We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

VEE GEE Alcoholometer: Alcohol Proof Plain Form, 0/20% Range, 0.2% Scale Divisions - Alcoholometers
VEE GEEAlcoholometers

VEE GEE Alcoholometer: Alcohol Proof Plain Form, 0/20% Range, 0.2% Scale Divisions

The VEE GEE Alcoholometer: Alcohol Proof Plain Form (SKU 55EZ33, MPN 6613-F) is a glass hydrometer with +/-0.3% accuracy, a 0/20% range, and 0.2% scale divisions. It features an Alcohol Proof Plain Form scale type…

SKU 3G-OTH-638357

Brand
VEE GEE
Item
Alcoholometer: Alcohol Proof Plain Form, 0/20% Range, 0.2% Scale Divisions
Category
Alcoholometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

VEE GEE
Manufacturer Part Number
6613-F
Type
Glass, +/-0.3% Accuracy
Range
0/20%
Scale Type
Alcohol Proof Plain Form
Scale Divisions
0.2%
Hydrometer Internal Revenue Code
F
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

VEE GEE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The VEE GEE Alcoholometer: Alcohol Proof Plain Form (SKU 55EZ33, MPN 6613-F) is a glass hydrometer with +/-0.3% accuracy, a 0/20% range, and 0.2% scale divisions. It features an Alcohol Proof Plain Form scale type and carries Hydrometer Internal Revenue Code F.

Frequently Asked Questions

What is a VEE GEE Alcoholometer 0/20% used for?

This VEE GEE Alcoholometer measures alcohol proof in distilled spirits within a 0/20% range. It is used by distilleries, quality control labs, and regulatory inspectors to verify ethanol concentration per U.S. Internal Revenue Code F. The glass hydrometer provides ±0.3% accuracy for compliance and blending applications.

What are the specifications of the VEE GEE Alcoholometer 6613-F?

The VEE GEE Alcoholometer (MPN 6613-F) has a 0/20% range with 0.2% scale divisions and ±0.3% accuracy. It is a glass hydrometer with an Alcohol Proof Plain Form scale and Hydrometer Internal Revenue Code F. The SKU is 55EZ33. These specs ensure precise proof measurement for distilled spirits.

Where to buy a VEE GEE Alcoholometer 0/20% worldwide?

3G Electric supplies the VEE GEE Alcoholometer 0/20% (SKU 55EZ33) to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this glass hydrometer with ±0.3% accuracy.

How to use a VEE GEE Alcoholometer for proof measurement?

To use the VEE GEE Alcoholometer, fill a clean hydrometer jar with the spirit sample at the calibrated temperature (typically 60°F). Gently lower the glass hydrometer and spin to release bubbles. Read the scale at the bottom of the meniscus. The 0.2% divisions allow precise proof determination per Internal Revenue Code F.

Used in

Common applications for VEE GEE
Food and beverage quality control — VEE GEE Brix refractometers (e.g., MPN 43007) for measuring sugar content in juices and syrups.
Chemical concentration monitoring — VEE GEE digital refractometers (e.g., MPN 48301) for Baume and refractive index analysis in industrial fluids.
Soil temperature monitoring in agriculture — VEE GEE soil dial thermometers (e.g., MPN 82160-12) for checking soil conditions before planting.
Compost pile temperature tracking — VEE GEE compost dial thermometers (e.g., MPN 82200-48) for managing decomposition processes.
Laboratory refractive index measurement — VEE GEE benchtop refractometers (e.g., MPN C10) for precise Brix and RI analysis in research settings.
Industrial process temperature checks — VEE GEE digital pocket thermometers (e.g., MPN 83210-12) for quick temperature readings in HVAC or manufacturing.

VEE GEE Products

3G Electric supplies VEE GEE alcoholometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from VEE GEE

View all VEE GEE parts
Alcoholometer: Alcohol Proof Plain Form, 185/206% Range, 0.2% Scale Divisions, Glass, +/-0.2 (MPN 6613-R). Key specifications — Hydrometer Internal Revenue Code: R; Range: 185/206%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 185/206% Range, 0.2% Scale Divisions, Glass, +/-0.2 (MPN 6613-R). Key specifications — Hydrometer Internal Revenue Code: R; Range: 185/206%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 90/110% Range, 0.2% Scale Divisions, Glass (MPN 6613-L). Key specifications — Hydrometer Internal Revenue Code: L; Range: 90/110%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 90/110% Range, 0.2% Scale Divisions, Glass (MPN 6613-L). Key specifications — Hydrometer Internal Revenue Code: L; Range: 90/110%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 40/60% Range, 0.2% Scale Divisions, Glass, +/-0.4% Accuracy (MPN 6613-H). Key specifications — Hydrometer Internal Revenue Code: H; Range: 40/60%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 40/60% Range, 0.2% Scale Divisions, Glass, +/-0.4% Accuracy (MPN 6613-H). Key specifications — Hydrometer Internal Revenue Code: H; Range: 40/60%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 105/125% Range, 0.2% Scale Divisions, Glass (MPN 6613-M). Key specifications — Hydrometer Internal Revenue Code: M; Range: 105/125%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 105/125% Range, 0.2% Scale Divisions, Glass (MPN 6613-M). Key specifications — Hydrometer Internal Revenue Code: M; Range: 105/125%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 165/185% Range, 0.2% Scale Divisions, Glass (MPN 6613-Q). Key specifications — Hydrometer Internal Revenue Code: Q; Range: 165/185%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 165/185% Range, 0.2% Scale Divisions, Glass (MPN 6613-Q). Key specifications — Hydrometer Internal Revenue Code: Q; Range: 165/185%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 60/80% Range, 0.2% Scale Divisions, Glass, +/-0.3% Accuracy (MPN 6613-I). Key specifications — Hydrometer Internal Revenue Code: I; Range: 60/80%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 60/80% Range, 0.2% Scale Divisions, Glass, +/-0.3% Accuracy (MPN 6613-I). Key specifications — Hydrometer Internal Revenue Code: I; Range: 60/80%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 80/120% Range, 0.5% Scale Divisions, Glass (MPN 6613-B). Key specifications — Hydrometer Internal Revenue Code: B; Range: 80/120%; Scale Divisions: 0.5%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 80/120% Range, 0.5% Scale Divisions, Glass (MPN 6613-B). Key specifications — Hydrometer Internal Revenue Code: B; Range: 80/120%; Scale Divisions: 0.5%; Scale Type: Alcohol Proof Plain Form.
Alcoholometer: Alcohol Proof Plain Form, 20/40% Range, 0.2% Scale Divisions, Glass, +/-0.4% Accuracy (MPN 6613-G). Key specifications — Hydrometer Internal Revenue Code: G; Range: 20/40%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.
VEE GEE
Alcoholometer: Alcohol Proof Plain Form, 20/40% Range, 0.2% Scale Divisions, Glass, +/-0.4% Accuracy (MPN 6613-G). Key specifications — Hydrometer Internal Revenue Code: G; Range: 20/40%; Scale Divisions: 0.2%; Scale Type: Alcohol Proof Plain Form.