We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS X5/2 CE-LX4 TL is a two-stage gas burner designed for low-emissions heating applications. It delivers 23–400 kW thermal power with a 75 W fan motor and operates on 1/N~230V-50Hz. IP 40 rated, it suits…

SKU 3G-FBR-00381

Also listed as: 00229641 · 002296 41 · 002296-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
11 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
250
fan motor w
75
power kw max
400
power kw min
23
ip protection
IP 40
noisiness dba
61-62
gas consumption
6.8/18.1-40.2
electrical supply
1
power supply info
1/N~230V-50Hz
current absorption a
0.6
thermal power mcal h
58.5/154.8-344
nominal electric power w
130
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES SK071055_B_en GAS BURNERS TWO STAGES GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE Gas burners two stages with: aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X4/2CE GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X1/2CE - GAS X2/2CE MODEL GAS X1/2CE GAS X2/2CE Thermal power min. - max. * [Mcal/h] 15.5/20-50 21/35-80 Thermal power min. - max. * [kW] 18/23.2-58.1 24.4/40.7-93 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.8/2.3-5.8 2.5/4.1-9.4 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.7/0.9-2.3 0.9/1.6-3.6 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - 14/28 Max. pressure at the entry of valves (Pe. max) [mbar] 60 360 Nominal electric power [W] 110 130 Fan motor [W] 75 75 Nominal motor current absorption [A] 0.55 0.55 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 60-61 61-62 Burner weight **** [kg] 11 11.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [mbar] 3 GAS X1/2 GAS X2/2 2 1 0 -1 0 50 100 [kW] 0 50 100 [Mcal/h] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X3/2CE - GAS X4/2CE MODEL GAS X3/2CE GAS X4/2CE Thermal power min. - max. * [Mcal/h] 30/60-150 55/100-200 Thermal power min. - max. * [kW] 34.9/69.8-174 64/116-232 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 3.5/7-17.4 6.4/11.6-23.2 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 1.3/2.7-6.5 2.5/4.5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 14/21 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 11/30 11/19 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 10/28 8/17 Max. pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [W] 200 226 Fan motor [W] 110 200 Nominal motor current absorption [A] 0.77 1.35 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 66-69 66-69 Burner weight **** [kg] 16 19 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [PEDU] 6 5 4 3 2 GAS X3/2 GAS X4/2 1 0 -1 0 50 100 150 200 250 [ kW ] 0 50 100 150 200 [Mcal/h] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X5/2CE MODEL GAS X5/2CE Thermal power min. - max. * [Mcal/h] 70/130-300 Thermal power min. - max. * [kW] 81.4/151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 8.2/15.2-35 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 3.2/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 16/25 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 15/12 Max. pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W]…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS X5/2 CE-LX4 TL is a two-stage gas burner designed for low-emissions heating applications. It delivers 23–400 kW thermal power with a 75 W fan motor and operates on 1/N~230V-50Hz. IP 40 rated, it suits industrial heating systems requiring certified low-NOx combustion performance.

Frequently Asked Questions

Where can I buy the FBR GAS X5/2 CE-LX4 TL gas burner worldwide?

3G Electric is an authorised distributor of FBR gas burners, including the GAS X5/2 CE-LX4 TL model. We handle logistics, customs clearance, and deliver to industrial sites worldwide. Contact us for availability and lead times on this 23–400 kW two-stage unit.

What are the lead time and shipping options?

Lead time on request. 3G Electric arranges worldwide delivery for the FBR GAS X5/2 CE-LX4 TL. Exact timing depends on your location and order quantity. We manage all logistics and documentation to ensure safe arrival of this 11 kg burner.

Is the FBR GAS X5/2 CE-LX4 TL certified for low-emissions use?

Yes. The FBR GAS X5/2 CE-LX4 TL is CE 676 Class 4 certified with NOx emissions ≤60 mg/kWh, meeting EU low-emissions standards. It delivers 23–400 kW thermal power and operates on 1/N~230V-50Hz, making it suitable for compliant industrial heating systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/2 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5/M CE-LX4 TL EL CL.4 | Variant: variant_2 | Subgroup: Burner
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X5 CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
X GAS X5/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X5/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
FBR
GAS X5/2 CE-LX4 TL Cl. | Variant: metano | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL