We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

SQUARE D Load Center: 200 A Amps, 208Y/120/240V AC, 18 Spaces, 65kA, 0 Max. No. of Tandem Breakers - Square D QO - Main Lug Load Centers
SQUARE DSquare D QO - Main Lug Load Centers

SQUARE D Load Center: 200 A Amps, 208Y/120/240V AC, 18 Spaces, 65kA, 0 Max. No. of Tandem Breakers

The Square D QO Main Lug Load Center (MPN QO318L200GRB) is a 200 A, 3-phase unit rated for 208Y/120/240V AC with a 65kA short-circuit current rating. It offers 18 spaces, zero tandem breaker capacity, and includes a…

SKU 3G-OTH-609681

Brand
SQUARE D
Item
Load Center: 200 A Amps, 208Y/120/240V AC, 18 Spaces, 65kA, 0 Max. No. of Tandem Breakers
Category
Square D QO - Main Lug Load Centers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SQUARE D
Manufacturer Part Number
QO318L200GRB
Type
65kA, Outdoor
AC
208Y/120/240V
Phase
3
Spaces
18
Voltage
208Y/120/240V AC
Location
Outdoor
Included Enclosure Cover
Surface Cover
Max. No. Of Tandem Breakers
0
Short Circuit Current Rating
65kA
Main Circuit Breaker or Main Lug
Main Lug
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Square D QO Main Lug Load Center (MPN QO318L200GRB) is a 200 A, 3-phase unit rated for 208Y/120/240V AC with a 65kA short-circuit current rating. It offers 18 spaces, zero tandem breaker capacity, and includes a surface cover for outdoor installation.

Frequently Asked Questions

What is the Square D QO318L200GRB load center used for?

The Square D QO318L200GRB is a 200 A, 3-phase main lug load center for outdoor 208Y/120/240V AC applications. It distributes power in commercial or industrial settings where a main breaker is upstream, providing 18 spaces and a 65kA short-circuit current rating.

What are the specifications of the Square D QO318L200GRB?

This Square D QO load center is rated 200 A, 208Y/120/240V AC, 3-phase, with a 65kA short-circuit current rating. It has 18 spaces, zero tandem breaker capacity, and includes a surface cover for outdoor installation. The MPN is QO318L200GRB.

Where to buy the Square D QO318L200GRB load center worldwide?

3G Electric supplies the Square D QO318L200GRB load center worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 200 A, 3-phase outdoor unit.

How to install a Square D main lug load center outdoors?

Mount the Square D QO318L200GRB on a flat vertical surface using the provided enclosure. Connect incoming feeder conductors to the main lugs per local codes. Ensure the enclosure cover is sealed against weather. Always de-energize upstream supply before installation.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D square d qo - main lug load centers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Flush Cover (MPN QO612L100DF). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Flush Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 8 Spaces, 10kA, 8 Max. No. of Tandem Breakers, Surface Cover (MPN QO816L100DS). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 24 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO324L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 125 A Amps, 208Y/120/240V AC, 20 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO320L125G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 225 A Amps, 208Y/120/240V AC, 42 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Outdoor (MPN QO342L225GRB). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 40 A Amps, 120/240V AC, 2 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Surface Cover (MPN QO2L40RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
SQUARE D
Load Center: 100 A Amps, 120/240V AC, 6 Spaces, 10kA, 6 Max. No. of Tandem Breakers, Surface Cover (MPN QO612L100RB). Key specifications — Voltage: 120/240V AC; Short Circuit Current Rating: 10kA; Included Enclosure Cover: Surface Cover; Phase: 1; Main Circuit Breaker or Main Lug: Main Lug; Location: Outdoor.
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.
SQUARE D
Load Center: 200 A Amps, 208Y/120/240V AC, 30 Spaces, 65kA, 0 Max. No. of Tandem Breakers, Indoor (MPN QO330L200G). Key specifications — Voltage: 208Y/120/240V AC; Short Circuit Current Rating: 65kA; Included Enclosure Cover: Order Separately; Phase: 3; Main Circuit Breaker or Main Lug: Main Lug; Location: Indoor.