We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS XP 60/M is a two-stage gas burner for industrial heating applications, delivering 107–630 kW thermal power with modulating or progressive flame control. Operating at 61–62 dB noise level and IP 40 protection…

SKU 3G-FBR-00534

Also listed as: 00280341 · 002803 41 · 002803-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
13 kg
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
335
fan motor w
75
power kw max
630
power kw min
107
ip protection
IP 40
noisiness dba
61-62
gas consumption
10.7/23.3-63.3
electrical supply
3
power supply info
1N~230V 50Hz
current absorption a
0.6
thermal power mcal h
92/200-542
nominal electric power w
130
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073015_2_B MODULATING GAS฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀OR฀MODULATING GAS฀XP60/MCE-EVO Burners฀for฀gas฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀addition฀ of฀optional฀modulation฀kit฀and฀probe. They฀are฀composed฀by:฀fan฀at฀high฀pressurisation฀with฀reverse฀blades฀and฀combustion฀head฀with฀adjustment฀at฀high฀ efficiency฀and฀high฀flame฀stability. Compact฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀the฀ operations฀of฀setting฀and฀maintenance. Available฀in฀the฀versions฀METHANE฀(natural฀gas)฀or฀L.P.G.฀(to฀specify฀at฀the฀order)฀on฀demand฀specific฀versions฀for฀ town฀gas,฀coal฀gas฀or฀biogas. Gas฀train฀completely฀assembled฀and฀tested;฀complete฀of฀working฀valve฀with฀flow฀adjustment,฀safety฀valve,฀minimum฀ gas฀pressure฀switch฀and฀gas฀filter. Complete฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 GAS฀XP60/MCE-EVO GAS XP60/MCE-EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073015_2_B MODULATING TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60/MCE-EVO MODEL GAS XP60/MCE-EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 92/200-542 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 107/232-630 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 10.7/23.3-63.3 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 4/9-24.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, umidità rel. max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 115.3 / 60 Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 54.5 / 37.4 Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 17.7 / 21.8 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W] 700 Fan motor [W] 550 Nominal motor current absorption [A] 1.4 Nominal auxiliary absorption [A] 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness *** min. - max. [dB(A)] 69-72 Burner weight **** [kg] 34.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Control method Class 3 - The tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]). **** For burner with long head add 1 kg to the weight. [mbar] 11 9 7 5 3 1 GAS XP60/M -1 0 100 200 300 400 500 600 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS XP60/MCE-EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073015_2_B MODULATING DIMENSIONS [MM] A B S A H D R1 G RD TC-TL E M R4 R2 C N R3 Fig. 3 Dimensions GAS XP60/MCE-EVO MODEL A B C D E G H M N S R1 R2 R3 R4 RD GAS฀XP60/MCE-EVO฀-฀D1"-S 200 330 275 150 99 417 100 298 558 20 240 414 472 444 Rp 1 GAS฀XP60/MCE-EVO฀-฀D1"1/4-S 200 330 275 150 99 417 100 298 558 20 240 414 472 444 Rp 1 1/4 GAS฀XP60/MCE-EVO฀-฀D1"1/2-S 200 330 275 150 99 417 100 298 558 20 240 414 480 460 Rp 1 1/2 BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max GAS฀XP60/MCE-EVO mm 160 160 180 M10 205 205 226 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GAS฀XP60/MCE-EVO mm 250 335 ** For different flame lengths, please contact our Technical-Sales Department. GAS XP60/MCE-EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073015_2_B MODULATING BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 Fig. 5 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP60/MCE-EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073015_2_B MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Burner for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe; composed by: • Fan at high pressurisation with reversed blades; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS XP 60/M is a two-stage gas burner for industrial heating applications, delivering 107–630 kW thermal power with modulating or progressive flame control. Operating at 61–62 dB noise level and IP 40 protection, it suits medium to large boiler and furnace installations.

Frequently Asked Questions

Where can I buy the FBR GAS XP 60/M gas burner worldwide?

3G Electric is an authorised distributor of FBR burners, including the GAS XP 60/M. We source and ship to facilities globally, handling all logistics and customs. Lead time on request — contact us for availability and delivery details.

What is the thermal power output of the FBR GAS XP 60/M?

The FBR GAS XP 60/M delivers 107 kW minimum to 630 kW maximum thermal power. It supports two-stage sliding or modulating (PID fully modulating) flame control when equipped with an optional modulation kit and probe.

Is the FBR GAS XP 60/M suitable for large boiler installations?

Yes. The GAS XP 60/M is designed for medium to large boiler and furnace installations. With 630 kW max output, IP 40 protection, 61–62 dB noise level, and a 75 W fan motor, it suits industrial heating applications requiring reliable progressive or modulating control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS XP 60 CE-LX TL EVO Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60 CE-LX TL EVO Cl. | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE-LX TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE-LX TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/M CE-LX TL EVO CL.4 | Variant: metano | Subgroup: Burner
FBR
GAS XP 60/M CE-LX TL EVO CL.4 | Variant: metano | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL