We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug - Fuse Blocks for UL Class H & K Fuses
MERSENFuse Blocks for UL Class H & K Fuses

MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug

MERSEN Fuse Blocks for UL Class H & K Fuses.

SKU 3G-OTH-129439

Brand
MERSEN
Item
Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug
Category
Fuse Blocks for UL Class H & K Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

MERSEN
Manufacturer Part Number
61036

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

MERSEN Fuse Blocks for UL Class H & K Fuses.

Frequently Asked Questions

What is a MERSEN fuse block used for?

A MERSEN fuse block securely holds UL Class H and K fuses in industrial circuits, protecting motors, transformers, and control panels from overcurrent. Its open block design simplifies wiring and fuse replacement in electrical distribution systems.

What are the specifications of the MERSEN 61036 fuse block?

The MERSEN 61036 is a 1-pole, 600 V AC open block fuse block with box lug terminals. It is non-indicating and designed for UL Class H and K fuses. This MERSEN part supports reliable overcurrent protection in industrial electrical panels.

Where to buy MERSEN fuse blocks worldwide?

3G Electric supplies MERSEN fuse blocks like the 61036 to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this and other industrial electrical components.

How to install a MERSEN open block fuse block?

Mount the MERSEN fuse block securely on a DIN rail or panel using the provided slots. Connect line and load wires to the box lug terminals, torqueing to manufacturer specifications. Always de-energize circuits before installation and follow NEC guidelines.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN fuse blocks for ul class h & k fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61006)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61006)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60656)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60656)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60606)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60606)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 62001)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 62001)
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60607)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60607)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60608)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60608)

More from MERSEN

View all MERSEN parts
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 62003)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 62003)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60328)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60328)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 21037)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 21037)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20326)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20326)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 24001)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 24001)