We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
MERSEN GSA1-1/4 Time-Delay Cylindrical Fuse - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN GSA1-1/4 Time-Delay Cylindrical Fuse

The MERSEN GSA Series is a time-delay cylindrical fuse rated at 1.25 A and 250 V AC, with a non-indicating design and dimensions of 1/4 in x 1 1/4 in. It is equivalent to the MDA and GSA fuse series, identified by…

SKU 3G-OTH-26261

Also listed as: GSA114 · GSA1 1 4 · GSA1-1-4

Brand
MERSEN
Item
GSA1-1/4 Time-Delay Cylindrical Fuse
Part Number
GSA1-1/4
Category
Time-Delay Cylindrical Fuses
Available to Order
Also known as:GSA1-1/4MERSEN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

MERSEN
Manufacturer Part Number
GSA1-1/4
Series
GSA
Type
Time-Delay, 1.25 A, Non-Indicating, 1/4 in x 1 1/4 in, MDA & GSA
AC
250 V
Equivalent Fuse Series
MDA & GSA

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN GSA Series is a time-delay cylindrical fuse rated at 1.25 A and 250 V AC, with a non-indicating design and dimensions of 1/4 in x 1 1/4 in. It is equivalent to the MDA and GSA fuse series, identified by manufacturer part number GSA1-1/4.

Frequently Asked Questions

What is the MERSEN GSA Series fuse used for?

The MERSEN GSA Series time-delay fuse is used for overcurrent protection in industrial equipment, motor circuits, and control panels where a temporary inrush current is expected. Its 1.25 A rating and 250 V AC capacity make it suitable for sensitive electronics and machinery requiring reliable, non-indicating protection.

What are the specifications of the MERSEN GSA1-1/4 fuse?

The MERSEN GSA1-1/4 is a time-delay cylindrical fuse rated at 1.25 A and 250 V AC. It has a non-indicating design, dimensions of 1/4 in x 1 1/4 in, and is part of the GSA series, equivalent to the MDA and GSA fuse series. The manufacturer part number is GSA1-1/4.

Where to buy MERSEN GSA1-1/4 fuses worldwide?

You can source MERSEN GSA1-1/4 fuses worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead times on this MERSEN fuse.

How to select the right MERSEN GSA fuse for my application?

To select the correct MERSEN GSA fuse, match the voltage (250 V AC) and current rating (1.25 A) to your circuit requirements. The time-delay feature accommodates motor start-ups or capacitive loads. Verify dimensions (1/4 in x 1 1/4 in) fit your fuse holder. Consult a qualified engineer for specific protection needs.

Used in

Common applications for MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from MERSEN

View all MERSEN parts →
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
MERSEN
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
MERSEN
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
MERSEN
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
MERSEN
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits
MERSEN
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits