We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
SiemensSiemens Room Condition Monitors

Siemens Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block

The Siemens Room Pressure Monitor (MPN 547-203A) is a room condition monitor with a measurement range of +/- 0.25" WC (62.5 Pa) and an accuracy of ±0.5% of Full Scale. It features a 2.17-inch display, operates on 18…

SKU 3G-OTH-176171

Also listed as: 547203A · 547 203A

Brand
Siemens
Item
Room Pressure Monitor: +/- 0.25" WC
Category
Siemens Room Condition Monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Siemens
Manufacturer Part Number
547-203A
Type
BACnet, Terminal Block
Accuracy
±0.5% of Full Scale
Display Size
2.17 in
Analog Outputs
SPDT Relay
Measurement Range
+/- 0.25" WC (62.5 Pa)
Operating Voltage
18 to 32V AC
Operating Temperature Range
32°F to 120°F
Operating Humidity - Maximum
95% RH (Non-Condensing)

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Siemens Room Pressure Monitor (MPN 547-203A) is a room condition monitor with a measurement range of +/- 0.25" WC (62.5 Pa) and an accuracy of ±0.5% of Full Scale. It features a 2.17-inch display, operates on 18 to 32V AC, and provides an SPDT relay analog output. The unit is designed for an operating temperature range of 32°F to 120°F and a maximum humidity of 95% RH (non-condensing).

Frequently Asked Questions

What is the Siemens Room Pressure Monitor 547-203A used for?

The Siemens Room Pressure Monitor 547-203A is used to measure and display differential pressure in cleanrooms, labs, and healthcare facilities. It provides a BACnet output for building management systems and an SPDT relay for alarm or control, ensuring critical spaces maintain proper pressurization.

What are the specifications of the Siemens 547-203A room pressure monitor?

The Siemens 547-203A has a measurement range of +/- 0.25" WC (62.5 Pa) with ±0.5% of Full Scale accuracy. It features a 2.17-inch display, operates on 18 to 32V AC, and includes BACnet communication via terminal block. Operating temperature is 32°F to 120°F with 95% RH max humidity.

Where to buy the Siemens 547-203A room pressure monitor worldwide?

3G Electric supplies the Siemens 547-203A room pressure monitor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source genuine Siemens equipment and support your procurement from order to arrival.

How to install the Siemens 547-203A room pressure monitor?

Mount the Siemens 547-203A on a clean, vibration-free surface within the conditioned space. Connect 18 to 32V AC power and terminate BACnet and relay wiring per the terminal block diagram. Ensure pressure ports are correctly oriented and sealed. Follow Siemens installation manual for commissioning and network setup.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens siemens room condition monitors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-103A)
Temperature and Humidity Sensor: Wall Mount, 32°F to 131°F, Polycarbonate, Single Measurement (MPN QFA3212.EWSN)
Siemens
Temperature and Humidity Sensor: Wall Mount, 32°F to 131°F, Polycarbonate, Single Measurement (MPN QFA3212.EWSN)
Temperature and Humidity Sensor: Wall Mount, Digital, 55°F to 95°F, Polycarbonate, Plastic (MPN QFA3230.FWSN)
Siemens
Temperature and Humidity Sensor: Wall Mount, Digital, 55°F to 95°F, Polycarbonate, Plastic (MPN QFA3230.FWSN)
Temperature and Humidity Sensor: Wall Mount, Digital, 32°F to 122°F, Polycarbonate, Plastic (MPN QFA32SS.FWSN)
Siemens
Temperature and Humidity Sensor: Wall Mount, Digital, 32°F to 122°F, Polycarbonate, Plastic (MPN QFA32SS.FWSN)
Siemens
Siemens
Temperature Sensor: Wall Mount, Flush Mount, 32°F to 131°F, Plastic, Single Measurement, Plastic (MPN 536-784B)

More from Siemens

View all Siemens parts
This room condition monitor measures differential pressure with a range of +/- 0.10" WC (25 Pa) and an accuracy of 0.25%. It features a 4.3 in display, analog inputs of 0 to 5 V DC, and operates on 18 to 30V AC. The unit includes a Phoenix Contact MC Plug Kit with (3) Green and (2) Black connectors. Suitable for monitoring room pressure in HVAC applications such as cleanrooms, hospitals, and laboratories
Siemens
This room condition monitor measures differential pressure with a range of +/- 0.10" WC (25 Pa) and an accuracy of 0.25%. It features a 4.3 in display, analog inputs of 0 to 5 V DC, and operates on 18 to 30V AC. The unit includes a Phoenix Contact MC Plug Kit with (3) Green and (2) Black connectors. Suitable for monitoring room pressure in HVAC applications such as cleanrooms, hospitals, and laboratories
Siemens
Siemens
This room condition monitor measures differential pressure with a range of +/- 0.10" WC (25 Pa) and an accuracy of ±0.5% of full scale. It features a 2.17 in display, 0 to 5 V DC analog inputs, and a 4 to 20 mA (2-wire) analog output. Operating on 18 to 30V AC, it is suitable for monitoring pressure in controlled environments such as cleanrooms and laboratories
Siemens
Siemens
This Siemens room condition monitor measures differential pressure with a range of +/- 0.25" WC (62.5 Pa) and accuracy of ±0.25% of full scale. It features a 2.17 in display, SPDT relay output, and operates on 18 to 32V AC. Suitable for monitoring room pressurization in controlled environments such as cleanrooms and laboratories
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.50" WC (125 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-104B)
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-313B)
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block, 2.17 in Display Size (MPN 547-323B)
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block, 2.17 in Display Size (MPN 547-203B)
SIEMENS Room Condition Monitor: +/- 0.25" WC (62.5 Pa), BACnet/P1, Terminal Block, 547-323A
Siemens
SIEMENS Room Condition Monitor: +/- 0.25" WC (62.5 Pa), BACnet/P1, Terminal Block, 547-323A