We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
GASCO Disposable Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Disposable Calibration Gas

The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring a Hydrogen Chloride mixture at 1,000 ppm with +/-5% accuracy. Designed for use with all OEM gas detectors, it…

SKU 3G-OTH-549655

Brand
GASCO
Item
Disposable Calibration Gas
Part Number
X02NI99CA3400V1
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
X02NI99CA3400V1
Type
Disposable, +/-5% Accuracy, HCL, Calibration Gas, Calibration Gas
Gas Mixture
Hydrogen Chloride 1,000 ppm
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring a Hydrogen Chloride mixture at 1,000 ppm with +/-5% accuracy. Designed for use with all OEM gas detectors, it uses a nitrogen background gas (MPN X02NI99CA3400V1).

Frequently Asked Questions

What is GASCO calibration gas with hydrogen chloride used for?

GASCO calibration gas with hydrogen chloride (HCl) at 1,000 ppm is used to calibrate portable gas detectors that sense HCl. It ensures accurate readings for worker safety in chemical processing, refrigeration, and industrial hygiene applications. The nitrogen background gas provides a stable, inert mixture.

What are the specifications of GASCO calibration gas X02NI99CA3400V1?

The GASCO calibration gas (MPN X02NI99CA3400V1) is a disposable cylinder with a mixture of hydrogen chloride at 1,000 ppm in nitrogen background gas. Accuracy is ±5%. It is designed for use with all OEM gas detectors and is non-refillable.

Where to buy GASCO calibration gas in worldwide?

3G Electric supplies GASCO calibration gas worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order the disposable hydrogen chloride calibration gas (MPN X02NI99CA3400V1) for your gas detectors.

How to use GASCO disposable calibration gas for gas detectors?

Attach the GASCO disposable cylinder to the regulator and flow adapter compatible with your gas detector. Open the valve to release the hydrogen chloride mixture at 1,000 ppm. Follow the detector manufacturer's calibration procedure. Dispose of the cylinder after use; do not refill.

Not sure this is the right part? Photo-identify it

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
GASCO
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
GASCO
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
GASCO
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
GASCO
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
GASCO
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
GASCO
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications
GASCO
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers