3G Electric
SQUARE D 8536SEG1V06 Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SEG1V06 Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is a non-reversing, enclosed starter with thermal overloads, featuring three poles and NEMA Size 3 rating at 90 A. It operates on a 480V AC coil voltage and three-phase power, with…

SKU 3G-OTH-41676

Brand
SQUARE D
Item
8536SEG1V06 Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SEG1V06
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SEG1V06SQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SEG1V06
Type
NEMA Size 3, 90 A
Phase
Three
Poles
3
AC Coil
480V
Operator
None
Coil Voltage
480V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
3 Melting Alloy Units (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is a non-reversing, enclosed starter with thermal overloads, featuring three poles and NEMA Size 3 rating at 90 A. It operates on a 480V AC coil voltage and three-phase power, with screw clamp terminals and no operator controls, pilot light, or auxiliary contacts. Three melting alloy thermal units are required but not included.

Frequently Asked Questions

What is the SQUARE D 8536SEG1V06 magnetic motor starter used for?

The SQUARE D 8536SEG1V06 is an enclosed non-reversing magnetic motor starter with thermal overloads, designed to start and protect three-phase motors in industrial applications such as conveyors, pumps, and compressors. It requires three melting alloy thermal units (not included) for overload protection.

What are the specifications of the SQUARE D 8536SEG1V06 starter?

This SQUARE D starter is NEMA Size 3 rated at 90 A, with three poles, a 480V AC coil voltage, and three-phase power. It features screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. The manufacturer part number is 8536SEG1V06.

Where to buy the SQUARE D 8536SEG1V06 worldwide?

3G Electric supplies the SQUARE D 8536SEG1V06 magnetic motor starter worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to select thermal units for the SQUARE D 8536SEG1V06 starter?

Select three melting alloy thermal units based on the full-load current rating of your motor. The SQUARE D 8536SEG1V06 requires these units (not included) for overload protection. Consult the motor nameplate and SQUARE D thermal unit selection tables to match the correct heater size.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from SQUARE D

View all SQUARE D parts →
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first