We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
SQUARE D Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, featuring a 110/120V AC coil and three-phase operation. This NEMA Size 00 unit is rated for 9 A and includes screw…

SKU 3G-OTH-41226

Brand
SQUARE D
Item
Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SAG12V02S
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SAG12V02SSQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SAG12V02S
Type
NEMA Size 00, 9 A
Phase
Three
Poles
3
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
3 Melting Alloy Units (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, featuring a 110/120V AC coil and three-phase operation. This NEMA Size 00 unit is rated for 9 A and includes screw clamp terminals, with no operator controls, pilot light, or auxiliary contacts. Three melting alloy thermal units are required but not included.

Frequently Asked Questions

What is the SQUARE D 8536SAG12V02S magnetic motor starter used for?

The SQUARE D 8536SAG12V02S is an enclosed non-reversing magnetic motor starter used to start and stop three-phase motors in industrial applications such as conveyors, pumps, and fans. It provides overload protection via three melting alloy thermal units (not included) and is suitable for NEMA Size 00 installations up to 9 A.

What are the specifications of the SQUARE D 8536SAG12V02S starter?

This SQUARE D starter is NEMA Size 00, rated 9 A, with 3 poles and a 110/120V AC coil. It features screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. Three melting alloy thermal units are required but not included. The MPN is 8536SAG12V02S.

Where to buy the SQUARE D 8536SAG12V02S worldwide?

You can source the SQUARE D 8536SAG12V02S magnetic motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide competitive pricing and reliable sourcing.

How to select thermal units for the SQUARE D 8536SAG12V02S starter?

To select thermal units for this SQUARE D starter, match the melting alloy unit's trip current to the full-load amperage of your three-phase motor. The starter requires three units (not included) and accepts SQUARE D melting alloy heaters. Consult the motor nameplate and SQUARE D selection tables for the correct heater class and rating.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from SQUARE D

View all SQUARE D parts →
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first