We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS X2 CE-LX is a single-stage gas burner designed for low-emissions industrial heating applications. It delivers 26–93 kW thermal power with gas consumption of 6.8/18.1–40.2 m³/h, certified for reduced NOx…

SKU 3G-FBR-00435

Also listed as: 00246031 · 002460 31 · 002460-31

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
stage
Single stage
fuel type
Gas low nox
nozzle mm
150
power kw max
93
power kw min
26
power kcal max
542
power kcal min
200
gas consumption
6.8/18.1-40.2
electrical supply
1
thermal power mcal h
58.5/154.8-344

Datasheet Content

GAS BURNERS ONE STAGE SK_071054_E_en GAS X0-X1-X2-X3-X4-X5CE Gas burners one stage with: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or G.P.L. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X0CE Fig. 2 GAS X2CE Fig. 3 GAS X3CE Fig. 4 GAS X4CE Fig. 5 GAS X5CE GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM MODEL GAS X0CE GAS X1CE GAS X2CE GAS X3CE GAS X4CE GAS X5CE Thermal power min. - max. * [Mcal/h] 10-29.5 20-50 35-80 60-150 100-200 130-300 Thermal power min. - max. * [kW] 11.6-34.3 23.2-58.1 40.7-93 69.8-174 116-232 151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.2-3.4 2.3-5.8 4.1-9.4 7-17.5 11.7-23.4 15.2-35.1 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.5-1.3 0.9-2.2 1.6-3.6 2.7-6.8 4.5-9 5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 60 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 7/18 14/31 - - - - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - - 18/24 - - - Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] - - - 14/31 14/21 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. [mbar] - - - - - 16/25 ** Max. pressure at the entry of valves (Pe. max) [mbar] 60 60 360 360 360 360 Nominal electric power [W] 80 110 130 200 226 540 Fan motor [W] 50 75 75 110 200 370 Nominal motor current absorption [A] 0.5 0.6 0.6 0.9 1.1 2.4 Power supply: 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 IP 40 IP 40 IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 52-55 59-60 60-61 64-66 64-66 67-71 Burner weight **** [kg] 8 10 10 13 15 24 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). **** For burners: GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE with cover in steel (F) add 3 kg to the weight. **** For burner GAS X5CE with cover in steel (F) add 5 kg to the weight. [mbar] [kW] [Mcal/h] Fig. 6 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en DIMENSIONS [mm] Fig. 7 Dimensions GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X0CE D1/2"-S 15 140 140 90 43 265 169 72 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X1CE D1/2"-S 15 162 175 90 43 305 210 65 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X2CE D3/4"-S 15 162 175 90 43 305 210 65 150 150 90 150 138 220 262 328 Rp 3/4 3 kg GAS X3CE D1"-S 16 185 195 108 54 340 248 70 200 160 130 250 168 280 337 361 Rp 1 8 kg GAS X4CE D1"-S 20 185 195 125 78 368 248 70 200 200 160 280 173 280 337 385 Rp 1 8 kg Fig. 8 Dimensions GAS X5CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X5CE D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 403 Rp 1 8 kg GAS X5CE CT-D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 403 Rp 1 9 kg GAS X5CE D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 450 Rp 1 1/4 8 kg GAS X5CE CT-D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 450 Rp 1 1/4 9 kg * For different flame lengths, please contact our Technical-Sales Department. BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 9 Boiler plate MODEL L min L** L max M N min N** N max GAS X0CE mm 130 150 170 M8 100 110 130 GAS X1CE mm 130 150 170 M8 100 110 130 GAS X2CE mm 130 150 170 M8 100 110 130 GAS X3CE mm 150 170 170 M8 120 130 140 GAS X4CE mm 170 205 226 M10 130 140 160 GAS X5CE mm 205 226 226 M10 150 150 180 GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners on stage. DETAILED SPECIFICATION Gas burner one stage composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Safety air pressure switch to stop the burner in case of failed or anomalous fan operation; • Gas train with safety valve and adjustment valve; • Ionisation probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS X2 CE-LX is a single-stage gas burner designed for low-emissions industrial heating applications. It delivers 26–93 kW thermal power with gas consumption of 6.8/18.1–40.2 m³/h, certified for reduced NOx emissions and suitable for commercial and industrial combustion systems.

Frequently Asked Questions

Where can I buy the FBR GAS X2 CE-LX gas burner worldwide?

Order the FBR GAS X2 CE-LX directly from 3G Electric, an authorised distributor handling worldwide logistics, customs clearance, and delivery. Lead time on request.

What is the thermal output range of the FBR GAS X2 CE-LX?

The FBR GAS X2 CE-LX delivers 26–93 kW thermal power (200–542 kcal/min). Gas consumption is 6.8/18.1–40.2 m³/h. Single-stage modulation suits commercial and industrial heating systems.

Is the FBR GAS X2 CE-LX compliant with emissions standards?

Yes. The FBR GAS X2 CE-LX is CE 676 class 3 certified with NOx emissions below 80 mg/kWh, meeting low-emissions requirements for industrial combustion applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X2 CE-LX TC Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2 CE-LX TC Cl. | Variant: variant_2 | Subgroup: Burner
GAS X2/M CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/M CE-LX4 TL Cl. | Variant: variant_2 | Subgroup: Burner
GAS X2/2 CE-LX TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/2 CE-LX TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X2/2 CE-LX TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/2 CE-LX TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS X1 CE-LX TL Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X1 CE-LX TL Cl. | Variant: variant_2 | Subgroup: Burner
GAS X1 CE-LX TC Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X1 CE-LX TC Cl. | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL