industrial heating systems that need staged gas flow regulation.
  • High/Low/Off actuator with proof of closure — for safety-critical gas trains requiring valve-position feedback.

Selection criteria: how to choose a 1.5" gas shut-off valve and actuator

  1. Confirm line size and connection standard. The 76F-105-01 is a 1.5-inch (DN40) body; verify flange or thread standard against your pipework.
  2. Match the actuator control signal. Choose on/off for simple isolation, or High/Low/Off where staged gas flow is required.
  3. Check supply voltage and frequency. REDHAT actuators in this range are 120 V AC; confirm whether your site runs 50 Hz or 60 Hz and whether a transformer or regional variant is needed.
  4. Decide on proof of closure. Required where the burner management system must verify full closure before ignition.
  5. Confirm enclosure rating against environment. NEMA 1 suits indoor general-purpose locations; outdoor or washdown areas need a different rating.
  6. Verify opening time against the burner sequence. Fast-opening actuators suit specific light-off profiles — check against the OEM burner manual.

Product selection ladder: REDHAT actuators for gas shut-off valve bodies

ModelCompatible valve bodySupplyControl signalKey featureEnclosure
REDHAT On/Off Actuator for ASCO Series 158 Gas Shut-Off Valve BodiesASCO Series 158120 V ACOn/OffDamper shaft with armNEMA 1
REDHAT High/Low/Off Actuator for ASCO Series 158 Gas Shut-Off Valve BodiesASCO Series 158120 V ACHigh/Low/OffFast opening timeNEMA 1
REDHAT High/Low/Off Actuator with Proof of Closure for ASCO Series V710 Gas Shut-Off Valve BodiesASCO Series V710120 V ACHigh/Low/OffProof of closure switchNEMA 1

Step up the ladder when your burner sequence demands staged gas flow (High/Low/Off) or when safety interlocks require proof of closure. Stay with the on/off unit for simple isolation duty where a single open/close command is sufficient.

Types and applications in International markets

Gas shut-off valves and actuators of this class appear in industrial boilers, furnaces, ovens, and process heating lines. In International markets, buyers often need to reconcile 120 V AC actuators with local 50 Hz or 60 Hz supplies, and to confirm that NEMA 1 enclosures suit the indoor plant environment.

For water-side isolation in irrigation and drip systems, the catalogue also includes the HYDRORAIN Drip Zone Valve Filter Regulator and the RAIN BIRD BVAL501-S 1/2-inch Plastic On/Off Valve — useful where a project spans both gas and water services.

Why source from 3G Electric?

3G Electric interprets the requirement and supplies the right industrial equipment, parts, and supplies across 14 industrial departments — and we supply far more than is listed. Our specialist depth in combustion, pumps, and controls is a trust anchor, not the limit of what we sell.

With 35+ years of experience, we quote parts beyond the catalogue on request. Goods are offered EXW Singapore (collection from our Singapore office); items are shipped to us from our overseas warehouse when not held locally. We do not offer installation, on-site, or remote technical help.

FAQ

What is the 76F-105-01 Shut off Valve 1.5" used for?

It is a 1.5-inch (DN40) gas shut-off valve body for industrial gas trains, paired with an electric actuator to open or isolate gas flow in boilers, furnaces, and process heating equipment. Confirm actuator compatibility and control signal before ordering.

Which actuator is compatible with a 1.5" gas shut-off valve body?

REDHAT actuators compatible with ASCO Series 158 and V710 bodies are the typical match in the 3G Electric catalogue. Choose on/off for simple isolation, or High/Low/Off with proof of closure where safety interlocks require valve-position feedback.

Can I use a 120 V AC actuator on a 50 Hz supply in International markets?

Confirm the actuator's rated frequency against your local supply before ordering. Many International sites run 50 Hz while others run 60 Hz; where the actuator is rated for 60 Hz only, a suitable transformer or regional variant may be required. Always verify against the OEM datasheet.

Where can I buy a 76F-105-01 Shut off Valve 1.5" in International markets?

3G Electric supplies gas shut-off valve bodies and compatible REDHAT actuators to International buyers, offered EXW Singapore. Contact us with your line size, actuator control signal, and supply voltage for a quote.

What is the difference between on/off and High/Low/Off gas shut-off actuators?

On/off actuators provide a single open or closed command, suiting simple isolation. High/Low/Off actuators support staged gas flow for modulated heating, and some include a proof-of-closure switch for safety-critical sequences.

Key takeaways

  • The 76F-105-01 Shut off Valve 1.5" (76F-105-01) is a 1.5-inch (DN40) gas shut-off valve body for industrial gas trains.
  • Pair it with a REDHAT actuator compatible with ASCO Series 158 or V710 bodies, matched to your control signal.
  • Confirm 50 Hz / 60 Hz supply and NEMA 1 suitability for your International site before ordering.
  • Proof of closure is required where burner safety interlocks demand valve-position feedback.
  • 3G Electric supplies across 14 industrial departments, with quotes for parts beyond the catalogue, EXW Singapore.

Contact 3G Electric for a quote on the 76F-105-01 Shut off Valve 1.5" (76F-105-01) or a compatible REDHAT actuator. We interpret your requirement and supply the right part — installation and on-site or remote technical help are not offered.

Frequently Asked Questions
What is the 76F-105-01 Shut off Valve 1.5" used for?+
It is a 1.5-inch (DN40) gas shut-off valve body for industrial gas trains, paired with an electric actuator to open or isolate gas flow in boilers, furnaces, and process heating equipment. Confirm actuator compatibility and control signal before ordering.
Which actuator is compatible with a 1.5" gas shut-off valve body?+
REDHAT actuators compatible with ASCO Series 158 and V710 bodies are the typical match in the 3G Electric catalogue. Choose on/off for simple isolation, or High/Low/Off with proof of closure where safety interlocks require valve-position feedback.
Can I use a 120 V AC actuator on a 50 Hz supply in International markets?+
Confirm the actuator's rated frequency against your local supply before ordering. Many International sites run 50 Hz while others run 60 Hz; where the actuator is rated for 60 Hz only, a suitable transformer or regional variant may be required. Always verify against the OEM datasheet.
Where can I buy a 76F-105-01 Shut off Valve 1.5" in International markets?+
3G Electric supplies gas shut-off valve bodies and compatible REDHAT actuators to International buyers, offered EXW Singapore. Contact us with your line size, actuator control signal, and supply voltage for a quote.
What is the difference between on/off and High/Low/Off gas shut-off actuators?+
On/off actuators provide a single open or closed command, suiting simple isolation. High/Low/Off actuators support staged gas flow for modulated heating, and some include a proof-of-closure switch for safety-critical sequences.