We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
Image not available
WHITE-RODGERSSingle Function

WHITE-RODGERS Single Function Immersion Controller

The WHITE-RODGERS Immersion Controller (SKU 11B18 101S1, MPN 11B18 101S1) is a single-function high-limit/low-limit controller with a 100°F minimum and 240°F maximum temperature range. It features an adjustable…

SKU 3G-OTH-69984

Also listed as: 11B18101S1 · 11B18-101S1

Brand
WHITE-RODGERS
Item
Single Function Immersion Controller
Part Number
11B18 101S1
Category
Single Function
Available to Order
Also known as:11B18 101S1WHITE-RODGERS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

WHITE-RODGERS
Manufacturer Part Number
11B18 101S1
Type
100°F Min, Horizontal/Vertical
Max
240°F
Switch
1
Application
High Limit
Mounting Orientation
Horizontal
Differential Temperature
5°F to 45°F Adjustable
Auto/Manual Switch Included
Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WHITE-RODGERS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WHITE-RODGERS Immersion Controller (SKU 11B18 101S1, MPN 11B18 101S1) is a single-function high-limit/low-limit controller with a 100°F minimum and 240°F maximum temperature range. It features an adjustable differential temperature of 5°F to 45°F, includes an auto/manual switch, and is designed for horizontal mounting orientation.

Frequently Asked Questions

What is the WHITE-RODGERS immersion controller used for?

The WHITE-RODGERS immersion controller is used as a high-limit or low-limit safety device in industrial heating processes. It monitors fluid temperature in tanks, boilers, or pipelines and cuts power if temperature exceeds the 240°F maximum or drops below the 100°F minimum, preventing equipment damage or unsafe conditions.

What are the specifications of the WHITE-RODGERS 11B18 101S1 immersion controller?

The WHITE-RODGERS 11B18 101S1 immersion controller has a 100°F minimum and 240°F maximum temperature range, with an adjustable differential of 5°F to 45°F. It includes an auto/manual switch, is designed for horizontal mounting, and is a single-function high-limit/low-limit controller. The brand is WHITE-RODGERS.

Where to buy the WHITE-RODGERS immersion controller worldwide?

You can source the WHITE-RODGERS immersion controller through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we supply this controller to industrial clients across multiple regions.

How to install the WHITE-RODGERS immersion controller?

Install the WHITE-RODGERS immersion controller in a horizontal orientation, ensuring the sensing bulb is fully immersed in the process fluid. Wire the auto/manual switch per the manufacturer's diagram. Set the differential between 5°F and 45°F as needed. Always follow local electrical codes and consult a qualified technician for safe installation.

Used in

Common applications for WHITE-RODGERS
Residential furnace replacement — White-Rodgers 767A-377 hot surface igniter for Trane gas furnaces
Commercial HVAC control retrofits — White-Rodgers 90-T60C3 Class 2 transformer for 24V control circuits
Hydronic zone heating systems — White-Rodgers 13 61 104S1 2-way zone valve for multi-zone temperature control
Plenum temperature regulation — White-Rodgers 05D51 035S1 fan and limit control for forced-air furnaces
OEM furnace control board replacement — White-Rodgers 50N02A-820 integrated ignition control for Trane systems
Fan relay and transformer integration — White-Rodgers 90 118ES1 for compact HVAC control panels
Not sure this is the right part? Photo-identify it

WHITE-RODGERS Products

3G Electric supplies WHITE-RODGERS single function. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPST switch, auto reset, and 30°F differential. Opens on temperature rise at 180°F and closes at 150°F. Used in HVAC and industrial heating systems to prevent overheating in furnaces, boilers, and similar equipment
WHITE-RODGERS
WHITE-RODGERS
This surface-mount limit control is a single-pole single-throw (SPST) automatic reset device with a 30°F differential. It opens on temperature rise at 190°F and closes at 160°F, providing over-temperature protection in HVAC and industrial heating systems
WHITE-RODGERS
WHITE-RODGERS
SPST automatic reset limit control with a 30°F differential. Opens on temperature rise at 160°F and closes at 130°F. Surface-mount design for use in HVAC and industrial heating systems to prevent overheating
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, auto reset, and 30°F differential. Opens on temperature rise at 60°F and closes at 40°F. Used in HVAC and industrial heating systems to prevent overheating in ducts, furnaces, or process equipment
WHITE-RODGERS
WHITE-RODGERS
SPST automatic reset limit control with open-on-rise function. Closes at 180°F and opens at 210°F, with a 30°F differential. Surface-mount design for use in HVAC and industrial heating systems to prevent overheating
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, auto reset operation. Opens on temperature rise at 175°F and closes at 135°F. Used for over-temperature protection in HVAC systems, furnaces, boilers, and similar heating equipment

More from WHITE-RODGERS

View all WHITE-RODGERS parts
WHITE-RODGERS
WHITE-RODGERS
Immersion Controller: Circulator/High Limit/Low Limit, 100°F Min, 240°F Max, Horizontal/Vertical (MPN 11 31 102S1)
WHITE-RODGERS
WHITE-RODGERS
Immersion Controller: Circulator/High Limit/Low Limit, 100°F Min, 240°F Max, Horizontal/Vertical (MPN 11D18 001S1)

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first