JOHNSON CONTROLS Actuator: Dampers, Floating Point/On/Off/Proportional, Non-Spring Return
The JOHNSON CONTROLS M9335-HGA-2 is a non-fail-safe damper actuator with a 1.3W power rating and 24V AC/DC input voltage. It provides a 0 to 10V DC output signal, supports a 35 to 95° stroke degree, and offers CW/CCW…
SKU 3G-OTH-67672
Also listed as: M9335HGA2 · M9335 HGA 2
Local availability & support
- Delivery
- Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
- Payment
- Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.
Need installation or engineering help?
Ask a question
Product Description
The JOHNSON CONTROLS M9335-HGA-2 is a non-fail-safe damper actuator with a 1.3W power rating and 24V AC/DC input voltage. It provides a 0 to 10V DC output signal, supports a 35 to 95° stroke degree, and offers CW/CCW shaft rotation. This actuator includes an auxiliary switch, is hardwired, and is compatible with building automation systems.
Frequently Asked Questions
What is the JOHNSON CONTROLS M9335-HGA-2 actuator used for?
The JOHNSON CONTROLS M9335-HGA-2 is a non-spring-return damper actuator used in HVAC building automation systems to control air dampers in VAV boxes, mixing plenums, and zone dampers. It modulates damper position via a 0 to 10V DC signal for precise airflow management.
What are the specifications of the JOHNSON CONTROLS M9335-HGA-2?
The M9335-HGA-2 operates on 24V AC/DC with a 1.3W power rating, delivers 310 in-lb torque, and provides a 0 to 10V DC output signal. It supports 35 to 95° stroke with CW/CCW rotation, includes an auxiliary switch, and is hardwired with IP54 protection.
Where to buy the JOHNSON CONTROLS M9335-HGA-2 worldwide?
3G Electric supplies the JOHNSON CONTROLS M9335-HGA-2 worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.
How to install the JOHNSON CONTROLS M9335-HGA-2 actuator?
Mount the actuator directly onto the damper shaft using the supplied bracket, ensuring the shaft aligns with the 35 to 95° stroke range. Wire the 24V AC/DC input and 0 to 10V DC control signal per the wiring diagram. Verify CW/CCW rotation matches damper direction before commissioning.
Used in
Common applications for JOHNSON CONTROLSJOHNSON CONTROLS Products
3G Electric supplies JOHNSON CONTROLS non-fail-safe actuators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.