EXW Singapore — collect or forward from our Singapore office.

3G Electric
HARRIS Single Stage Gas Regulator - Air & Inert Gas Regulators
HARRISAir & Inert Gas Regulators

HARRIS Single Stage Gas Regulator

The HARRIS Gas Regulator: Single Stage is an air and inert gas regulator with a CGA 540 inlet and a 9/16"-18 M RH outlet. It features a stainless steel diaphragm and is rated for 125 psig oxygen service, identified…

SKU 3G-OTH-358198

Brand
HARRIS
Item
Single Stage Gas Regulator
Part Number
3002497
Category
Air & Inert Gas Regulators
Available to Order
Also known as:3002497HARRIS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

HARRIS
Manufacturer Part Number
3002497
Type
CGA 540 Inlet, 125 psig, Oxygen
RH Outlet
9/16"-18 M
Inlet Connection
CGA 540
Outlet Connection
9/16"-18 M RH
Diaphragm Material
Stainless Steel

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HARRIS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HARRIS Gas Regulator: Single Stage is an air and inert gas regulator with a CGA 540 inlet and a 9/16"-18 M RH outlet. It features a stainless steel diaphragm and is rated for 125 psig oxygen service, identified by manufacturer part number 3002497.

Frequently Asked Questions

What is the HARRIS 3002497 gas regulator used for?

The HARRIS 3002497 single-stage gas regulator is designed for oxygen service and inert gas applications. It reduces cylinder pressure to a consistent 125 psig outlet, commonly used in welding, cutting, and industrial gas distribution systems where precise flow control is required.

What are the specifications of the HARRIS 3002497 regulator?

The HARRIS 3002497 is a single-stage gas regulator with a CGA 540 inlet and a 9/16"-18 M RH outlet. It features a stainless steel diaphragm and is rated for 125 psig oxygen service. The diaphragm material ensures durability and corrosion resistance in demanding environments.

Where to buy the HARRIS 3002497 regulator worldwide?

3G Electric supplies the HARRIS 3002497 regulator worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we source and deliver this HARRIS part to any country.

How to install the HARRIS single-stage gas regulator?

Ensure the cylinder valve is closed before attaching the regulator. Connect the CGA 540 inlet hand-tight, then open the cylinder valve slowly. Adjust the outlet pressure to 125 psig using the adjusting knob. Always leak-test connections with a soap solution and follow HARRIS guidelines for oxygen service safety.

Used in

Common applications for HARRIS
Industrial fabrication — Harris 43-2 torch handle for oxy-fuel welding, cutting, and brazing
HVAC and refrigeration — Harris Stay-Silv White flux for phos-copper brazing of piping joints
Metal processing — Harris J-63-3 heating nozzle for preheating, bending, or straightening with acetylene
Laboratory and analytical — Harris gas switchover system (KH2004) for uninterrupted high-purity gas supply
Safety systems — Harris 88-5FBHF-RR flashback arrestor for oxygen service in welding and cutting
Facility identification — Harris acid pipe markers for marking piping systems in industrial plants
Not sure this is the right part? Photo-identify it→

HARRIS Products

3G Electric supplies HARRIS air & inert gas regulators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from HARRIS

View all HARRIS parts →
This single-stage regulator is designed for carbon dioxide service, reducing and controlling cylinder pressure. It features a CGA 320 inlet connection and a 9/16"-18 M RH outlet, with a neoprene diaphragm. Suitable for welding, beverage dispensing, and industrial gas applications
HARRIS
This single-stage regulator is designed for carbon dioxide service, reducing and controlling cylinder pressure. It features a CGA 320 inlet connection and a 9/16"-18 M RH outlet, with a neoprene diaphragm. Suitable for welding, beverage dispensing, and industrial gas applications
Single-stage regulator with CGA 346 inlet and 9/16"-18 M RH outlet. Reduces cylinder pressure to a regulated level for breathing air and inert gas applications. Neoprene diaphragm. Maximum inlet pressure 200 psig
HARRIS
Single-stage regulator with CGA 346 inlet and 9/16"-18 M RH outlet. Reduces cylinder pressure to a regulated level for breathing air and inert gas applications. Neoprene diaphragm. Maximum inlet pressure 200 psig
Single-stage gas regulator for reducing and controlling oxygen pressure from cylinders. Features a CGA 024 inlet connection and 9/16"-18 M RH outlet. Neoprene diaphragm. Maximum outlet pressure 125 psig. Suitable for welding, cutting, and medical gas delivery applications
HARRIS
Single-stage gas regulator for reducing and controlling oxygen pressure from cylinders. Features a CGA 024 inlet connection and 9/16"-18 M RH outlet. Neoprene diaphragm. Maximum outlet pressure 125 psig. Suitable for welding, cutting, and medical gas delivery applications
Single-stage regulator for air and inert gases. Features a CGA 346 inlet connection and 1/4" NPT male outlet. Neoprene diaphragm. Maximum outlet pressure 50 psig. Used in industrial gas systems, laboratories, and maintenance applications requiring stable low-pressure gas supply from cylinders with CGA 346 connection
HARRIS
Single-stage regulator for air and inert gases. Features a CGA 346 inlet connection and 1/4" NPT male outlet. Neoprene diaphragm. Maximum outlet pressure 50 psig. Used in industrial gas systems, laboratories, and maintenance applications requiring stable low-pressure gas supply from cylinders with CGA 346 connection
Single-stage gas regulator for oxygen service, with CGA 540 inlet and 9/16"-18 M RH outlet. Reduces cylinder pressure to a controlled 145 psig outlet. Fiber reinforced neoprene diaphragm. Suitable for welding, cutting, and industrial gas distribution systems
HARRIS
Single-stage gas regulator for oxygen service, with CGA 540 inlet and 9/16"-18 M RH outlet. Reduces cylinder pressure to a controlled 145 psig outlet. Fiber reinforced neoprene diaphragm. Suitable for welding, cutting, and industrial gas distribution systems

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first