We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

WILKERSON Air Line Lockout Valve: 1/2 in NPT, 1/2 in NPT Outlet Size, 246 psi Max Op Pressure - Wilkerson Compressed Air Line Lockout Valves for FRLs
WILKERSONWilkerson Compressed Air Line Lockout Valves for FRLs

WILKERSON Air Line Lockout Valve: 1/2 in NPT, 1/2 in NPT Outlet Size, 246 psi Max Op Pressure

The WILKERSON Air Line Lockout Valve (SKU 3G-OTH-144214) is a 1/2 in NPT compressed air line lockout valve for FRLs, part of the V60 series (MPN V60-04-B000B-17). It features a 1/2 in NPT outlet size and a maximum…

SKU 3G-OTH-144214

Also listed as: V6004B000B17 · V60 04 B000B 17

Brand
WILKERSON
Item
Air Line Lockout Valve: 1/2 in NPT, 1/2 in NPT Outlet Size, 246 psi Max Op Pressure
Category
Wilkerson Compressed Air Line Lockout Valves for FRLs
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

WILKERSON
Manufacturer Part Number
V60-04-B000B-17
Type
V60
Max Op Pressure
246 psi
NPT Outlet Size
1/2 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WILKERSON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WILKERSON Air Line Lockout Valve (SKU 3G-OTH-144214) is a 1/2 in NPT compressed air line lockout valve for FRLs, part of the V60 series (MPN V60-04-B000B-17). It features a 1/2 in NPT outlet size and a maximum operating pressure of 246 psi.

Frequently Asked Questions

What is a Wilkerson V60 air line lockout valve used for?

The Wilkerson V60 lockout valve isolates compressed air in FRL systems for safe maintenance. It is used in industrial pneumatic circuits to lock out energy per OSHA lockout/tagout procedures, ensuring worker safety during equipment servicing.

What are the specifications of the Wilkerson V60-04-B000B-17 lockout valve?

The Wilkerson V60-04-B000B-17 is a 1/2 in NPT compressed air line lockout valve with a 1/2 in NPT outlet size and a maximum operating pressure of 246 psi. It is part of the V60 series and is designed for use with FRL units.

Where to buy a Wilkerson V60 lockout valve worldwide?

3G Electric supplies the Wilkerson V60 lockout valve worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this genuine Wilkerson part.

How to install a Wilkerson V60 lockout valve?

Install the Wilkerson V60 lockout valve in the compressed air line upstream of the FRL unit. Use thread sealant on the 1/2 in NPT ports, tighten to manufacturer torque specs, and test for leaks. Always follow lockout/tagout procedures before servicing downstream equipment.

Used in

Common applications for WILKERSON
Manufacturing assembly lines — WILKERSON D18-03-FKG0B FRL unit for pneumatic tool lubrication and air preparation.
Packaging machinery — WILKERSON B08-02-FKG0B filter/regulator for consistent pressure control in film sealing systems.
Chemical processing plants — WILKERSON M28-04-BK00B coalescing filter for oil-free air supply to instrumentation.
Automotive paint booths — WILKERSON F26-04-FG0 particulate filter for removal of water and dirt from compressed air lines.
Food and beverage production — WILKERSON F16-04-000 filter for pre-filtration before HEPA or sterile air systems.
Pharmaceutical cleanrooms — WILKERSON M18-04-BK00B coalescing filter for 0.5 micron oil aerosol removal in critical air supplies.

WILKERSON Products

3G Electric supplies WILKERSON wilkerson compressed air line lockout valves for frls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WILKERSON Compressed Air Lubricator: Mist, 3/4 in NPT, 196 cfm, 150 psi Max Op Pressure, Screwdriver (MPN L30-06-000)
WILKERSON
WILKERSON Compressed Air Lubricator: Mist, 3/4 in NPT, 196 cfm, 150 psi Max Op Pressure, Screwdriver (MPN L30-06-000)
WILKERSON Compressed Air Lubricator: Mist, 1 in NPT, 374 cfm, 150 psi Max Op Pressure, Screwdriver (MPN L30-08-000)
WILKERSON
WILKERSON Compressed Air Lubricator: Mist, 1 in NPT, 374 cfm, 150 psi Max Op Pressure, Screwdriver (MPN L30-08-000)
WILKERSON Compressed Air Lubricator: Mist, 1 in NPT, 374 cfm, 200 psi Max Op Pressure, Screwdriver (MPN L30-08-G00)
WILKERSON
WILKERSON Compressed Air Lubricator: Mist, 1 in NPT, 374 cfm, 200 psi Max Op Pressure, Screwdriver (MPN L30-08-G00)
WILKERSON Filter/Regulator/Lubricator: 1/2 in NPT, 90 cfm, 150 psi Max Op Pressure, 5 micron (MPN D18-04-FKG0B)
WILKERSON
WILKERSON Filter/Regulator/Lubricator: 1/2 in NPT, 90 cfm, 150 psi Max Op Pressure, 5 micron (MPN D18-04-FKG0B)
WILKERSON Filter/Regulator/Lubricator: 1/4 in NPT, 45 cfm, 150 psi Max Op Pressure, 5 micron (MPN D18-02-FKG0B)
WILKERSON
WILKERSON Filter/Regulator/Lubricator: 1/4 in NPT, 45 cfm, 150 psi Max Op Pressure, 5 micron (MPN D18-02-FKG0B)
WILKERSON Compressed Air Lubricator: Mist, 3/4 in NPT, 196 cfm, 200 psi Max Op Pressure, Screwdriver (MPN L30-06-G00)
WILKERSON
WILKERSON Compressed Air Lubricator: Mist, 3/4 in NPT, 196 cfm, 200 psi Max Op Pressure, Screwdriver (MPN L30-06-G00)

More from WILKERSON

View all WILKERSON parts
WILKERSON Air Line Lockout Valve: 3/4 in NPT, 3/4 in NPT Outlet Size, 246 psi Max Op Pressure, V73 (MPN V73-06-B000B)
WILKERSON
WILKERSON Air Line Lockout Valve: 3/4 in NPT, 3/4 in NPT Outlet Size, 246 psi Max Op Pressure, V73 (MPN V73-06-B000B)
WILKERSON Air Line Lockout Valve: 1/2 in NPT, 1/2 in NPT Outlet Size, 246 psi Max Op Pressure, V73 (MPN V73-04-B000B)
WILKERSON
WILKERSON Air Line Lockout Valve: 1/2 in NPT, 1/2 in NPT Outlet Size, 246 psi Max Op Pressure, V73 (MPN V73-04-B000B)
WILKERSON Air Line Lockout Valve: 3/8 in NPT, 3/8 in NPT Outlet Size, 246 psi Max Op Pressure, V60 (MPN V60-03-B000B)
WILKERSON
WILKERSON Air Line Lockout Valve: 3/8 in NPT, 3/8 in NPT Outlet Size, 246 psi Max Op Pressure, V60 (MPN V60-03-B000B)
WILKERSON Air Line Lockout Valve: 1/4 in NPT, 1/4 in NPT Outlet Size, 246 psi Max Op Pressure, V40 (MPN V40-02-B000B)
WILKERSON
WILKERSON Air Line Lockout Valve: 1/4 in NPT, 1/4 in NPT Outlet Size, 246 psi Max Op Pressure, V40 (MPN V40-02-B000B)