SQUARE D Molded Case Circuit Breaker: 60 A Amps, 100kA at 120/240V AC, Fixed - B-Frame Square D Molded Case Circuit Breakers
SQUARE DB-Frame Square D Molded Case Circuit Breakers

SQUARE D Molded Case Circuit Breaker: 60 A Amps, 100kA at 120/240V AC, Fixed

The Square D B-Frame Molded Case Circuit Breaker (MPN BJL36060) is a 60 A, 100kA at 120/240V AC device with a fixed instantaneous trip, Everlink Lug connections at both ends, and ABC phase connection. It is part of…

SKU 3G-OTH-721918

Brand
SQUARE D
Item
Molded Case Circuit Breaker: 60 A Amps, 100kA at 120/240V AC, Fixed
Category
B-Frame Square D Molded Case Circuit Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SQUARE D
Manufacturer Part Number
BJL36060
Series
BJL
Type
100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, ABC
Max. AIR Rating
100kA at 120/240V AC
Phase Connection
ABC
Instantaneous Trip
Fixed
Terminal Connection
Everlink Lug Both Ends
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Square D B-Frame Molded Case Circuit Breaker (MPN BJL36060) is a 60 A, 100kA at 120/240V AC device with a fixed instantaneous trip, Everlink Lug connections at both ends, and ABC phase connection. It is part of the BJL series, designed for reliable overcurrent protection in industrial electrical distribution.

Frequently Asked Questions

What is the Square D BJL36060 molded case circuit breaker used for?

The Square D BJL36060 is a 60 A molded case circuit breaker used for overcurrent protection in industrial electrical distribution. It features a 100kA interrupting rating at 120/240V AC, fixed instantaneous trip, and Everlink Lug connections, making it suitable for branch circuit protection in commercial and industrial panels.

What are the specifications of the Square D BJL36060 circuit breaker?

The Square D BJL36060 is a 60 A, B-Frame molded case circuit breaker with a 100kA maximum AIR rating at 120/240V AC. It has a fixed instantaneous trip, ABC phase connection, and Everlink Lug terminals on both ends. It is part of the BJL series and is designed for reliable overcurrent protection.

Where to buy the Square D BJL36060 circuit breaker worldwide?

3G Electric supplies the Square D BJL36060 molded case circuit breaker worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this 60 A, 100kA breaker with Everlink Lug connections to your facility. Contact us for availability and lead time.

How to install the Square D BJL36060 circuit breaker?

Install the Square D BJL36060 by ensuring the panel is de-energized, then mount the breaker onto the bus bars. Torque the Everlink Lug terminals to the manufacturer's recommended value for 60 A conductors. Verify the fixed instantaneous trip setting matches your application. Always follow local electrical codes and the Square D installation manual.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D b-frame square d molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts
Molded Case Circuit Breaker: 30 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, Any (MPN BJL16030). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Any; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
SQUARE D
Molded Case Circuit Breaker: 30 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, Any (MPN BJL16030). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Any; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260501). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
SQUARE D
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260501). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, 2 Poles (MPN BDL26050LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Non-Applicable; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
SQUARE D
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, 2 Poles (MPN BDL26050LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Non-Applicable; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
Molded Case Circuit Breaker: 100 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BDL36100). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
SQUARE D
Molded Case Circuit Breaker: 100 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BDL36100). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
Molded Case Circuit Breaker: 70 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260701). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
SQUARE D
Molded Case Circuit Breaker: 70 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260701). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
Molded Case Circuit Breaker: 45 A Amps, 100kA at 240V AC, Fixed, ABC, 3 Poles, 525V AC, BGA (MPN BGA34045Y). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGA.
SQUARE D
Molded Case Circuit Breaker: 45 A Amps, 100kA at 240V AC, Fixed, ABC, 3 Poles, 525V AC, BGA (MPN BGA34045Y). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGA.
Molded Case Circuit Breaker: 70 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BJL36070LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
SQUARE D
Molded Case Circuit Breaker: 70 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BJL36070LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
Molded Case Circuit Breaker: 35 A Amps, 100kA at 240V AC, Fixed, Everlink Lug Both Ends, ABC, BGL (MPN BGL36035). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGL.
SQUARE D
Molded Case Circuit Breaker: 35 A Amps, 100kA at 240V AC, Fixed, Everlink Lug Both Ends, ABC, BGL (MPN BGL36035). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGL.