We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
PIUSI F0020310H DEF Transfer Pump - DEF Transfer Pumps
PIUSIDEF Transfer Pumps

PIUSI F0020310H DEF Transfer Pump

The PIUSI Electric Drum Pump (MPN F0020310H) is a DEF transfer pump designed for 120 V AC operation. It features a 67/100 hp motor, a nylon construction, a maximum flow rate of 9 gpm, and a 1 in BSP connection. This…

SKU 3G-OTH-92058

Brand
PIUSI
Item
F0020310H DEF Transfer Pump
Part Number
F0020310H
Category
DEF Transfer Pumps
Available to Order
Also known as:F0020310HPIUSI
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

PIUSI
Manufacturer Part Number
F0020310H
Type
67/100 hp HP, Nylon, Pump Only
HP
67/100 hp Motor Horsepower Horsepower (HP) is the measurement of a pump motor’s output power. It expresses the rate at which the motor works to operate the pump.
Meter
Not Included
Phase
Single Phase Phase specifies whether single- or three-phase power must be supplied to operate the motor.
UNSPSC
40151532
Features
COMPATIBLE WITH DEF
Runs Dry
No
Frequency
60 Hz
Max. Head
45 ft Maximum Head The maximum vertical distance the pump can push fluid through pipe from the liquid source. To convert to maximum pump pressure (psi), divide maximum feet of head by 2.31.
Standards
ISO 22241
Duty Cycle
20 Minutes On/20 Minutes Off Duty Cycle The interval of time (or how long) a motor runs during the length of operation.
Mount Type
Foot
Cord Length
72 in
Motor Speed
1,400 RPM
Noise Level
75 dB
Nozzle Type
Not Included
Catalog Page
2552
Power Source
Corded Electric
Self-Priming
Yes
Hose Included
Not Included
Pump Kit Type
Pump Only
Rated Voltage
120 V AC Rated Voltage This describes the electrical power that must be supplied to a motor to ensure it operates correctly. The available power supply must match the selected motor exactly.
Seal Material
Nitrile
Discharge Hose
3/4 in
Includes Spout
No
Max. Flow Rate
9 gpm
Overall Length
14 in
Variable Speed
No
Includes Nozzle
No
Nominal Voltage
120V AC
Nozzle Included
Not Included
Pump Connection
1 in BSP
Pump Technology
Diaphragm
Adapter Material
Polypropylene; Stainless Steel
Housing Material
Nylon
Max. Fluid Temp.
104 °F
Min. Fluid Temp.
12 °F
Country of Origin
Italy (subject to change)
Full Load Current
4.7 A
For Container Size
275 gal 330 gal
For Container Type
Tote
Hose/Reel Included
No Hose
Max. Head Pressure
23.2 psi
Pump Connection ID
1 in
Pump Connection OD
1 in
Thermal Protection
Yes
Meter Type Included
No Meter Included
Hose Inside Diameter
3/4 in
Max. Outlet Pressure
22 psi
Includes Bung Adapter
No
Includes Suction Tube
No
Motor Enclosure Design
Totally Enclosed Fan Cooled
Includes Discharge Hose
No
Includes Follower Plate
No Follower Plate Included
Discharge Connection Type
Hose Barb
Container Cover Type Included
No Cover Included

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

PIUSI Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The PIUSI Electric Drum Pump (MPN F0020310H) is a DEF transfer pump designed for 120 V AC operation. It features a 67/100 hp motor, a nylon construction, a maximum flow rate of 9 gpm, and a 1 in BSP connection. This pump-only unit does not include a meter.

Frequently Asked Questions

What is the PIUSI Electric Drum Pump F0020310H used for?

The PIUSI Electric Drum Pump F0020310H is a DEF transfer pump for dispensing diesel exhaust fluid from drums. It is used in fleet maintenance, trucking, and agricultural operations where reliable 120 V AC pumping is required.

What are the specifications of the PIUSI F0020310H drum pump?

The PIUSI F0020310H operates on 120 V AC with a 67/100 hp motor, delivers a maximum flow rate of 9 gpm, and has a 1 in BSP connection. The pump body is nylon, and this pump-only unit does not include a meter.

Where to buy the PIUSI F0020310H drum pump worldwide?

3G Electric supplies the PIUSI F0020310H drum pump worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this DEF transfer pump.

How to install the PIUSI electric drum pump F0020310H?

Install the PIUSI F0020310H by mounting it securely on a standard drum bung, connecting the 1 in BSP discharge line, and wiring to a 120 V AC power source. Always follow PIUSI’s manual for proper grounding and fluid compatibility.

Used in

Common applications for PIUSI
DEF dispensing in fleet maintenance — PIUSI electric drum pump (F00201A8C) for tote-mount transfer
Fuel filtration for diesel generators — PIUSI 300HS filter element (F00611T50) with 10-micron rating
Manual DEF transfer in remote workshops — PIUSI rotary hand pump (F00332B0A) with 10.67 oz per stroke
Rebuilding EX80 fuel pumps — PIUSI shaft seal (R21429000) for leak prevention
Connecting DEF hoses to dispensers — PIUSI polypropylene/stainless steel adapter (F16475000) for Three25 series
Bulk DEF storage management — PIUSI EPDM tote valve (F21863000) with 2.5-inch RPV connection
Not sure this is the right part? Photo-identify it

PIUSI Products

3G Electric supplies PIUSI def transfer pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This tote-mount pump system is designed for dispensing diesel exhaust fluid (DEF) from totes or drums. It features a 2/3 hp motor, 9 gpm max flow rate, and 1 in BSP connection. The kit includes a discharge hose and a nozzle with Nylon/Stainless Steel/Viton construction. Meter not included
PIUSI
This tote-mount pump system is designed for dispensing diesel exhaust fluid (DEF) from totes or drums. It features a 2/3 hp motor, 9 gpm max flow rate, and 1 in BSP connection. The kit includes a discharge hose and a nozzle with Nylon/Stainless Steel/Viton construction. Meter not included
This PIUSI tote-mount DEF dispensing pump system operates on 120 V AC with a 2/3 hp motor, delivering a maximum flow rate of 9 gpm. The kit includes a pump with discharge hose, a digital meter, and a nozzle constructed of nylon, stainless steel, and Viton. It features a 1 in BSP connection and is suited for transferring diesel exhaust fluid in fleet, agricultural, and industrial settings
PIUSI
This PIUSI tote-mount DEF dispensing pump system operates on 120 V AC with a 2/3 hp motor, delivering a maximum flow rate of 9 gpm. The kit includes a pump with discharge hose, a digital meter, and a nozzle constructed of nylon, stainless steel, and Viton. It features a 1 in BSP connection and is suited for transferring diesel exhaust fluid in fleet, agricultural, and industrial settings
PIUSI
PIUSI
This PIUSI drum-mount pump system is designed for dispensing diesel exhaust fluid (DEF) from drums. It operates on 120 V AC and delivers a maximum flow rate of 9 gpm. The kit includes a discharge hose and nozzle; a meter is not included

More from PIUSI

View all PIUSI parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first