EXW Singapore — collect or forward from our Singapore office.

3G Electric
SQUARE D 8911DPSG43V06 Enclosed Non-Reversing Starter with - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8911DPSG43V06 Enclosed Non-Reversing Starter with

The SQUARE D Definite Purpose Magnetic Motor Starter is a non-reversing enclosed starter with thermal overloads, rated for 3 poles, 40 A, and a 480V AC coil (MPN 8911DPSG43V06). It requires 3 thermal units (not…

SKU 3G-OTH-42802

Brand
SQUARE D
Item
8911DPSG43V06 Enclosed Non-Reversing Starter with
Part Number
8911DPSG43V06
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8911DPSG43V06SQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8911DPSG43V06
Type
40 A, SQD145
Poles
3
AC Coil
480V
Thermal Units Required
3 Thermal Units Required (Not Included)

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Definite Purpose Magnetic Motor Starter is a non-reversing enclosed starter with thermal overloads, rated for 3 poles, 40 A, and a 480V AC coil (MPN 8911DPSG43V06). It requires 3 thermal units (not included) for overload protection.

Frequently Asked Questions

What is the SQUARE D Definite Purpose Magnetic Motor Starter used for?

This starter is used to control and protect motors in industrial applications such as HVAC, pumps, and conveyors. It provides non-reversing motor starting with thermal overload protection, requiring three thermal units (not included) to prevent motor damage from overcurrent.

What are the specifications of the SQUARE D 8911DPSG43V06 starter?

The SQUARE D 8911DPSG43V06 is a definite purpose magnetic motor starter with 3 poles, 40 A rating, and a 480V AC coil. It is an enclosed non-reversing starter with thermal overloads and requires 3 thermal units (not included) for overload protection.

Where to buy the SQUARE D 8911DPSG43V06 starter worldwide?

You can source the SQUARE D 8911DPSG43V06 starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring reliable supply for your motor control needs.

How to select thermal units for the SQUARE D 8911DPSG43V06 starter?

Select thermal units based on the full-load current of your motor. The SQUARE D starter requires 3 thermal units (not included) for overload protection. Consult the motor nameplate and SQUARE D thermal unit selection charts to match the correct heater element for your application.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from SQUARE D

View all SQUARE D parts →
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first