STA-KON Butt Splice Connector: Bare, For Wire Size 22 AWG – 18 AWG, 600 V
The STA-KON Butt Splice Connector is a non-insulated connector for wire sizes 22 AWG to 18 AWG, rated at 600 V, and sold in packs of 100 (MPN 2A-18). 3G Electric sources this genuine STA-KON component as part of our…
SKU 3G-OTH-18093
Also listed as: 2A18 · 2A 18
Local availability & support
- Delivery
- Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
- Payment
- Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.
Need installation or engineering help?
Ask a question
Product Description
The STA-KON Butt Splice Connector is a non-insulated connector for wire sizes 22 AWG to 18 AWG, rated at 600 V, and sold in packs of 100 (MPN 2A-18). 3G Electric sources this genuine STA-KON component as part of our broader electrical supply capability across 14 industrial departments, with specialist depth in controls and automation.
Frequently Asked Questions
What is a STA-KON butt splice connector used for?
A STA-KON butt splice connector joins two wires end-to-end in electrical systems. It is used across industrial maintenance, panel building, and repair applications where reliable, low-resistance connections are needed for 22 AWG to 18 AWG wire.
What are the specifications of the STA-KON 2A-18 butt splice connector?
The STA-KON 2A-18 is a non-insulated butt splice connector rated for 600 V and wire sizes 22 AWG to 18 AWG. It comes in a pack quantity of 100. The bare design allows for custom insulation or use in tight spaces.
Where to buy STA-KON butt splice connectors worldwide?
3G Electric supplies STA-KON butt splice connectors worldwide. As a global industrial sourcing partner, we handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on the 2A-18 or other STA-KON terminals.
How to install a non-insulated butt splice connector?
Strip 1/4 to 3/8 inch of insulation from each wire end. Insert one wire into each end of the STA-KON splice. Use a crimping tool matched to 22-18 AWG to compress the barrel firmly. Pull-test each connection to verify mechanical strength before applying heat shrink or tape.
Used in
Common applications for STA-KONSTA-KON Products
3G Electric supplies STA-KON non-insulated butt splice connectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.
You might also need
Related products
- AVENTICS AVENTICS Manual Air Control Valve: Panel, Five-Way / Two-Position, Stainless Steel, Spool, 145 psi (MPN R422002213)
- AVENTICS AVENTICS Manual Air Control Valve: Panel, Three-Way / Two-Position, Stainless Steel, Spool, 145 psi (MPN R422002211)
- AVENTICS AVENTICS Solenoid Coil Connector: DIN 43650 Form B, 250V AC/300V DC, 2 Pin, Indicator Light Included (MPN 1834484096)
- AVENTICS AVENTICS Manual Air Control Valve: Plunger, Three-Way / Two-Position, Stainless Steel, 1/8 in BSPP (MPN 0820402001)
- AVENTICS AVENTICS Adapter Kit: AP/ST, Adapter Kit (MPN R422002219)
- AVENTICS AVENTICS Solenoid Coil Connector (MPN R432015626)