We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, H2, Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, H2, Calibration Gas

The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a hydrogen mixture of 1.9% (47.5% LEL) with +/-5% accuracy. It has a 17 L cylinder capacity, uses a CGA 600…

SKU 3G-OTH-549225

Also listed as: 17L8519 · 17L 85 1 9 · 17L-85-1-9

Brand
GASCO
Item
Calibration Gas: Air, Disposable, +/-5% Accuracy, H2, Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
17L-85-1.9
Type
Disposable, +/-5% Accuracy, H2, Calibration Gas
CGA Number
CGA 600
Gas Mixture
Hydrogen (47.5% LEL) 1.9%
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Air
Cylinder Capacity
17 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a hydrogen mixture of 1.9% (47.5% LEL) with +/-5% accuracy. It has a 17 L cylinder capacity, uses a CGA 600 connection, and is compatible with all OEM gas detectors.

Frequently Asked Questions

What is GASCO Calibration Gas: Air used for?

GASCO Calibration Gas: Air is used to calibrate portable gas detectors from all OEMs. It verifies sensor accuracy for hydrogen detection at 1.9% (47.5% LEL) with ±5% accuracy, ensuring reliable readings in industrial safety applications.

What are the specifications of GASCO Calibration Gas: Air?

This disposable calibration gas contains a hydrogen mixture of 1.9% (47.5% LEL) in an air background, with ±5% accuracy. It has a 17 L cylinder capacity, uses a CGA 600 connection, and is compatible with all OEM gas detectors.

Where to buy GASCO Calibration Gas: Air worldwide?

3G Electric supplies GASCO Calibration Gas: Air worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this calibration gas to your facility, regardless of location.

How to use GASCO Calibration Gas: Air for detector calibration?

Connect the GASCO cylinder via its CGA 600 fitting to your gas detector's calibration port. Apply the gas at the recommended flow rate, allow the reading to stabilize, then adjust the detector to match the certified 1.9% hydrogen concentration. Dispose of the cylinder after use.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing butane (C4H10) at 0.414% concentration (22% LEL) in air. Accuracy ±5%. Fitted with CGA 600 connection for use with portable gas detectors from all OEMs. Used to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing butane (C4H10) at 0.414% concentration (22% LEL) in air. Accuracy ±5%. Fitted with CGA 600 connection for use with portable gas detectors from all OEMs. Used to verify and adjust sensor response in industrial safety applications
Calibration gas mixture containing 35 ppm carbon monoxide in an air background, supplied in a 116 L cylinder. Designed for use with all OEM portable gas detectors to verify and adjust sensor accuracy in industrial safety applications
GASCO
Calibration gas mixture containing 35 ppm carbon monoxide in an air background, supplied in a 116 L cylinder. Designed for use with all OEM portable gas detectors to verify and adjust sensor accuracy in industrial safety applications
This calibration gas cylinder contains a mixture of 50 ppm carbon monoxide in nitrogen background gas, with ±5% accuracy. It is used to verify and adjust the response of portable gas detectors in industrial safety applications. The 105 L cylinder is compatible with all OEM gas detectors
GASCO
This calibration gas cylinder contains a mixture of 50 ppm carbon monoxide in nitrogen background gas, with ±5% accuracy. It is used to verify and adjust the response of portable gas detectors in industrial safety applications. The 105 L cylinder is compatible with all OEM gas detectors
Disposable calibration gas cylinder containing 0.5% hydrogen in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response to hydrogen. Commonly used in industrial safety applications such as petrochemical facilities and confined-space entry
GASCO
Disposable calibration gas cylinder containing 0.5% hydrogen in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response to hydrogen. Commonly used in industrial safety applications such as petrochemical facilities and confined-space entry
Disposable calibration gas mixture containing 100 ppm carbon monoxide in nitrogen background, with ±5% accuracy. Compatible with all OEM portable gas detectors. Used for routine calibration of gas detection instruments in industrial environments
GASCO
Disposable calibration gas mixture containing 100 ppm carbon monoxide in nitrogen background, with ±5% accuracy. Compatible with all OEM portable gas detectors. Used for routine calibration of gas detection instruments in industrial environments
Disposable calibration gas cylinder containing 75 ppm sulfur dioxide balanced in nitrogen. Provides +/-5% accuracy for verifying SO2 sensor response in portable gas detectors. Compatible with all OEM gas detectors. Used in industrial safety applications such as chemical processing, pulp and paper, and combustion systems
GASCO
Disposable calibration gas cylinder containing 75 ppm sulfur dioxide balanced in nitrogen. Provides +/-5% accuracy for verifying SO2 sensor response in portable gas detectors. Compatible with all OEM gas detectors. Used in industrial safety applications such as chemical processing, pulp and paper, and combustion systems
Disposable calibration gas mixture containing 11.95% oxygen with nitrogen balance, certified to ±5% accuracy. Used to verify and adjust oxygen sensors in portable gas detectors from all OEMs. Supplied in a single-use cylinder for field calibration of safety instruments monitoring oxygen levels
GASCO
Disposable calibration gas mixture containing 11.95% oxygen with nitrogen balance, certified to ±5% accuracy. Used to verify and adjust oxygen sensors in portable gas detectors from all OEMs. Supplied in a single-use cylinder for field calibration of safety instruments monitoring oxygen levels
This calibration gas cylinder contains a hydrogen mixture (10% LEL, 0.4%) with air as the background gas, offering +/-2% accuracy. With a 105 L capacity, it is used for field or bench calibration of portable gas detectors to verify and adjust their accuracy
GASCO
This calibration gas cylinder contains a hydrogen mixture (10% LEL, 0.4%) with air as the background gas, offering +/-2% accuracy. With a 105 L capacity, it is used for field or bench calibration of portable gas detectors to verify and adjust their accuracy