The TRACXP Calibration Gas TXP-T40 (SKU TXP-CAL-C2H2-50LEL, MPN TXP-CAL-C2H2-50LEL) is a 105 L cylinder of acetylene (50% LEL) at 1.25% in an air background, designed for calibrating TXP-T40 fixed gas detectors. This…

SKU 3G-OTH-551844

Also listed as: TXPCALC2H250LEL · TXP CAL C2H2 50LEL

Brand
TRACXP
Item
TXP-CAL-C2H2-50LEL Calibration Gas
Category
Calibration Gases for Fixed Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

TRACXP
Manufacturer Part Number
TXP-CAL-C2H2-50LEL
Type
Air, Cylinder, Acetylene, C2H2
Gas Mixture
Acetylene (50% LEL) 1.25%
For Use With
TXP-T40
Product Type
Calibration Gas
Background Gas
Air
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TRACXP Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The TRACXP Calibration Gas TXP-T40 (SKU TXP-CAL-C2H2-50LEL, MPN TXP-CAL-C2H2-50LEL) is a 105 L cylinder of acetylene (50% LEL) at 1.25% in an air background, designed for calibrating TXP-T40 fixed gas detectors. This calibration gas is supplied by 3G Electric, a global industrial solutions provider that interprets customer demand and delivers genuine equipment across 14 industrial departments — with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is TRACXP TXP-CAL-C2H2-50LEL calibration gas used for?

The TRACXP TXP-CAL-C2H2-50LEL calibration gas is used to calibrate TXP-T40 fixed gas detectors. It contains acetylene at 1.25% (50% LEL) in an air background, ensuring accurate sensor response for combustible gas monitoring in industrial safety applications.

What are the specifications of TRACXP TXP-CAL-C2H2-50LEL?

The TRACXP TXP-CAL-C2H2-50LEL is a 105 L cylinder with a gas mixture of acetylene (50% LEL) at 1.25% in an air background. It is designed for use with TXP-T40 fixed gas detectors and is supplied as a calibration gas by 3G Electric.

Where to buy TRACXP calibration gas TXP-CAL-C2H2-50LEL worldwide?

3G Electric supplies the TRACXP TXP-CAL-C2H2-50LEL calibration gas worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this acetylene calibration cylinder to your facility, supporting fixed gas detector calibration programs.

How to use TRACXP TXP-CAL-C2H2-50LEL for calibrating TXP-T40?

To calibrate a TXP-T40 detector with TRACXP TXP-CAL-C2H2-50LEL, connect the cylinder regulator to the detector's calibration port, release gas at the specified flow rate, and follow the detector's calibration procedure. Always use in a well-ventilated area and dispose of cylinders per local regulations.

TRACXP Products

3G Electric supplies TRACXP calibration gases for fixed gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GASCO calibration gas cylinder containing propane mixture (20.9% LEL, 0.44%) in air background with +/-2% accuracy. Cylinder capacity is 105 L. Used for verifying and adjusting the accuracy of portable and fixed gas detectors in industrial safety applications
GASCO
GASCO calibration gas cylinder containing propane mixture (20.9% LEL, 0.44%) in air background with +/-2% accuracy. Cylinder capacity is 105 L. Used for verifying and adjusting the accuracy of portable and fixed gas detectors in industrial safety applications
This calibration gas cylinder contains a certified propane mixture of 6220 ppm (30% LEL) in an air background, with ±2% accuracy. The 105 L cylinder is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications
GASCO
This calibration gas cylinder contains a certified propane mixture of 6220 ppm (30% LEL) in an air background, with ±2% accuracy. The 105 L cylinder is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications
This calibration gas cylinder contains a propane mixture at 25% LEL (0.525%) with air as the background gas. It provides +/-2% accuracy and has a 105 L capacity. Used for verifying and adjusting the response of portable and fixed gas detectors in industrial safety applications
GASCO
This calibration gas cylinder contains a propane mixture at 25% LEL (0.525%) with air as the background gas. It provides +/-2% accuracy and has a 105 L capacity. Used for verifying and adjusting the response of portable and fixed gas detectors in industrial safety applications
Calibration gas cylinder containing Propane (35.7% LEL) 7,500 ppm in Air background gas. ±2% accuracy. 105 L capacity. For use with all OEM portable gas detectors to verify sensor response and accuracy
GASCO
Calibration gas cylinder containing Propane (35.7% LEL) 7,500 ppm in Air background gas. ±2% accuracy. 105 L capacity. For use with all OEM portable gas detectors to verify sensor response and accuracy
Calibration gas cylinder containing 0.97% propane (46% LEL) in air, with +/-2% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify and adjust sensor readings
GASCO
Calibration gas cylinder containing 0.97% propane (46% LEL) in air, with +/-2% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify and adjust sensor readings
GASCO calibration gas cylinder with +/-2% accuracy, containing Propane (17% LEL) at 0.35% concentration in an Air background. The 105 L cylinder is used for verifying and calibrating portable gas detectors in industrial safety applications, compatible with all OEM gas detectors
GASCO
GASCO calibration gas cylinder with +/-2% accuracy, containing Propane (17% LEL) at 0.35% concentration in an Air background. The 105 L cylinder is used for verifying and calibrating portable gas detectors in industrial safety applications, compatible with all OEM gas detectors

More from TRACXP

View all TRACXP parts
Calibration gas mixture of 2% hydrogen (50% LEL) in air, supplied in a 105 L cylinder. Used to verify and adjust the accuracy of fixed gas detectors in industrial safety applications
TRACXP
Calibration gas mixture of 2% hydrogen (50% LEL) in air, supplied in a 105 L cylinder. Used to verify and adjust the accuracy of fixed gas detectors in industrial safety applications
Calibration gas cylinder containing Methane (50% LEL) 2.5% in an Air background, with a capacity of 105 L. Designed for use with TRACXP TXP-T40 fixed gas detectors to verify sensor accuracy for methane detection in industrial safety applications
TRACXP
Calibration gas cylinder containing Methane (50% LEL) 2.5% in an Air background, with a capacity of 105 L. Designed for use with TRACXP TXP-T40 fixed gas detectors to verify sensor accuracy for methane detection in industrial safety applications
This calibration gas cylinder contains Propane (C3H8) at 25% LEL in an Air background, with a 103 L capacity. It is used to verify and calibrate fixed gas detectors, ensuring accurate sensor response for combustible gas monitoring in industrial safety applications
TRACXP
This calibration gas cylinder contains Propane (C3H8) at 25% LEL in an Air background, with a 103 L capacity. It is used to verify and calibrate fixed gas detectors, ensuring accurate sensor response for combustible gas monitoring in industrial safety applications
Calibration gas mixture containing 50% methane (CH4) balanced with nitrogen, supplied in a 105 L cylinder. Used to verify and calibrate fixed gas detectors that measure methane, ensuring accurate sensor response in industrial safety applications
TRACXP
Calibration gas mixture containing 50% methane (CH4) balanced with nitrogen, supplied in a 105 L cylinder. Used to verify and calibrate fixed gas detectors that measure methane, ensuring accurate sensor response in industrial safety applications
This calibration gas cylinder contains a mixture of 100 ppm carbon monoxide in an air background. It is used for verifying and calibrating fixed gas detectors, ensuring accurate sensor response in industrial safety applications. Cylinder capacity is 58 liters
TRACXP
This calibration gas cylinder contains a mixture of 100 ppm carbon monoxide in an air background. It is used for verifying and calibrating fixed gas detectors, ensuring accurate sensor response in industrial safety applications. Cylinder capacity is 58 liters
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 58 L Cylinder Capacity, Hydrogen Sulfide 250 ppm (MPN TXP-CAL-H2S-250PPM)
TRACXP
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 58 L Cylinder Capacity, Hydrogen Sulfide 250 ppm (MPN TXP-CAL-H2S-250PPM)
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 105 L Cylinder Capacity, Isobutylene 100 ppm, C4H8 (MPN TXP-CAL-C4H8-100PPM)
TRACXP
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 105 L Cylinder Capacity, Isobutylene 100 ppm, C4H8 (MPN TXP-CAL-C4H8-100PPM)
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 58 L Cylinder Capacity, Hydrogen Sulfide 100 ppm (MPN TXP-CAL-H2S-100PPM)
TRACXP
TRACXP Calibration Gas: TXP-T40, Air, Cylinder, 58 L Cylinder Capacity, Hydrogen Sulfide 100 ppm (MPN TXP-CAL-H2S-100PPM)