The FBR GAS P 300/M CE TL MEC is a two-stage gas burner for industrial heating applications, delivering 1000–6500 Mcal/h thermal power with modulating or sliding flame control. Operating at 500 mbar gas pressure with…

SKU 3G-FBR-00577

Also listed as: 0028702 · 002870 2 · 002870-2

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
315 kg
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
495
fan motor w
22
gas pressure
500
power kw max
3488
power kw min
465
ip protection
IP54/IP40
noisiness dba
88-92
gas consumption
117/351-760
electrical supply
3
power supply info
3~400V, 1N~230V - 50Hz
current absorption a
43
thermal power mcal h
1000/3000-6500
nominal electric power w
22.5
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073057_B_en MODULATING GAS BURNERS TWO STAGES PROGRESSIVE OR MODULATING GAS P190/MCE - GAS P250/MCE - GAS P300/MCE Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. Available also special versions with INVERTER and ELECTRONIC BURNER CONTROL. Fig. 1 GAS P250/MCE Fig. 2 GAS P250/MCE GAS P190/MCE - GAS P250/MCE - GAS P300/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073057_B_en MODULATING TECHNICAL DATA GAS P190/MCE - GAS P250/MCE - GAS P300/MCE MODEL GAS P190/MCE GAS P250/MCE GAS P300/MCE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 300/900-1900 330/1000-2500 400/1200-3000 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 349/1046-2209 384/1163-2907 465/1395-3488 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 35/105-222 39/117-292 47/140-351 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14/41-86 15/45-113 18/54-135 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 Minimum pressure gas train D2" - FS50 NATURAL GAS/L.P.G. ** [mbar] 107/43 181/94 268/120 Minimum pressure gas train DN65-FS65 NATURAL GAS/L.P.G. ** [mbar] 46/31 84/54 112/62 Minimum pressure gas train DN80-FS80 NATURAL GAS/L.P.G. ** [mbar] 30/25 56/45 72/48 Minimum pressure gas train DN100-FS100 NATURAL GAS/L.P.G. ** [mbar] 21/22 39/38 52/40 Maximum pressure at the entry of valves (Pe. max) **** [mbar] 360-500 360-500 360-500 Nominal electric power [kW] 5.8 7.8 7.8 Fan motor [kW] 5.5 7.5 7.5 Nominal motor current absorption [A] 12.3 16.3 16.3 Nominal auxiliary absorption [A] 0.6 0.6 0.6 Power supply: 3~400V,1N~230V - 50Hz Electric protection degree: IP40 IP40 IP40 Noisiness *** min. - max. [dB(A)] 79-82 81-85 81-85 Burner weight [kg] 107 108 113 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** 360 mbar for "Honeywell" mod.; 500 mbar for "Dungs" and "Siemens" mod.; 200 mbar for "Krom". OPERATING RANGE DIAGRAM GAS P190/MCE - GAS P250/MCE - GAS P300/MCE [mbar] 16 12 8 4 GAS P190/M GAS P250/M GAS P300/M 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 [kW] 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 [Mcal/h] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS P190/MCE - GAS P250/MCE - GAS P300/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073057_B_en MODULATING DIMENSIONS [MM] Fig. 4 Dimensions GAS P190/MCE - GAS P250/MCE - GAS P300/MCE MODEL A B C D E F G R1 R2 R3 R4 RD Gas train weight GAS P190/MCE - D2" FS50 360 453 974 265 145 422 363 254 509 672 504 Rp 2 21 kg GAS P190/MCE - DN65 FS65 360 453 974 265 145 422 363 254 480 634 688 DN65 40 kg GAS P190/MCE - DN80 FS80 360 453 974 265 145 422 363 254 480 647 708 DN80 46 kg GAS P190/MCE - DN100 FS100 360 453 974 265 145 422 363 254 480 654 748 DN100 52 kg GAS P250/MCE - D2" FS50 360 453 974 270 145 422 363 254 509 672 504 Rp 2 21 kg GAS P250/MCE - DN65 FS65 360 453 974 270 145 422 363 254 480 634 688 DN65 40 kg GAS P250/MCE - DN80 FS80 360 453 974 270 145 422 363 254 480 647 708 DN80 46 kg GAS P250/MCE - DN100 FS100 360 453 974 270 145 422 363 254 480 654 748 DN100 52 kg GAS P300/MCE - D2" FS50 360 453 974 300 145 422 363 254 509 672 504 Rp 2 21 kg GAS P300/MCE - DN65 FS65 360 453 974 300 145 422 363 254 480 634 688 DN65 40 kg GAS P300/MCE - DN80 FS80 360 453 974 300 145 422 363 254 480 647 708 DN80 46 kg GAS P300/MCE - DN100 FS100 360 453 974 300 145 422 363 254 480 654 748 DN100 52 kg GAS P190/MCE - GAS P250/MCE - GAS P300/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073057_B_en MODULATING BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max GAS P190/MCE mm 280 280 320 M14 396 424 438 GAS P250/MCE mm 280 280 320 M14 396 424 438 GAS P300/MCE mm 310 310 320 M14 396 424 438 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TL ** GAS P190/MCE mm 495 GAS P250/MCE mm 495 GAS P300/MCE mm 460 ** For different flame lengths, please contact our Technical-Sales Department. GAS P190/MCE - GAS P250/MCE - GAS P300/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073057_B_en MODULATING BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 3 Fig. 6 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp 3) GAS valve lamp * * In the gas train DN65-FS65, DN80-FS80 and DN100-FS100 there are 2…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR GAS P 300/M CE TL MEC is a two-stage gas burner for industrial heating applications, delivering 1000–6500 Mcal/h thermal power with modulating or sliding flame control. Operating at 500 mbar gas pressure with a 22 W fan motor, it fits medium to large-scale process heating systems requiring flexible load management.

Frequently Asked Questions

Where can I buy the FBR GAS P 300/M CE TL MEC gas burner?

3G Electric is an authorized distributor. We source the FBR GAS P 300/M CE TL MEC worldwide with lead times confirmed on order. We handle all logistics, customs clearance, and delivery to your facility.

What is the lead time and shipping for this gas burner?

Lead time depends on current FBR stock and your location. Contact 3G Electric with your purchase quantity and destination; we arrange all transport and provide an estimated delivery date upon order confirmation.

What thermal power does the FBR GAS P 300/M CE TL MEC deliver?

The burner delivers 465 kW minimum and 3488 kW maximum output in two-stage mode. It operates at 500 mbar gas pressure with a 22 W fan motor and is suitable for medium to large-scale industrial process heating systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 300/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
FBR
GAS P 300/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
GAS P 300/M CE-LX TL MEC Cl. 3. | Variant: variant_2 | Subgroup: Burner with mechanical cam
FBR
GAS P 300/M CE-LX TL MEC Cl. 3. | Variant: variant_2 | Subgroup: Burner with mechanical cam
GAS P 190/M CE TL MEC | Variant: variant_2 | Subgroup: Burner with mechanical cam
FBR
GAS P 190/M CE TL MEC | Variant: variant_2 | Subgroup: Burner with mechanical cam
GAS P 190/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
FBR
GAS P 190/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
GAS P 250/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
FBR
GAS P 250/M CE TL MEC | Variant: variant_1 | Subgroup: Burner with mechanical cam
GAS P 250/M CE TL MEC | Variant: variant_2 | Subgroup: Burner with mechanical cam
FBR
GAS P 250/M CE TL MEC | Variant: variant_2 | Subgroup: Burner with mechanical cam

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL