We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
KDR LINE REACTORS Output Load Reactor - Output Load Reactors
KDR LINE REACTORSOutput Load Reactors

KDR LINE REACTORS Output Load Reactor

The KDR LINE REACTORS Output Load Reactor: Open (SKU KDRULJ2P, MPN KDRULJ2P) is an Ultra Low Z, 365 A Output Current - Max reactor designed for 480V AC input voltage and 300 hp max output power. This open-style…

SKU 3G-OTH-723386

Brand
KDR LINE REACTORS
Item
Output Load Reactor
Part Number
KDRULJ2P
Category
Output Load Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULJ2P
Type
Ultra Low Z, 365 A Output Current - Max
AC
480V
Input Voltage
480V AC
Max Output Power
300 hp

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Output Load Reactor: Open (SKU KDRULJ2P, MPN KDRULJ2P) is an Ultra Low Z, 365 A Output Current - Max reactor designed for 480V AC input voltage and 300 hp max output power. This open-style output load reactor from KDR LINE REACTORS provides impedance for motor drive applications.

Frequently Asked Questions

What is a KDR LINE REACTORS output load reactor used for?

A KDR LINE REACTORS output load reactor, such as the KDRULJ2P, protects motor drives by limiting voltage spikes and reducing harmonic distortion. It is used in industrial applications with 480V AC systems up to 300 hp to improve motor performance and extend equipment life.

What are the specifications of the KDRULJ2P output load reactor?

The KDRULJ2P is an open-style, ultra low impedance output load reactor from KDR LINE REACTORS. It operates at 480V AC input voltage, supports a maximum output current of 365 A, and handles up to 300 hp. It is designed for motor drive applications requiring reliable impedance.

Where to buy KDR LINE REACTORS output load reactors worldwide?

3G Electric supplies KDR LINE REACTORS output load reactors, including the KDRULJ2P, to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 480V AC, 365 A reactor.

How to select the right output load reactor for a motor drive?

Select an output load reactor based on your motor drive's voltage, current, and horsepower. For a 480V AC, 300 hp drive, the KDR LINE REACTORS KDRULJ2P with 365 A capacity and ultra low impedance is suitable. Always match the reactor's ratings to your drive's specifications for optimal protection.

Not sure this is the right part? Photo-identify it→

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS output load reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts →
Open-style output load reactor with ultra low impedance, rated for 480V AC systems. Supports 160 A maximum output current and 125 hp maximum output power. Used to protect variable frequency drives and motors from voltage spikes and harmonics in industrial motor drive applications
KDR LINE REACTORS
Open-style output load reactor with ultra low impedance, rated for 480V AC systems. Supports 160 A maximum output current and 125 hp maximum output power. Used to protect variable frequency drives and motors from voltage spikes and harmonics in industrial motor drive applications
Output load reactor with Ultra Low Z design for use with variable frequency drives and motors. Rated for 480V AC input, 60 hp max output power, and 169 W power loss. Helps reduce voltage spikes, harmonics, and motor heating in industrial motor drive systems
KDR LINE REACTORS
Output load reactor with Ultra Low Z design for use with variable frequency drives and motors. Rated for 480V AC input, 60 hp max output power, and 169 W power loss. Helps reduce voltage spikes, harmonics, and motor heating in industrial motor drive systems

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first