We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

GASTEC 11L Gas Detection Tube for Nitrogen Oxide (NO), 0.03-14 ppm, 10-Pack - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC 11L Gas Detection Tube for Nitrogen Oxide (NO), 0.03-14 ppm, 10-Pack

The GASTEC Detector Tube: NO (MPN 11L) is a gas detection tube for nitrogen oxide, designed for use with GASTEC GV-100 and GV-110 pumps. Each 10-pack features break-off tips and measures nitrogen oxide from 0.03 to…

SKU 3G-OTH-553183

Brand
GASTEC
Item
11L Gas Detection Tube for Nitrogen Oxide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASTEC
Manufacturer Part Number
11L
Type
Gas Detection Tube, Nitrogen Oxide ( NO ), With Pump, Break-Off Tip, 10 PK
Gas Detected
Nitrogen Oxide
Measurement Range
0.03 to 14 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube: NO (MPN 11L) is a gas detection tube for nitrogen oxide, designed for use with GASTEC GV-100 and GV-110 pumps. Each 10-pack features break-off tips and measures nitrogen oxide from 0.03 to 14 ppm. 3G Electric interprets this demand and supplies the tube as part of our broader industrial offering across 14 departments, with specialist depth in combustion, pumps, and controls.

Frequently Asked Questions

What is the GASTEC Detector Tube 11L used for?

The GASTEC Detector Tube 11L is used to measure nitrogen oxide (NO) concentrations in air, with a range of 0.03 to 14 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps, making it essential for industrial hygiene, combustion monitoring, and environmental safety applications.

What are the specifications of the GASTEC Detector Tube 11L?

The GASTEC Detector Tube 11L detects nitrogen oxide (NO) from 0.03 to 14 ppm. It is a break-off tip tube, supplied in a 10-pack, and requires a GASTEC GV-100 or GV-110 pump for operation. The manufacturer part number is 11L.

Where to buy GASTEC Detector Tubes worldwide?

3G Electric supplies GASTEC Detector Tubes worldwide, handling logistics, customs, and delivery. As a global industrial solutions provider, we source genuine GASTEC 11L tubes for nitrogen oxide detection, ensuring compliance with your application needs across 14 industrial departments.

How to use the GASTEC Detector Tube 11L?

To use the GASTEC Detector Tube 11L, break off both tips, insert the tube into a GASTEC GV-100 or GV-110 pump, and draw the specified sample volume. Read the concentration directly from the tube's colorimetric scale. Always follow the manufacturer's instructions for accurate nitrogen oxide measurement from 0.03 to 14 ppm.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC detector tube 72P for ethyl mercaptan (C2H6S) with a measurement range of 2.5 to 30 ppm. Supplied in packs of 10, designed for use with GASTEC GV-100 and GV-110 pumps. Used for on-site measurement of ethyl mercaptan in industrial environments such as refineries, chemical plants, and odorant injection systems
GASTEC
GASTEC detector tube 72P for ethyl mercaptan (C2H6S) with a measurement range of 2.5 to 30 ppm. Supplied in packs of 10, designed for use with GASTEC GV-100 and GV-110 pumps. Used for on-site measurement of ethyl mercaptan in industrial environments such as refineries, chemical plants, and odorant injection systems
GASTEC detector tube 128 for Stoddard Solvent, with a measurement range of 50 to 8,000 mg/m³. Designed for use with GASTEC GV-100 and GV-110 pumps. Pack of 10 tubes for field detection of solvent concentrations in industrial hygiene and safety monitoring
GASTEC
GASTEC detector tube 128 for Stoddard Solvent, with a measurement range of 50 to 8,000 mg/m³. Designed for use with GASTEC GV-100 and GV-110 pumps. Pack of 10 tubes for field detection of solvent concentrations in industrial hygiene and safety monitoring
GASTEC 3HM gas detection tube for ammonia (NH3) measurement. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.05 to 3.52% vol. Supplied in a 10-pack. Used for industrial safety monitoring in environments where ammonia may be present
GASTEC
GASTEC 3HM gas detection tube for ammonia (NH3) measurement. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.05 to 3.52% vol. Supplied in a 10-pack. Used for industrial safety monitoring in environments where ammonia may be present
GASTEC 122L is a toluene (C7H8) gas detection tube for use with GASTEC GV-100 and GV-110 pumps. It measures toluene concentrations in air from 1 to 100 ppm. Supplied as a 10-pack, it is suitable for industrial hygiene, chemical plant safety, and environmental monitoring
GASTEC
GASTEC 122L is a toluene (C7H8) gas detection tube for use with GASTEC GV-100 and GV-110 pumps. It measures toluene concentrations in air from 1 to 100 ppm. Supplied as a 10-pack, it is suitable for industrial hygiene, chemical plant safety, and environmental monitoring
GASTEC 91L gas detection tube for formaldehyde (CH2O) measurement. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.1 to 40 ppm. Supplied in a 10-pack for spot-check applications in industrial hygiene and indoor air quality monitoring
GASTEC
GASTEC 91L gas detection tube for formaldehyde (CH2O) measurement. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.1 to 40 ppm. Supplied in a 10-pack for spot-check applications in industrial hygiene and indoor air quality monitoring
GASTEC 71H gas detection tube for methyl mercaptan (CH4S) with a measurement range of 20 to 2,700 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in a 10-pack. Suitable for industrial environments where methyl mercaptan may be present
GASTEC
GASTEC 71H gas detection tube for methyl mercaptan (CH4S) with a measurement range of 20 to 2,700 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps. Supplied in a 10-pack. Suitable for industrial environments where methyl mercaptan may be present
GASTEC 111LL is a gas detection tube for measuring methanol (CH3OH) concentrations in air, with a measurement range of 2 to 62 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, each pack contains 10 tubes. Typical applications include industrial hygiene monitoring, leak detection, and process control in environments where methanol may be present
GASTEC
GASTEC 111LL is a gas detection tube for measuring methanol (CH3OH) concentrations in air, with a measurement range of 2 to 62 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, each pack contains 10 tubes. Typical applications include industrial hygiene monitoring, leak detection, and process control in environments where methanol may be present
GASTEC 111L gas detection tube for methanol (CH3OH). Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 20 to 1,000 ppm. Pack of 10 tubes
GASTEC
GASTEC 111L gas detection tube for methanol (CH3OH). Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 20 to 1,000 ppm. Pack of 10 tubes