MERSEN Surge Protection Device: Three Phase, 347/600V AC Wye, 3 Poles, 4 Wires

The MERSEN STP600Y07M is a three-phase DIN Rail internal-mount surge protective device (SPD) for 347/600V AC Wye systems with 4 wires and 3 poles. It provides L-L mode protection, a voltage protection rating of 1500V…

SKU 3G-OTH-22974

Brand
MERSEN
Item
Surge Protection Device: Three Phase, 347/600V AC Wye, 3 Poles, 4 Wires
Category
DIN Rail Internal-Mount SPDs
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

MERSEN
Manufacturer Part Number
STP600Y07M
Type
L-L/L-N, 200kA
Poles
3
Wires
4
AC Wye
347/600V
Voltage
347/600V AC Wye
Includes
Form C Dry Contact
Filtering
No
Mounting Style
DIN-Rail
Number of Wires
4 Wires
Enclosure Material
Polyethylene Terephthalate
Modes of Protection
L-L
Voltage Protection Rating
1500V (L-N)
Short Circuit Current Rating
200kA
Max. Continuing Operating Voltage
420/840 V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN STP600Y07M is a three-phase DIN Rail internal-mount surge protective device (SPD) for 347/600V AC Wye systems with 4 wires and 3 poles. It provides L-L mode protection, a voltage protection rating of 1500V (L-N), a short circuit current rating of 200kA, and a max. continuing operating voltage of 420/840 V AC. This SPD includes a Form C dry contact and is housed in a polyethylene terephthalate enclosure.

Frequently Asked Questions

What is the MERSEN STP600Y07M surge protection device used for?

The MERSEN STP600Y07M is a three-phase DIN Rail internal-mount SPD designed to protect electrical equipment in 347/600V AC Wye systems from transient overvoltages. It is commonly used in industrial and commercial facilities where reliable surge suppression is critical for sensitive machinery and control systems.

What are the specifications of the MERSEN STP600Y07M?

The MERSEN STP600Y07M operates at 347/600V AC Wye with 4 wires and 3 poles. It provides L-L mode protection, a voltage protection rating of 1500V (L-N), a short circuit current rating of 200kA, and a max. continuing operating voltage of 420/840 V AC. It includes a Form C dry contact and has a polyethylene terephthalate enclosure.

Where to buy the MERSEN STP600Y07M worldwide?

You can source the MERSEN STP600Y07M through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide competitive pricing and reliable sourcing for this MERSEN surge protection device.

How to install the MERSEN STP600Y07M surge protection device?

Install the MERSEN STP600Y07M on a DIN rail inside a suitable electrical panel. Ensure the system is de-energized before mounting. Connect the SPD according to the L-L mode wiring diagram for 347/600V AC Wye systems, using appropriate overcurrent protection. The Form C dry contact can be wired to a monitoring system for remote status indication.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN din rail internal-mount spds. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G, 200kA (MPN STP480YN07M)
MERSEN
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G, 200kA (MPN STP480YN07M)
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 320/640 V AC (MPN STP480Y07M)
MERSEN
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 320/640 V AC (MPN STP480Y07M)
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G, 200kA (MPN STP480YN07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G, 200kA (MPN STP480YN07)
MERSEN Surge Protection Device: Three Phase, 120/208V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 200kA (MPN STP208Y07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 120/208V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 200kA (MPN STP208Y07)
MERSEN Surge Protection Device: Single Phase, 277V AC, 1 Poles, 2 Wires, L-N, 320 V AC, 600V (L-N) (MPN STP277P07M)
MERSEN
MERSEN Surge Protection Device: Single Phase, 277V AC, 1 Poles, 2 Wires, L-N, 320 V AC, 600V (L-N) (MPN STP277P07M)
MERSEN Surge Protection Device: Single Phase, 120/240V AC, 2 Poles, 3 Wires, L-L/L-N, 175/350 V AC (MPN STP240S07M)
MERSEN
MERSEN Surge Protection Device: Single Phase, 120/240V AC, 2 Poles, 3 Wires, L-L/L-N, 175/350 V AC (MPN STP240S07M)

More from MERSEN

View all MERSEN parts
MERSEN Surge Protection Device: Single Phase, 120V AC, 1 Poles, 2 Wires, L-N, 175 V AC, 600V (L-N) (MPN STP120P07M)
MERSEN
MERSEN Surge Protection Device: Single Phase, 120V AC, 1 Poles, 2 Wires, L-N, 175 V AC, 600V (L-N) (MPN STP120P07M)
MERSEN Surge Protection Device: Single Phase, 120/240V AC, 2 Poles, 3 Wires, L-L/L-N, 175/350 V AC (MPN STP240S07)
MERSEN
MERSEN Surge Protection Device: Single Phase, 120/240V AC, 2 Poles, 3 Wires, L-L/L-N, 175/350 V AC (MPN STP240S07)
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 320/640 V AC (MPN STP480Y07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 480V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 320/640 V AC (MPN STP480Y07)
MERSEN Surge Protection Device: Single Phase, 120V AC, 1 Poles, 2 Wires, L-N, 175 V AC, 600V (L-N) (MPN STP120P07)
MERSEN
MERSEN Surge Protection Device: Single Phase, 120V AC, 1 Poles, 2 Wires, L-N, 175 V AC, 600V (L-N) (MPN STP120P07)
MERSEN Surge Protection Device: Single Phase, 230V AC, 1 Poles, 2 Wires, L-N, 275 V AC, 600V (L-N) (MPN STP230P07)
MERSEN
MERSEN Surge Protection Device: Single Phase, 230V AC, 1 Poles, 2 Wires, L-N, 275 V AC, 600V (L-N) (MPN STP230P07)
MERSEN Surge Protection Device: Three Phase, 347/600V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G (MPN STP600YN07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 347/600V AC Wye, 4 Poles, 5 Wires, L-G/L-L/L-N/N-G (MPN STP600YN07)
MERSEN Surge Protection Device: Three Phase, 347/600V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 200kA (MPN STP600Y07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 347/600V AC Wye, 3 Poles, 4 Wires, L-L/L-N, 200kA (MPN STP600Y07)
MERSEN Surge Protection Device: Three Phase, 240V AC Delta, 3 Poles, 4 Wires, L-G/L-L, 275/550 V AC (MPN STP240D07)
MERSEN
MERSEN Surge Protection Device: Three Phase, 240V AC Delta, 3 Poles, 4 Wires, L-G/L-L, 275/550 V AC (MPN STP240D07)