We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
LAXCO RHB-10ATC Analog Handheld Refractometer - Analog Handheld Refractometers
LAXCOAnalog Handheld Refractometers

LAXCO RHB-10ATC Analog Handheld Refractometer

The LAXCO RHB-10ATC is an analog handheld refractometer designed for measuring Brix concentration. It offers an accuracy of +/-0.1% and a resolution of 0.1% Brix, with a refractive index range of 0% to 10% Brix. The…

SKU 3G-OTH-377149

Also listed as: RHB10ATC · RHB 10ATC

Brand
LAXCO
Item
RHB-10ATC Analog Handheld Refractometer
Part Number
RHB-10ATC
Category
Analog Handheld Refractometers
Available to Order
Also known as:RHB-10ATCLAXCO
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

LAXCO
Manufacturer Part Number
RHB-10ATC
Type
+/-0.1% Accuracy, Auto, Analog
Accuracy
+/-0.1 %
Overall Dp
7 1/2 in
Overall Wd
1 in
Resolution
0.1% Brix
Test Parameters
Brix
INC Refractometer
Brix
Refractive Index - Max
10 % Brix
Refractive Index - Min
0 % Brix
Automatic Temperature Compensation Included
Automatic

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

LAXCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The LAXCO RHB-10ATC is an analog handheld refractometer designed for measuring Brix concentration. It offers an accuracy of +/-0.1% and a resolution of 0.1% Brix, with a refractive index range of 0% to 10% Brix. The instrument includes automatic temperature compensation for consistent readings.

Frequently Asked Questions

What is the LAXCO RHB-10ATC refractometer used for?

The LAXCO RHB-10ATC is an analog handheld refractometer used to measure Brix concentration, typically in food and beverage quality control, agriculture, and industrial fluid monitoring. It provides accurate readings of sugar or dissolved solids content in liquids.

What are the specifications of the LAXCO RHB-10ATC?

The LAXCO RHB-10ATC has an accuracy of +/-0.1% and a resolution of 0.1% Brix. Its refractive index range is 0% to 10% Brix. It features automatic temperature compensation for consistent readings. The manufacturer part number is RHB-10ATC.

Where to buy the LAXCO RHB-10ATC worldwide?

You can source the LAXCO RHB-10ATC through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to use and maintain the LAXCO RHB-10ATC refractometer?

To use the LAXCO RHB-10ATC, calibrate with distilled water, apply a sample to the prism, and read the Brix scale through the eyepiece. Clean the prism after each use with a soft cloth and avoid harsh chemicals. Store in a dry case to protect the optics.

Not sure this is the right part? Photo-identify it

LAXCO Products

3G Electric supplies LAXCO analog handheld refractometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Related products

More from LAXCO

View all LAXCO parts
Analog handheld refractometer for measuring refractive index, serum protein, and specific gravity (urine). Accuracy ±0.0005, resolution 0.001 SG, with automatic temperature compensation. Used in clinical and veterinary settings for rapid fluid analysis
LAXCO
Analog handheld refractometer for measuring refractive index, serum protein, and specific gravity (urine). Accuracy ±0.0005, resolution 0.001 SG, with automatic temperature compensation. Used in clinical and veterinary settings for rapid fluid analysis
Analog handheld refractometer for measuring ethylene glycol concentration. Provides specific gravity readings with ±0.01 SG accuracy and 0.01 SG resolution. Includes automatic temperature compensation. Suitable for field testing of antifreeze and cooling system fluids
LAXCO
Analog handheld refractometer for measuring ethylene glycol concentration. Provides specific gravity readings with ±0.01 SG accuracy and 0.01 SG resolution. Includes automatic temperature compensation. Suitable for field testing of antifreeze and cooling system fluids
Analog handheld refractometer for measuring Brix concentration in liquids. Covers 0% to 32% Brix with +/-0.1% accuracy and 0.2% resolution. Includes automatic temperature compensation. Dimensions: 9 in depth x 1.5 in width. Suitable for field or lab use in quality control and fluid analysis
LAXCO
Analog handheld refractometer for measuring Brix concentration in liquids. Covers 0% to 32% Brix with +/-0.1% accuracy and 0.2% resolution. Includes automatic temperature compensation. Dimensions: 9 in depth x 1.5 in width. Suitable for field or lab use in quality control and fluid analysis

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first