The WILKERSON Filter/Regulator/Lubricator (FRL) model D28-06-FLG0B is a 3/4 in NPT unit with a maximum operating pressure of 250 psi and a flow capacity of 150 cfm. It features a 5 micron filtration level and is part…

SKU 3G-OTH-140626

Also listed as: D2806FLG0B · D28 06 FLG0B

Brand
WILKERSON
Item
D28-06-FLG0B Filter/Regulator/Lubricator
Part Number
D28-06-FLG0B
Category
Wilkerson Filter, Regulator & Lubricators (FRLs)
Available to Order
Also known as:D28-06-FLG0BWILKERSON
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

WILKERSON
Manufacturer Part Number
D28-06-FLG0B
Type
150 cfm, 5 micron
Max Op Pressure
250 psi

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WILKERSON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WILKERSON Filter/Regulator/Lubricator (FRL) model D28-06-FLG0B is a 3/4 in NPT unit with a maximum operating pressure of 250 psi and a flow capacity of 150 cfm. It features a 5 micron filtration level and is part of the D28 series from WILKERSON.

Frequently Asked Questions

What is the WILKERSON D28-06-FLG0B FRL used for?

The WILKERSON D28-06-FLG0B Filter/Regulator/Lubricator (FRL) conditions compressed air in industrial pneumatic systems. It filters particulates down to 5 micron, regulates pressure up to 250 psi, and lubricates downstream tools and actuators. Common applications include manufacturing, assembly lines, and automated machinery requiring clean, regulated, lubricated air.

What are the specifications of the WILKERSON D28-06-FLG0B?

The WILKERSON D28-06-FLG0B is a 3/4 in NPT FRL with a maximum operating pressure of 250 psi and a flow capacity of 150 cfm. It provides 5 micron filtration and is part of the D28 series. The manufacturer part number is D28-06-FLG0B.

Where to buy the WILKERSON D28-06-FLG0B worldwide?

3G Electric supplies the WILKERSON D28-06-FLG0B FRL to customers worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact 3G Electric for pricing and lead time on this WILKERSON model.

How to install a WILKERSON D28 series FRL?

Install the WILKERSON D28 FRL in a vertical position with the bowl down, using pipe sealant on NPT threads. Ensure flow direction matches the arrow on the body. For the D28-06-FLG0B, verify supply pressure does not exceed 250 psi. Drain the filter bowl regularly and replace the 5 micron element per the manufacturer's schedule.

Used in

Common applications for WILKERSON
Manufacturing assembly lines — WILKERSON D18-03-FKG0B FRL unit for pneumatic tool lubrication and air preparation.
Packaging machinery — WILKERSON B08-02-FKG0B filter/regulator for consistent pressure control in film sealing systems.
Chemical processing plants — WILKERSON M28-04-BK00B coalescing filter for oil-free air supply to instrumentation.
Automotive paint booths — WILKERSON F26-04-FG0 particulate filter for removal of water and dirt from compressed air lines.
Food and beverage production — WILKERSON F16-04-000 filter for pre-filtration before HEPA or sterile air systems.
Pharmaceutical cleanrooms — WILKERSON M18-04-BK00B coalescing filter for 0.5 micron oil aerosol removal in critical air supplies.
Not sure this is the right part? Photo-identify it

WILKERSON Products

3G Electric supplies WILKERSON wilkerson filter, regulator & lubricators (frls). We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from WILKERSON

View all WILKERSON parts
Combined filter, regulator, and lubricator unit for compressed air systems. 3/8 in NPT ports, 68 cfm flow capacity, 150 psi maximum operating pressure, and 5 micron filtration. Used to remove particulates, regulate pressure, and add lubricant to protect pneumatic tools and equipment
WILKERSON
Combined filter, regulator, and lubricator unit for compressed air systems. 3/8 in NPT ports, 68 cfm flow capacity, 150 psi maximum operating pressure, and 5 micron filtration. Used to remove particulates, regulate pressure, and add lubricant to protect pneumatic tools and equipment
This combined filter, regulator, and lubricator unit conditions compressed air in pneumatic systems. It filters particulates to 5 micron, regulates pressure up to 250 psi, and provides lubrication. With a flow capacity of 90 cfm and 1/2 in NPT ports, it is suited for industrial air preparation
WILKERSON
This combined filter, regulator, and lubricator unit conditions compressed air in pneumatic systems. It filters particulates to 5 micron, regulates pressure up to 250 psi, and provides lubrication. With a flow capacity of 90 cfm and 1/2 in NPT ports, it is suited for industrial air preparation
Combined compressed air preparation unit integrating filtration, pressure regulation, and lubrication. Features 5 micron filtration, 150 scfm flow capacity, and 250 psig maximum operating pressure with 3/4 in NPT ports. Used in industrial pneumatic systems to condition air for downstream tools and equipment
WILKERSON
Combined compressed air preparation unit integrating filtration, pressure regulation, and lubrication. Features 5 micron filtration, 150 scfm flow capacity, and 250 psig maximum operating pressure with 3/4 in NPT ports. Used in industrial pneumatic systems to condition air for downstream tools and equipment
This combined filter, regulator, and lubricator (FRL) unit prepares compressed air in pneumatic systems. It filters particulates to 5 micron, regulates pressure up to 250 psig, and adds lubricant to downstream equipment. With 1/2 in NPT ports and a flow capacity of 110 scfm, it is suited for general-purpose compressed air preparation
WILKERSON
This combined filter, regulator, and lubricator (FRL) unit prepares compressed air in pneumatic systems. It filters particulates to 5 micron, regulates pressure up to 250 psig, and adds lubricant to downstream equipment. With 1/2 in NPT ports and a flow capacity of 110 scfm, it is suited for general-purpose compressed air preparation

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first