EXW Singapore — collect or forward from our Singapore office.

3G Electric
HARRIS High-Purity Gas Switchover System - High-Purity Gas Switchover Systems
HARRISHigh-Purity Gas Switchover Systems

HARRIS High-Purity Gas Switchover System

The HARRIS Gas Switchover System (MPN KH2004) is a high-purity gas switchover system featuring a CGA 580 inlet and a 1/4 in NPT female outlet, rated for 125 psig. It is designed with a helium leak integrity rating of…

SKU 3G-OTH-359151

Also listed as: KH 2004 · KH-2004

Brand
HARRIS
Item
High-Purity Gas Switchover System
Part Number
KH2004
Category
High-Purity Gas Switchover Systems
Available to Order
Also known as:KH2004HARRIS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
Warning appliesProp 65 warning
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

HARRIS
Manufacturer Part Number
KH2004
UNSPSC
40142201
CGA Number
CGA 580
Body Finish
Chrome Plated
Catalog Page
2309
For Gas Type
Argon; Helium; Nitrogen
Body Material
Brass
Inlet Connection
CGA 580
Country of Origin
USA (subject to change)
Gas Purity Rating
99.9995 %
Inlet Connection Size
0.965"-14
Inlet Connection Type
NGO
Inlet Thread Direction
Right Hand
Maximum Inlet Pressure
3,000 psig
Outlet Connection Size
1/4 in
Outlet Connection Type
NPT
Maximum Outlet Pressure
125 psig
Outlet Thread Direction
Right Hand
Outlet Connection Gender
Female
Outlet Pressure (Minimum)
0 psig
Helium Leak Integrity Rating
1 x 10-6

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HARRIS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HARRIS Gas Switchover System (MPN KH2004) is a high-purity gas switchover system featuring a CGA 580 inlet and a 1/4 in NPT female outlet, rated for 125 psig. It is designed with a helium leak integrity rating of 1 x 10-6, ensuring reliable performance in demanding industrial applications.

Frequently Asked Questions

What is the HARRIS Gas Switchover System KH2004 used for?

The HARRIS Gas Switchover System KH2004 is used in high-purity gas distribution to automatically switch between two gas cylinders, ensuring uninterrupted supply. It is ideal for industrial applications requiring consistent gas flow, such as laboratories, manufacturing, and welding operations, where purity and reliability are critical.

What are the specifications of the HARRIS KH2004 gas switchover system?

The HARRIS KH2004 features a CGA 580 inlet and a 1/4 in NPT female outlet, rated for 125 psig. It has a helium leak integrity rating of 1 x 10-6, ensuring minimal leakage. The manufacturer part number is KH2004, and it is designed for high-purity gas switchover applications.

Where to buy the HARRIS KH2004 gas switchover system worldwide?

You can source the HARRIS KH2004 gas switchover system worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we provide reliable sourcing for this HARRIS high-purity gas switchover system.

How to install the HARRIS KH2004 gas switchover system?

Install the HARRIS KH2004 by connecting the CGA 580 inlet to your gas cylinder and the 1/4 in NPT female outlet to your downstream piping. Ensure all connections are leak-tested using appropriate methods. Follow standard high-purity gas system best practices, including proper purging and pressure checks, to maintain the 1 x 10-6 helium leak integrity rating.

Used in

Common applications for HARRIS
Industrial fabrication — Harris 43-2 torch handle for oxy-fuel welding, cutting, and brazing
HVAC and refrigeration — Harris Stay-Silv White flux for phos-copper brazing of piping joints
Metal processing — Harris J-63-3 heating nozzle for preheating, bending, or straightening with acetylene
Laboratory and analytical — Harris gas switchover system (KH2004) for uninterrupted high-purity gas supply
Safety systems — Harris 88-5FBHF-RR flashback arrestor for oxygen service in welding and cutting
Facility identification — Harris acid pipe markers for marking piping systems in industrial plants
Not sure this is the right part? Photo-identify it→

HARRIS Products

3G Electric supplies HARRIS high-purity gas switchover systems. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from HARRIS

View all HARRIS parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first