We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
Image not available
WHITE-RODGERSSurface Mount Limit Controls

WHITE-RODGERS 03L02 200S1 Surface Mount Limit Control

The WHITE-RODGERS Temperature Fan Controller is a surface-mount limit control (SPST, manual reset) that opens on rise at 200°F, operating on 120V AC (MPN 03L02 200S1). 3G Electric interprets customer demand and…

SKU 3G-OTH-69895

Also listed as: 03L02200S1 · 03L02-200S1

Brand
WHITE-RODGERS
Item
03L02 200S1 Surface Mount Limit Control
Part Number
03L02 200S1
Category
Surface Mount Limit Controls
Available to Order
Also known as:03L02 200S1WHITE-RODGERS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

WHITE-RODGERS
Manufacturer Part Number
03L02 200S1
Type
SPST, Manual Reset
AC
120V
Opening
200°F

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WHITE-RODGERS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WHITE-RODGERS Temperature Fan Controller is a surface-mount limit control (SPST, manual reset) that opens on rise at 200°F, operating on 120V AC (MPN 03L02 200S1). 3G Electric interprets customer demand and delivers this genuine industrial control across 14 departments — with specialist depth in combustion, pumps and controls as an authorised distributor — ensuring you get the right answer, not just a catalog.

Frequently Asked Questions

What is the White-Rodgers 03L02 200S1 temperature fan controller used for?

The White-Rodgers 03L02 200S1 is a surface-mount limit control used to shut down a fan or system when temperature exceeds 200°F. It is commonly applied in HVAC equipment, furnaces, and industrial ovens to prevent overheating and protect components.

What are the specifications of the White-Rodgers 03L02 200S1?

The White-Rodgers 03L02 200S1 is a SPST switch that opens on temperature rise, with a 200°F opening setpoint and manual reset. It is rated for 120V AC and is a surface-mount limit control. The manufacturer part number is 03L02 200S1.

Where to buy the White-Rodgers 03L02 200S1 worldwide?

You can source the White-Rodgers 03L02 200S1 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install the White-Rodgers 03L02 200S1 temperature fan controller?

Mount the White-Rodgers 03L02 200S1 securely on a clean surface near the heat source. Wire the SPST switch in series with the fan or load per the wiring diagram. After a trip event, press the manual reset button only after the system cools below the reset threshold.

Used in

Common applications for WHITE-RODGERS
Residential furnace replacement — White-Rodgers 767A-377 hot surface igniter for Trane gas furnaces
Commercial HVAC control retrofits — White-Rodgers 90-T60C3 Class 2 transformer for 24V control circuits
Hydronic zone heating systems — White-Rodgers 13 61 104S1 2-way zone valve for multi-zone temperature control
Plenum temperature regulation — White-Rodgers 05D51 035S1 fan and limit control for forced-air furnaces
OEM furnace control board replacement — White-Rodgers 50N02A-820 integrated ignition control for Trane systems
Fan relay and transformer integration — White-Rodgers 90 118ES1 for compact HVAC control panels
Not sure this is the right part? Photo-identify it

WHITE-RODGERS Products

3G Electric supplies WHITE-RODGERS surface mount limit controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPST switch that opens on temperature rise at 190°F. Manual reset operation. Rated for 120V AC. Used in HVAC systems for fan control or safety shutdown in furnaces, boilers, and heating equipment
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, manual reset, and open-on-rise operation at 160°F. Rated for 120V AC. Used in HVAC systems to interrupt circuit when temperature exceeds setpoint, protecting fans and motors from overheating
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPST switch, auto reset, and open-on-rise action. Opens at 180°F and closes at 140°F. Rated for 120V AC. Used in HVAC systems to regulate fan operation or provide high-temperature limit protection in forced-air furnaces and similar equipment
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPDT switching and automatic reset. Opens on temperature rise at 140°F and closes at 120°F, with a 20°F differential. Used in HVAC systems to regulate fan operation based on temperature
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch that opens on temperature rise at 180°F. Manual reset function restores operation after a high-limit event. Used in HVAC systems for fan control or safety shutdown in furnaces, boilers, and duct heaters
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch that opens on temperature rise at 170°F. Features manual reset for safety shutdown in HVAC systems such as furnaces or boilers

More from WHITE-RODGERS

View all WHITE-RODGERS parts
WHITE-RODGERS
WHITE-RODGERS
This surface-mount limit control is a single-pole single-throw (SPST) automatic reset device with a 30°F differential. It opens on temperature rise at 190°F and closes at 160°F, providing over-temperature protection in HVAC and industrial heating systems
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPST switch and automatic reset. Closes at 250°F and opens at 290°F. Used to monitor and limit temperature in heating equipment such as ovens, furnaces, and process heaters
WHITE-RODGERS
WHITE-RODGERS
This surface-mount limit control from WHITE-RODGERS is a single-pole single-throw (SPST) automatic reset device with a 30°F differential. It opens on temperature rise at 110°F and closes at 80°F, providing over-temperature protection in HVAC and industrial heating systems. Typical applications include furnaces, duct heaters, and other equipment requiring a high-limit safety cutoff
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch and automatic reset. Opens on temperature rise at 200°F and closes at 160°F. Rated for 120V AC. Used in HVAC and heating systems to interrupt power when temperature exceeds the set point
WHITE-RODGERS
WHITE-RODGERS
This surface mount limit control from WHITE-RODGERS features SPST, auto-reset operation. It opens on temperature rise at 215°F and closes at 175°F. Commonly used in HVAC and heating systems for over-temperature protection
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, auto reset operation. Opens on temperature rise at 175°F and closes at 135°F. Used for over-temperature protection in HVAC systems, furnaces, boilers, and similar heating equipment
WHITE-RODGERS
WHITE-RODGERS
SPST automatic reset limit control with a 30°F differential. Opens on temperature rise at 150°F and closes at 120°F. Surface-mount design for over-temperature protection in HVAC and industrial heating systems
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, automatic reset, and 30°F differential. Opens on temperature rise at 250°F and closes at 220°F. Used for over-temperature protection in HVAC and industrial heating systems

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first