We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
SQUARE D 8536SEG1V02S Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SEG1V02S Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, part number 8536SEG1V02S. It is a three-phase, NEMA Size 3 unit rated at 90 A with a 110/120V AC coil voltage. This…

SKU 3G-OTH-41608

Brand
SQUARE D
Item
8536SEG1V02S Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SEG1V02S
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SEG1V02SSQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SEG1V02S
Type
NEMA Size 3, 90 A
Phase
Three
Poles
3
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
3 Melting Alloy Units (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, part number 8536SEG1V02S. It is a three-phase, NEMA Size 3 unit rated at 90 A with a 110/120V AC coil voltage. This starter features screw clamp terminals and requires three melting alloy thermal units (not included) for overload protection. It includes no operator controls, pilot light, or auxiliary contacts.

Frequently Asked Questions

What is the SQUARE D 8536SEG1V02S magnetic motor starter used for?

The SQUARE D 8536SEG1V02S is an enclosed non-reversing magnetic motor starter used to start and stop three-phase motors in industrial applications such as conveyors, pumps, and compressors. It provides overload protection via three melting alloy thermal units (not included) and is rated NEMA Size 3, 90 A, with a 120V AC coil.

What are the specifications of the SQUARE D 8536SEG1V02S starter?

The SQUARE D 8536SEG1V02S is a NEMA Size 3, 90 A, three-phase, non-reversing magnetic motor starter with a 110/120V AC coil voltage. It has 3 poles, screw clamp terminals, and requires three melting alloy thermal units (not included) for overload protection. No operator controls, pilot light, or auxiliary contacts are included.

Where to buy the SQUARE D 8536SEG1V02S magnetic motor starter worldwide?

3G Electric supplies the SQUARE D 8536SEG1V02S magnetic motor starter to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this NEMA Size 3, 90 A, 120V AC coil starter.

How to select thermal units for the SQUARE D 8536SEG1V02S starter?

To select thermal units for the SQUARE D 8536SEG1V02S starter, match the melting alloy heater element to the full-load current of your three-phase motor. The starter requires three melting alloy thermal units (not included) for overload protection. Consult the motor nameplate and SQUARE D heater selection tables to choose the correct size.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems
Not sure this is the right part? Photo-identify it

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts

Customer reviews

No reviews yet — be the first

Questions & answers