The GASCO Calibration Gas: Nitrogen (MPN X05NI80CP440004) is a refillable calibration gas for portable gas detectors, featuring a sulfur dioxide mixture of 5 ppm with a background gas of nitrogen and +/-5% accuracy…

SKU 3G-OTH-549004

Brand
GASCO
Item
Refillable Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
X05NI80CP440004
Type
Refillable, +/-5% Accuracy, H2S/N2/O2/SO2, Calibration Gas
Gas Mixture
Sulfur Dioxide 5 ppm
Reusability
Refillable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen (MPN X05NI80CP440004) is a refillable calibration gas for portable gas detectors, featuring a sulfur dioxide mixture of 5 ppm with a background gas of nitrogen and +/-5% accuracy. Designed for use with all OEM gas detectors, this calibration gas supports H2S/N2/O2/SO2 detection applications.

Frequently Asked Questions

What is GASCO calibration gas X05NI80CP440004 used for?

This GASCO refillable calibration gas is used to verify and calibrate portable gas detectors that sense hydrogen sulfide, nitrogen, oxygen, and sulfur dioxide. It contains a 5 ppm sulfur dioxide mixture in nitrogen with +/-5% accuracy, ensuring reliable sensor performance across all OEM gas detectors.

What are the specifications of GASCO calibration gas X05NI80CP440004?

The GASCO X05NI80CP440004 is a refillable calibration gas with a sulfur dioxide mixture of 5 ppm, background gas of nitrogen, and +/-5% accuracy. It is designed for use with all OEM gas detectors and supports H2S/N2/O2/SO2 detection applications.

Where to buy GASCO calibration gas X05NI80CP440004 worldwide?

3G Electric supplies the GASCO X05NI80CP440004 calibration gas worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this refillable calibration gas.

How to use GASCO calibration gas X05NI80CP440004 for gas detector calibration?

Attach the GASCO refillable calibration gas cylinder to your gas detector's calibration adapter. Apply the 5 ppm sulfur dioxide mixture in nitrogen at the recommended flow rate. Allow the sensor to stabilize, then adjust the detector reading to match the gas concentration. Follow the detector manufacturer's instructions for best results.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing Isobutylene 95 ppm in a background of air, with +/-5% accuracy. Equipped with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust detector accuracy in industrial safety applications
GASCO
Disposable calibration gas cylinder containing Isobutylene 95 ppm in a background of air, with +/-5% accuracy. Equipped with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust detector accuracy in industrial safety applications
Calibration gas mixture containing 50 ppm carbon monoxide in a nitrogen background, with +/-5% accuracy. Designed for use with portable gas detectors from all OEMs. Used to verify sensor response and ensure accurate readings in industrial safety applications
GASCO
Calibration gas mixture containing 50 ppm carbon monoxide in a nitrogen background, with +/-5% accuracy. Designed for use with portable gas detectors from all OEMs. Used to verify sensor response and ensure accurate readings in industrial safety applications
Calibration gas mixture containing 20 ppm carbon monoxide in nitrogen, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response in gas detection equipment
GASCO
Calibration gas mixture containing 20 ppm carbon monoxide in nitrogen, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response in gas detection equipment
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
Disposable calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background gas, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for SO2 detection in industrial safety applications
GASCO
Disposable calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background gas, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for SO2 detection in industrial safety applications
Disposable calibration gas cylinder containing 5 ppm oxygen balanced with nitrogen. Designed for verifying and adjusting the accuracy of portable gas detectors used to monitor oxygen levels in confined spaces or low-oxygen environments. Provides +/-5% accuracy and is compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 5 ppm oxygen balanced with nitrogen. Designed for verifying and adjusting the accuracy of portable gas detectors used to monitor oxygen levels in confined spaces or low-oxygen environments. Provides +/-5% accuracy and is compatible with all OEM gas detectors
Calibration gas mixture containing 1,000 ppm carbon dioxide in air, supplied in a 116 L cylinder. Accuracy is +/-5%. Used for verifying and adjusting the response of portable gas detectors to carbon dioxide in industrial safety applications
GASCO
Calibration gas mixture containing 1,000 ppm carbon dioxide in air, supplied in a 116 L cylinder. Accuracy is +/-5%. Used for verifying and adjusting the response of portable gas detectors to carbon dioxide in industrial safety applications
Calibration gas cylinder containing 3000 ppm carbon monoxide in air background gas. Accuracy ±2%. 105 L capacity. For use with all OEM portable gas detectors to verify sensor response before field use
GASCO
Calibration gas cylinder containing 3000 ppm carbon monoxide in air background gas. Accuracy ±2%. 105 L capacity. For use with all OEM portable gas detectors to verify sensor response before field use