We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

SQUARE D Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers - Square D QO - Main Lug Load Centers
SQUARE DSquare D QO - Main Lug Load Centers

SQUARE D Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers

The Square D QO Main Lug Load Center (MPN QO330L200GRB) is a 200 A, 3-phase, 30-space outdoor unit rated at 208Y/120/240V AC with a 65kA short-circuit current rating. It includes a surface cover and supports zero…

SKU 3G-OTH-609692

Brand
SQUARE D
Item
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers
Category
Square D QO - Main Lug Load Centers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SQUARE D
Manufacturer Part Number
QO330L200GRB
Type
65kA, Outdoor
AC
208Y/120/240V
Phase
3
Spaces
30
Voltage
208Y/120/240V AC
Location
Outdoor
Included Enclosure Cover
Surface Cover
Max. No. Of Tandem Breakers
0
Short Circuit Current Rating
65kA
Main Circuit Breaker or Main Lug
Main Lug
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Square D QO Main Lug Load Center (MPN QO330L200GRB) is a 200 A, 3-phase, 30-space outdoor unit rated at 208Y/120/240V AC with a 65kA short-circuit current rating. It includes a surface cover and supports zero tandem breakers, making it a grounded solution for commercial or industrial branch-circuit distribution.

Frequently Asked Questions

What is the Square D QO330L200GRB load center used for?

The Square D QO330L200GRB is a 200 A, 3-phase main lug load center for outdoor commercial or industrial branch-circuit distribution. It distributes power from a separate main breaker at 208Y/120/240V AC with a 65kA short-circuit rating, supporting up to 30 circuits.

What are the specifications of the Square D QO330L200GRB?

This Square D QO load center is rated 200 A, 208Y/120/240V AC, 3-phase, 65kA SCCR, with 30 spaces and zero tandem breaker capacity. It includes a surface cover, is for outdoor use, and is configured as a main lug unit requiring a separate upstream main breaker.

Where to buy the Square D QO330L200GRB load center worldwide?

3G Electric supplies the Square D QO330L200GRB load center worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 200 A, 3-phase outdoor unit.

How to install a Square D QO main lug load center?

Install the Square D QO330L200GRB outdoors on a flat surface, ensuring proper grounding per local codes. Connect incoming feeder conductors to the main lugs; the unit requires a separate main breaker upstream. Use only Square D QO breakers rated for 65kA and 208Y/120/240V AC.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D square d qo - main lug load centers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.