The SQUARE D Magnetic Motor Starter is a non-reversing starter with thermal overloads, part number 8536SBO1V02ES. This single-phase unit features a 110/120V AC coil, NEMA Size 0 rating, 18 A capacity, and 2 poles. It…

SKU 3G-OTH-40581

Brand
SQUARE D
Item
8536SBO1V02ES Non-Reversing Starter with Thermal Overloads
Part Number
8536SBO1V02ES
Category
Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SBO1V02ESSQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SBO1V02ES
Type
NEMA Size 0, 18 A
Phase
Single
Poles
2
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
None (Includes Integrated Bimetallic Elements)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is a non-reversing starter with thermal overloads, part number 8536SBO1V02ES. This single-phase unit features a 110/120V AC coil, NEMA Size 0 rating, 18 A capacity, and 2 poles. It includes integrated bimetallic elements for overload protection and uses screw clamp terminals, with no operator, pilot light, or auxiliary contacts.

Frequently Asked Questions

What is the SQUARE D 8536SBO1V02ES magnetic motor starter used for?

The SQUARE D 8536SBO1V02ES is a non-reversing magnetic motor starter used to start and stop single-phase AC motors in industrial applications such as conveyors, pumps, and fans. It provides overload protection via integrated bimetallic elements, making it suitable for motor control centers and standalone equipment.

What are the specifications of the SQUARE D 8536SBO1V02ES starter?

This SQUARE D starter is NEMA Size 0, rated 18 A, with 2 poles and a 110/120V AC coil. It is single-phase, non-reversing, and includes integrated bimetallic thermal overloads. Terminal connections are screw clamp type. No operator, pilot light, or auxiliary contacts are included.

Where to buy the SQUARE D 8536SBO1V02ES worldwide?

3G Electric supplies the SQUARE D 8536SBO1V02ES magnetic motor starter worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this SQUARE D part to any country.

How to select the correct thermal overload for a SQUARE D NEMA Size 0 starter?

The SQUARE D 8536SBO1V02ES includes integrated bimetallic elements, so no separate thermal units are required. For selection, match the motor full-load current to the starter's 18 A rating. Ensure coil voltage (110/120V AC) matches your control circuit. Consult the motor nameplate for proper sizing.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from SQUARE D

View all SQUARE D parts →
Non-reversing magnetic motor starter with thermal overloads, rated 30 A, 3 poles, and 208-240V AC coil. Requires three thermal units (sold separately) for overload protection. Suitable for starting and protecting 3-phase motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Non-reversing magnetic motor starter with thermal overloads, rated 30 A, 3 poles, and 208-240V AC coil. Requires three thermal units (sold separately) for overload protection. Suitable for starting and protecting 3-phase motors in applications such as HVAC, pumps, and conveyors
Non-reversing manual motor starter with thermal overload protection. Rated 27 A, 3 poles, NEMA Size M-1, maximum 600V AC. Requires 3 thermal units (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
SQUARE D
Non-reversing manual motor starter with thermal overload protection. Rated 27 A, 3 poles, NEMA Size M-1, maximum 600V AC. Requires 3 thermal units (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 1 rated 27 A, 3 poles, 110/120V AC coil. Includes integrated bimetallic thermal overload elements for motor protection. Screw clamp terminals. Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
SQUARE D
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 1 rated 27 A, 3 poles, 110/120V AC coil. Includes integrated bimetallic thermal overload elements for motor protection. Screw clamp terminals. Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
Three-pole NEMA Size 0 non-reversing starter rated 18 A with 110/120V AC coil. Includes integrated bimetallic overload elements for motor protection. Screw clamp terminals. No auxiliary contacts, operator controls, or pilot light. Suitable for controlling three-phase motors in applications such as conveyors, pumps, compressors, and fans
SQUARE D
Three-pole NEMA Size 0 non-reversing starter rated 18 A with 110/120V AC coil. Includes integrated bimetallic overload elements for motor protection. Screw clamp terminals. No auxiliary contacts, operator controls, or pilot light. Suitable for controlling three-phase motors in applications such as conveyors, pumps, compressors, and fans

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first