EXW Singapore — collect or forward from our Singapore office.

3G Electric
SQUARE D 8536SDA1V02S Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SDA1V02S Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is a non-reversing, enclosed starter with thermal overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 110/120V AC coil, with screw…

SKU 3G-OTH-42120

Brand
SQUARE D
Item
8536SDA1V02S Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SDA1V02S
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SDA1V02SSQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SDA1V02S
Type
NEMA Size 2, 45 A
Phase
Three
Poles
3
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
3 Melting Alloy Units (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is a non-reversing, enclosed starter with thermal overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 110/120V AC coil, with screw clamp terminals for secure wiring. It requires three melting alloy thermal units (not included) and includes no operator controls, pilot light, or auxiliary contacts.

Frequently Asked Questions

What is the SQUARE D 8536SDA1V02S magnetic motor starter used for?

The SQUARE D 8536SDA1V02S is a NEMA Size 2, 45 A non-reversing enclosed starter with thermal overloads, used to start and protect three-phase motors in industrial applications such as conveyors, pumps, and compressors. It requires three melting alloy thermal units (not included) and operates on a 110/120V AC coil.

What are the specifications of the SQUARE D 8536SDA1V02S starter?

This SQUARE D starter is NEMA Size 2, rated 45 A, with 3 poles and a 110/120V AC coil. It has screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. It requires three melting alloy thermal units (not included) for overload protection. The part number is 8536SDA1V02S.

Where to buy the SQUARE D 8536SDA1V02S starter worldwide?

3G Electric supplies the SQUARE D 8536SDA1V02S magnetic motor starter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this NEMA Size 2, 45 A starter with 120V AC coil.

How to select thermal units for the SQUARE D 8536SDA1V02S starter?

To select melting alloy thermal units for the SQUARE D 8536SDA1V02S, match the motor full-load current to the appropriate SQUARE D thermal unit heater element. The starter requires three units (not included). Refer to the motor nameplate and SQUARE D selection tables to ensure proper overload protection for your three-phase application.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from SQUARE D

View all SQUARE D parts →
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first