EXW Singapore — collect or forward from our Singapore office.

3G Electric
GASCO 105ES-80N-150 Calibration Gas, Refrigerant R-123A 150 ppm, 105 L - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 105ES-80N-150 Calibration Gas, Refrigerant R-123A 150 ppm, 105 L

The GASCO Calibration Gas: Nitrogen is a +/-5% accuracy calibration gas for all OEM gas detectors, supplied in a 105 L cylinder. It contains a mixture of Refrigerant R-123A at 150 ppm with a nitrogen background gas…

SKU 3G-OTH-549556

Also listed as: 105ES80N150 · 105ES 80N 150

Brand
GASCO
Item
105ES-80N-150 Calibration Gas, Refrigerant R-123A 150 ppm, 105 L
Part Number
105ES-80N-150
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
105ES-80N-150
Type
+/-5% Accuracy, C4H8, Calibration Gas
Gas Mixture
Refrigerant R-123A 150 ppm
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a +/-5% accuracy calibration gas for all OEM gas detectors, supplied in a 105 L cylinder. It contains a mixture of Refrigerant R-123A at 150 ppm with a nitrogen background gas (MPN 105ES-80N-150).

Frequently Asked Questions

What is GASCO calibration gas with nitrogen used for?

This GASCO calibration gas is used to calibrate all OEM gas detectors, ensuring accurate detection of Refrigerant R-123A. The 105 L cylinder contains a 150 ppm mixture with nitrogen background gas, providing a stable reference for sensor verification in HVAC and industrial safety applications.

What are the specifications of GASCO 105ES-80N-150 calibration gas?

The GASCO 105ES-80N-150 calibration gas has +/-5% accuracy, a 105 L cylinder capacity, and contains Refrigerant R-123A at 150 ppm with nitrogen as the background gas. It is designed for use with all OEM gas detectors and carries the manufacturer part number 105ES-80N-150.

Where to buy GASCO calibration gas in worldwide?

3G Electric supplies GASCO calibration gas worldwide, handling full logistics and customs clearance for international delivery. As a global industrial solutions provider, we source and deliver this 105 L cylinder with Refrigerant R-123A mixture to support your gas detector calibration needs anywhere.

How to use GASCO calibration gas for gas detectors?

To use this GASCO calibration gas, connect the 105 L cylinder to your OEM gas detector via a compatible regulator and flow adapter. Apply the gas at the recommended flow rate, typically 0.5 L/min, and follow the detector's calibration procedure. Always verify the cylinder's expiration date and store upright in a ventilated area.

Not sure this is the right part? Photo-identify it→

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from GASCO

View all GASCO parts →
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder with +/-5% accuracy, containing Pentane (50% LEL) 0.7% in nitrogen background gas. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
This calibration gas cylinder contains a mixture of Refrigerant R-12 at 990 ppm in an air background, with +/-2% accuracy. The 105 L cylinder is used to verify and calibrate portable gas detectors in industrial environments, ensuring reliable readings for safety applications
GASCO
This calibration gas cylinder contains a mixture of Refrigerant R-12 at 990 ppm in an air background, with +/-2% accuracy. The 105 L cylinder is used to verify and calibrate portable gas detectors in industrial environments, ensuring reliable readings for safety applications
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
GASCO
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
Disposable calibration gas mixture containing 1.6% oxygen with nitrogen balance, certified to +/-5% accuracy. Used to verify oxygen sensor response in portable gas detectors from all OEM manufacturers. Suitable for routine calibration in industrial safety applications where oxygen deficiency monitoring is required
GASCO
Disposable calibration gas mixture containing 1.6% oxygen with nitrogen balance, certified to +/-5% accuracy. Used to verify oxygen sensor response in portable gas detectors from all OEM manufacturers. Suitable for routine calibration in industrial safety applications where oxygen deficiency monitoring is required
Disposable calibration gas cylinder containing Propane (50% LEL) 1.05% in a background of Air, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
GASCO
Disposable calibration gas cylinder containing Propane (50% LEL) 1.05% in a background of Air, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
Disposable calibration gas mixture containing 2% methane in nitrogen background, with +/-5% accuracy and CGA 590 connection. Used to verify and adjust the accuracy of portable gas detectors that sense methane and oxygen in industrial safety applications
GASCO
Disposable calibration gas mixture containing 2% methane in nitrogen background, with +/-5% accuracy and CGA 590 connection. Used to verify and adjust the accuracy of portable gas detectors that sense methane and oxygen in industrial safety applications
This calibration gas mixture contains 100 ppm carbon monoxide in a nitrogen background, supplied in a 105 L cylinder with +/-5% accuracy. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications such as refineries, chemical plants, and manufacturing facilities
GASCO
This calibration gas mixture contains 100 ppm carbon monoxide in a nitrogen background, supplied in a 105 L cylinder with +/-5% accuracy. It is used to verify and adjust the accuracy of portable gas detectors in industrial safety applications such as refineries, chemical plants, and manufacturing facilities

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first