We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

GASCO 116ES-452 Calibration Gas: Air, +/-5% Accuracy, C6H14/CO/H2S/N2/O2 - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 116ES-452 Calibration Gas: Air, +/-5% Accuracy, C6H14/CO/H2S/N2/O2

The GASCO Calibration Gas: Air (MPN 116ES-452) is a +/-5% accuracy calibration gas for portable gas detectors, formulated with a mixture of C6H14/CO/H2S/N2/O2 and a background gas of Air. It contains Hydrogen Sulfide…

SKU 3G-OTH-548955

Also listed as: 116ES452 · 116ES 452

Brand
GASCO
Item
116ES-452 Calibration Gas: Air, +/-5% Accuracy, C6H14/CO/H2S/N2/O2
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
116ES-452
Type
+/-5% Accuracy, C6H14/CO/H2S/N2/O2, Calibration Gas, Calibration Gas
Gas Mixture
Hydrogen Sulfide 25 ppm
For Use With
All OEM Gas Detectors
Background Gas
Air

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air (MPN 116ES-452) is a +/-5% accuracy calibration gas for portable gas detectors, formulated with a mixture of C6H14/CO/H2S/N2/O2 and a background gas of Air. It contains Hydrogen Sulfide at 25 ppm and is designed for use with all OEM gas detectors.

Frequently Asked Questions

What is GASCO Calibration Gas 116ES-452 used for?

This GASCO calibration gas is used to verify and adjust the accuracy of portable gas detectors across industrial safety applications. It contains a certified mixture of C6H14, CO, H2S, N2, and O2 with 25 ppm hydrogen sulfide in air, ensuring reliable sensor response for confined-space entry and plant safety programs.

What are the specifications of GASCO 116ES-452 calibration gas?

The GASCO 116ES-452 is a +/-5% accuracy calibration gas with a background gas of air. Its gas mixture includes hydrogen sulfide at 25 ppm, along with C6H14, CO, N2, and O2. It is designed for use with all OEM gas detectors and carries the manufacturer part number 116ES-452.

Where to buy GASCO calibration gas 116ES-452 worldwide?

3G Electric supplies the GASCO 116ES-452 calibration gas to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this calibration gas for portable gas detectors.

How to use GASCO calibration gas 116ES-452 for detector calibration?

Attach the GASCO 116ES-452 cylinder to your gas detector’s calibration adapter using the appropriate regulator. Apply the gas mixture at the flow rate specified by the detector manufacturer. Allow the sensor readings to stabilize, then adjust the detector to match the certified values on the cylinder label.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing 5% propane (C3H8) balanced with nitrogen. Provides +/-5% accuracy for verifying and adjusting the response of portable gas detectors that measure propane. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 5% propane (C3H8) balanced with nitrogen. Provides +/-5% accuracy for verifying and adjusting the response of portable gas detectors that measure propane. Compatible with all OEM gas detectors
Calibration gas mixture of oxygen at 10 ppm in a nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder. Used to verify and adjust the accuracy of portable gas detectors for low oxygen sensing in confined-space safety applications
GASCO
Calibration gas mixture of oxygen at 10 ppm in a nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder. Used to verify and adjust the accuracy of portable gas detectors for low oxygen sensing in confined-space safety applications
Disposable calibration gas mixture containing 9% isobutane in a nitrogen background, with ±5% accuracy and CGA 600 connection. Used to verify and adjust the response of portable gas detectors in industrial safety applications
GASCO
Disposable calibration gas mixture containing 9% isobutane in a nitrogen background, with ±5% accuracy and CGA 600 connection. Used to verify and adjust the response of portable gas detectors in industrial safety applications
Disposable calibration gas cylinder containing 8 ppm hydrogen sulfide in nitrogen background gas. Provides +/-5% accuracy for verifying sensor response of portable gas detectors. Compatible with all OEM gas detectors for routine calibration in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 8 ppm hydrogen sulfide in nitrogen background gas. Provides +/-5% accuracy for verifying sensor response of portable gas detectors. Compatible with all OEM gas detectors for routine calibration in industrial safety applications
Disposable calibration gas mixture containing 2.5% methane in a nitrogen background, with ±5% accuracy. Fitted with a CGA 165 connection for use with portable gas detectors. Used to verify and calibrate combustible gas sensor response in industrial safety applications
GASCO
Disposable calibration gas mixture containing 2.5% methane in a nitrogen background, with ±5% accuracy. Fitted with a CGA 165 connection for use with portable gas detectors. Used to verify and calibrate combustible gas sensor response in industrial safety applications
Disposable calibration gas cylinder with a mixture of 2.5% Oxygen in Nitrogen, offering ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in safety monitoring applications such as confined space entry and industrial area surveillance
GASCO
Disposable calibration gas cylinder with a mixture of 2.5% Oxygen in Nitrogen, offering ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response in safety monitoring applications such as confined space entry and industrial area surveillance
Disposable calibration gas mixture containing 1,000 ppm Refrigerant R-22 (CHClF2) in a background of air. Accuracy is +/-5%. Fitted with a CGA 600 connection for use with portable gas detectors from all OEMs. Used to verify and adjust detector response to refrigerant leaks in HVAC, refrigeration, and process environments
GASCO
Disposable calibration gas mixture containing 1,000 ppm Refrigerant R-22 (CHClF2) in a background of air. Accuracy is +/-5%. Fitted with a CGA 600 connection for use with portable gas detectors from all OEMs. Used to verify and adjust detector response to refrigerant leaks in HVAC, refrigeration, and process environments
Calibration gas mixture containing 250 ppm hexane in air, with ±5% accuracy, supplied in a 105 L cylinder. Used to verify and adjust the response of portable gas detectors in industrial safety applications
GASCO
Calibration gas mixture containing 250 ppm hexane in air, with ±5% accuracy, supplied in a 105 L cylinder. Used to verify and adjust the response of portable gas detectors in industrial safety applications