We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
INDUSTRIAL SCIENTIFIC CL2 Calibration Gas 5 ppm Chlorine in Nitrogen - Calibration Gases for Portable Gas Detectors
INDUSTRIAL SCIENTIFICCalibration Gases for Portable Gas Detectors

INDUSTRIAL SCIENTIFIC CL2 Calibration Gas 5 ppm Chlorine in Nitrogen

The INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen (SKU 18103697, MPN 18103697) is a CL2 calibration gas for portable gas detectors, supplied in a 58 L cylinder with a chlorine mixture of 5 ppm in a nitrogen…

SKU 3G-OTH-549309

Brand
INDUSTRIAL SCIENTIFIC
Item
CL2 Calibration Gas 5 ppm Chlorine in Nitrogen
Part Number
18103697
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

INDUSTRIAL SCIENTIFIC
Manufacturer Part Number
18103697
Type
CL2, Calibration Gas
Gas Mixture
Chlorine 5 ppm
For Use With
Mfr. No. 02509
Background Gas
Nitrogen
Cylinder Capacity
58 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

INDUSTRIAL SCIENTIFIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The INDUSTRIAL SCIENTIFIC Calibration Gas: Nitrogen (SKU 18103697, MPN 18103697) is a CL2 calibration gas for portable gas detectors, supplied in a 58 L cylinder with a chlorine mixture of 5 ppm in a nitrogen background. Designed for use with Mfr. No. 02509, this calibration gas supports accurate sensor verification across 14 industrial departments — and we supply far more than is listed. Our specialist depth in combustion, pumps and controls (as an authorised distributor for brands like FBR, Interpump, Riello, Beckett, Schneider, ABB, Siemens, SKF, Festo, and Fluke) ensures you get the right answer, not just a catalog.

Frequently Asked Questions

What is INDUSTRIAL SCIENTIFIC calibration gas used for?

This calibration gas is used to verify and calibrate portable gas detectors that sense chlorine (CL2). It contains 5 ppm chlorine in a nitrogen background, supplied in a 58 L cylinder, and is designed for use with Mfr. No. 02509.

What are the specifications of INDUSTRIAL SCIENTIFIC calibration gas 18103697?

The INDUSTRIAL SCIENTIFIC calibration gas (MPN 18103697) is a CL2 calibration gas with a gas mixture of chlorine 5 ppm in a nitrogen background. It has a cylinder capacity of 58 L and is intended for use with Mfr. No. 02509.

Where to buy INDUSTRIAL SCIENTIFIC calibration gas in worldwide?

3G Electric supplies and delivers the INDUSTRIAL SCIENTIFIC calibration gas (MPN 18103697) worldwide. We handle full logistics and customs clearance, ensuring you receive the correct gas mixture for your portable gas detectors.

How to use INDUSTRIAL SCIENTIFIC calibration gas for portable gas detectors?

Attach the regulator to the 58 L cylinder, connect to the detector's calibration port, and release the gas at the recommended flow rate. Follow the detector manufacturer's instructions for span calibration. Always use in a well-ventilated area.

Not sure this is the right part? Photo-identify it

INDUSTRIAL SCIENTIFIC Products

3G Electric supplies INDUSTRIAL SCIENTIFIC calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from INDUSTRIAL SCIENTIFIC

View all INDUSTRIAL SCIENTIFIC parts
Calibration gas mixture containing 2 ppm chlorine (CL2) in nitrogen background, supplied in a 58 L cylinder. Used for verifying and adjusting the accuracy of portable gas detectors that sense chlorine
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 2 ppm chlorine (CL2) in nitrogen background, supplied in a 58 L cylinder. Used for verifying and adjusting the accuracy of portable gas detectors that sense chlorine
Calibration gas mixture containing 18% oxygen with nitrogen balance, supplied in a cylinder with CGA 660 connection. Accuracy is +/-5%. Used for verifying and adjusting the response of portable gas detectors that measure oxygen, ensuring proper sensor performance in industrial safety applications
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 18% oxygen with nitrogen balance, supplied in a cylinder with CGA 660 connection. Accuracy is +/-5%. Used for verifying and adjusting the response of portable gas detectors that measure oxygen, ensuring proper sensor performance in industrial safety applications
Calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background, with +/-5% accuracy. Used for routine verification and adjustment of portable gas detectors compatible with Mfr. No. 02509 in industrial safety applications
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background, with +/-5% accuracy. Used for routine verification and adjustment of portable gas detectors compatible with Mfr. No. 02509 in industrial safety applications
Calibration gas mixture containing 100 ppm carbon monoxide balanced with nitrogen, supplied as a 6-pack. Accuracy is +/-10%. Used to verify and adjust the response of portable gas detectors that monitor carbon monoxide in industrial environments
INDUSTRIAL SCIENTIFIC
Calibration gas mixture containing 100 ppm carbon monoxide balanced with nitrogen, supplied as a 6-pack. Accuracy is +/-10%. Used to verify and adjust the response of portable gas detectors that monitor carbon monoxide in industrial environments
Calibration gas cylinder containing 20.9% oxygen balanced with nitrogen, with +/-2% accuracy. Used for verifying and calibrating oxygen sensors in portable gas detectors. Background gas is nitrogen
INDUSTRIAL SCIENTIFIC
Calibration gas cylinder containing 20.9% oxygen balanced with nitrogen, with +/-2% accuracy. Used for verifying and calibrating oxygen sensors in portable gas detectors. Background gas is nitrogen

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first