JOHNSON CONTROLS Actuator: Dampers/Valves, Floating Point, Non-Spring Return, 140 in-lb
The JOHNSON CONTROLS M9116-JGA-2 is a non-fail-safe actuator for dampers and valves, operating on 24V AC/DC with a 0 to 10V DC output signal. It features a 0 to 90° stroke degree, CW/CCW shaft rotation, and screw…
SKU 3G-OTH-67473
Also listed as: M9116JGA2 · M9116 JGA 2
Local availability & support
- Delivery
- Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
- Payment
- Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.
Need installation or engineering help?
Ask a question
Product Description
The JOHNSON CONTROLS M9116-JGA-2 is a non-fail-safe actuator for dampers and valves, operating on 24V AC/DC with a 0 to 10V DC output signal. It features a 0 to 90° stroke degree, CW/CCW shaft rotation, and screw terminals for electrical connection. This actuator is building automation system compatible and is designed for floating point, non-spring return applications with 140 in-lb torque.
Frequently Asked Questions
What is the JOHNSON CONTROLS M9116-JGA-2 actuator used for?
The JOHNSON CONTROLS M9116-JGA-2 is a non-fail-safe actuator used to control dampers and valves in building automation systems. It operates on 24V AC/DC, provides 140 in-lb torque, and features a 0 to 10V DC output signal for precise positioning in HVAC applications.
What are the specifications of the JOHNSON CONTROLS M9116-JGA-2?
The M9116-JGA-2 is a floating point, non-spring return actuator with 140 in-lb torque, 24V AC/DC input, 0 to 10V DC output, 0 to 90° stroke, CW/CCW shaft rotation, and screw terminals. It is building automation system compatible and includes no auxiliary switch.
Where to buy the JOHNSON CONTROLS M9116-JGA-2 worldwide?
3G Electric supplies the JOHNSON CONTROLS M9116-JGA-2 actuator worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.
How to install the JOHNSON CONTROLS M9116-JGA-2 actuator?
Mount the actuator directly onto the damper or valve shaft, ensuring the shaft rotation (CW/CCW) matches the application. Connect 24V AC/DC power and the 0 to 10V DC control signal via the screw terminals. Follow standard HVAC installation practices and verify stroke limits before commissioning.
Used in
Common applications for JOHNSON CONTROLSJOHNSON CONTROLS Products
3G Electric supplies JOHNSON CONTROLS non-fail-safe actuators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.