We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 1/2 in Dial - Front-Flange Panel-Mount with Brass/Bronze Wetted Parts
WINTERSFront-Flange Panel-Mount with Brass/Bronze Wetted Parts

WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 1/2 in Dial

The WINTERS Panel-Mount Pressure Gauge is a front-flange panel-mount gauge with brass/bronze wetted parts, featuring a 2 1/2 in dial and 1/4 in NPT male connection. It offers an accuracy of ±1.5% and is…

SKU 3G-OTH-175026

Also listed as: PFQ902DRY25FF · PFQ902 DRY 25FF

Brand
WINTERS
Item
Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 1/2 in Dial
Category
Front-Flange Panel-Mount with Brass/Bronze Wetted Parts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

WINTERS
Manufacturer Part Number
PFQ902-DRY-25FF
Type
0 psi to 30 psi, 4
Dial
2 1/2 in
Accuracy
±1.5%
NPT Male
1/4 in
Gauge Wetted Parts
Brass / Bronze
Vibration Resistance Properties
Field-Fillable

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WINTERS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WINTERS Panel-Mount Pressure Gauge is a front-flange panel-mount gauge with brass/bronze wetted parts, featuring a 2 1/2 in dial and 1/4 in NPT male connection. It offers an accuracy of ±1.5% and is field-fillable for vibration resistance, covering a range of 0 psi to 30 psi (MPN PFQ902-DRY-25FF).

Frequently Asked Questions

What is the WINTERS Panel-Mount Pressure Gauge used for?

The WINTERS Panel-Mount Pressure Gauge is used for measuring pressure in industrial panels, hydraulic systems, and pneumatic equipment. Its front-flange design allows flush mounting in control panels, while the brass/bronze wetted parts make it suitable for non-corrosive gases and liquids. The field-fillable feature dampens vibration in pump and compressor applications.

What are the specifications of the WINTERS PFQ902-DRY-25FF pressure gauge?

The WINTERS PFQ902-DRY-25FF has a 2 1/2 in dial, 1/4 in NPT male connection, and a range of 0 psi to 30 psi. Accuracy is ±1.5%. Wetted parts are brass/bronze, and the gauge is field-fillable for vibration resistance. It is a front-flange panel-mount model with a dry case.

Where to buy the WINTERS panel-mount pressure gauge worldwide?

You can source the WINTERS panel-mount pressure gauge through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time. 3G Electric supplies genuine WINTERS gauges to industrial buyers globally.

How to install a WINTERS front-flange pressure gauge?

To install the WINTERS front-flange gauge, cut a panel hole to the flange diameter, insert the gauge from the front, and secure it with the provided mounting bracket or screws. Apply thread sealant to the 1/4 in NPT male connection and tighten to 20 ft-lb. For vibration-prone systems, fill the case with glycerin before installation.

Used in

Common applications for WINTERS
Process control — WINTERS PPC series process pressure gauges for monitoring hydraulic and pneumatic systems in manufacturing plants.
HVAC systems — WINTERS PFD series differential pressure gauges for measuring filter pressure drop in air handling units.
Panel mounting — WINTERS PFP series back-flange panel-mount gauges for control panels in industrial automation.
Temperature measurement — WINTERS TBR series threaded thermowells for protecting temperature sensors in pipelines.
Water treatment — WINTERS differential pressure gauges for monitoring pressure across filtration membranes.
Oil and gas — WINTERS all-stainless steel pressure gauges for corrosive media in upstream and downstream processes.

WINTERS Products

3G Electric supplies WINTERS front-flange panel-mount with brass/bronze wetted parts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2487-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2487-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 1/2 in Dial, 1/4 in NPT Male, 4 (MPN PFQ903-DRY-25FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 1/2 in Dial, 1/4 in NPT Male, 4 (MPN PFQ903-DRY-25FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 300 psi, 2 1/2 in Dial, 1/4 in NPT Male (MPN PFQ907-DRY-25FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 300 psi, 2 1/2 in Dial, 1/4 in NPT Male (MPN PFQ907-DRY-25FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 15 psi, 2 1/2 in Dial, 1/4 in NPT Male, 4 (MPN PFQ901-DRY-25FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 15 psi, 2 1/2 in Dial, 1/4 in NPT Male, 4 (MPN PFQ901-DRY-25FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2435-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 30 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2435-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 1/2 in Dial, 1/4 in NPT Male (MPN PFQ904-DRY-25FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 1/2 in Dial, 1/4 in NPT Male (MPN PFQ904-DRY-25FF)

More from WINTERS

View all WINTERS parts
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 160 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2438-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 160 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2438-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2489-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2489-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2437-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 100 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2437-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2436-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2436-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 300 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2440-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 300 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2440-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2488-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 60 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2488-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 200 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2491-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 200 psi, 2 in Dial, 1/4 in NPT Male, PFQ (MPN PFQ2491-DRY-2FF)
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 15 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2434-DRY-2FF)
WINTERS
WINTERS Panel-Mount Pressure Gauge: Front Flange, 0 psi to 15 psi, 2 in Dial, 1/8 in NPT Male, PFQ (MPN PFQ2434-DRY-2FF)