EXW Singapore — collect or forward from our Singapore office.

3G Electric
GASCO 17L-293A-0.2 Propylene Calibration Gas, 10% LEL, 0.2%, Disposable, CGA 600 - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 17L-293A-0.2 Propylene Calibration Gas, 10% LEL, 0.2%, Disposable, CGA 600

The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a propylene mixture (10% LEL) at 0.2% concentration with +/-5% accuracy. It uses a CGA 600 connection and is…

SKU 3G-OTH-551208

Also listed as: 17L293A02 · 17L 293A 0 2 · 17L-293A-0-2

Brand
GASCO
Item
17L-293A-0.2 Propylene Calibration Gas, 10% LEL, 0.2%, Disposable, CGA 600
Part Number
17L-293A-0.2
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
17L-293A-0.2
Type
Disposable, +/-5% Accuracy, C3H6, Calibration Gas, Calibration Gas
CGA Number
CGA 600
Gas Mixture
Propylene (10% LEL) 0.2%
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Air

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a propylene mixture (10% LEL) at 0.2% concentration with +/-5% accuracy. It uses a CGA 600 connection and is compatible with all OEM gas detectors, with air as the background gas.

Frequently Asked Questions

What is GASCO calibration gas 17L-293A-0.2 used for?

This disposable calibration gas is used to verify and adjust the accuracy of portable gas detectors from all OEMs. The propylene mixture at 10% LEL (0.2% concentration) with +/-5% accuracy ensures reliable sensor response testing in industrial safety applications.

What are the specifications of GASCO calibration gas 17L-293A-0.2?

The GASCO calibration gas (MPN 17L-293A-0.2) is a disposable cylinder with a CGA 600 connection. It contains propylene at 10% LEL (0.2% concentration) in an air background, with +/-5% accuracy. It is compatible with all OEM gas detectors.

Where to buy GASCO calibration gas 17L-293A-0.2 worldwide?

3G Electric supplies the GASCO calibration gas 17L-293A-0.2 to customers worldwide. We handle full logistics, customs clearance, and delivery for this disposable calibration gas, ensuring it reaches your facility ready for use with any OEM gas detector.

How to use GASCO calibration gas 17L-293A-0.2?

Attach the CGA 600 regulator to the disposable cylinder, then connect to your gas detector's inlet. Apply the propylene mixture at the specified flow rate per the detector manual. Allow the reading to stabilise, then adjust the detector calibration as needed. Dispose of the cylinder after use.

Not sure this is the right part? Photo-identify it→

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from GASCO

View all GASCO parts →
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
This calibration gas cylinder contains a mixture of Refrigerant R-12 at 990 ppm in an air background, with +/-2% accuracy. The 105 L cylinder is used to verify and calibrate portable gas detectors in industrial environments, ensuring reliable readings for safety applications
GASCO
This calibration gas cylinder contains a mixture of Refrigerant R-12 at 990 ppm in an air background, with +/-2% accuracy. The 105 L cylinder is used to verify and calibrate portable gas detectors in industrial environments, ensuring reliable readings for safety applications
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
GASCO
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
Disposable calibration gas mixture containing 1.6% oxygen with nitrogen balance, certified to +/-5% accuracy. Used to verify oxygen sensor response in portable gas detectors from all OEM manufacturers. Suitable for routine calibration in industrial safety applications where oxygen deficiency monitoring is required
GASCO
Disposable calibration gas mixture containing 1.6% oxygen with nitrogen balance, certified to +/-5% accuracy. Used to verify oxygen sensor response in portable gas detectors from all OEM manufacturers. Suitable for routine calibration in industrial safety applications where oxygen deficiency monitoring is required
Disposable calibration gas cylinder containing Propane (50% LEL) 1.05% in a background of Air, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
GASCO
Disposable calibration gas cylinder containing Propane (50% LEL) 1.05% in a background of Air, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
Disposable calibration gas mixture containing 2% methane in nitrogen background, with +/-5% accuracy and CGA 590 connection. Used to verify and adjust the accuracy of portable gas detectors that sense methane and oxygen in industrial safety applications
GASCO
Disposable calibration gas mixture containing 2% methane in nitrogen background, with +/-5% accuracy and CGA 590 connection. Used to verify and adjust the accuracy of portable gas detectors that sense methane and oxygen in industrial safety applications
This calibration gas mixture contains 100 ppm carbon monoxide in a nitrogen background, supplied in a 105 L cylinder with +/-5% accuracy. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications such as refineries, chemical plants, and manufacturing facilities
GASCO
This calibration gas mixture contains 100 ppm carbon monoxide in a nitrogen background, supplied in a 105 L cylinder with +/-5% accuracy. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications such as refineries, chemical plants, and manufacturing facilities

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first