We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS P 130/2 CE EVO TL is a two-stage gas burner for industrial heating applications, delivering thermal power from 206 to 1324 Mcal/h with a maximum 1540 kW capacity. Operating at IP 40 protection and 82–83 dBA…

SKU 3G-FBR-00410

Also listed as: 00238131 · 002381 31 · 002381-31

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
43 kg
stage
2 stages
fuel type
Gas
nozzle mm
280
fan motor w
2.2
power kw max
1540
power kw min
240
ip protection
IP 40
noisiness dba
82-83
gas consumption
24/71.5-155
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
4.35
thermal power mcal h
206/612-1324
nominal electric power w
2.4
max combustion air temp c
60

Datasheet Content

SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE GAS P130/2CE EVO - GAS P160/2CE Gas burners two stages with: die-cast aluminum body, high pressurisation air blower and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; composed by two stages working valve with flow adjustment, safety valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser. Complete of flange and gasket for installation on generator. SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P130/2CE EVO - GAS P160/2CE MODEL GAS P130/2CE EVO GAS P160/2CE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 206/612-1324 258/765-1647 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 240/712-1540 300/890-1915 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 24/71.5-155 30.2/89.5-192 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 9.3/27.6-59.8 11.6/34.5-74.2 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 52.4/28.2 64.5/40.4 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [kW] 2.4 4.2 Fan motor [kW] 2.2 4 Nominal motor current absorption [A] 4.35 7.45 Nominal auxiliary absorption [A] 0.7 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 Noisiness *** min. - max [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Control method Class 3 - The tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]). GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE 18 GAS P130/2CE EVO 16 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] GAS P130/2CE EVO The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. 16 GAS P160/2CE 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] GAS P160/2CE The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE DIMENSIONS [MM] 320 40 183 211 320 O 209 320 284 20 510 320 TC-TL 148 240 343 545 380 803 - 1388 ** 555 Fig. Dimensions GAS P130/2CE EVO 320 40 183 211 320 O 209 320 284 20 510 320 TC-TL 148 240 402 545 380 803 - 1388 ** 555 Fig. Dimensions GAS P160/2CE ** Overall dimension with the burner out in position of maintenance. TC - TL: See "FLAME TUBE LENGTH" GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE BOILER PLATE The dimensions of the burner fixing flange (holes threaded or studded) must be as per the drawing. *** Recommended hole diameter on the generator. MODEL L min L*** L max M N min N max GAS P130/2CE EVO mm 220 220 250 M14 340 368 GAS P160/2CE mm 220 220 250 M14 340 368 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 280 TL mm 400 **** **** For different flame lengths, please contact our Technical-Sales Department. GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 V V 1 ' Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P 130/2 CE EVO TL is a two-stage gas burner for industrial heating applications, delivering thermal power from 206 to 1324 Mcal/h with a maximum 1540 kW capacity. Operating at IP 40 protection and 82–83 dBA, it runs on 3~400V, 1/N~230V-50Hz electrical supply and suits medium to large-scale combustion systems.

Frequently Asked Questions

Where can I source the FBR GAS P 130/2 CE EVO TL gas burner worldwide?

3G Electric is an authorised distributor of FBR gas burners. We supply the GAS P 130/2 CE EVO TL globally with full logistics and customs handling. Lead time on request via quotation.

What is the thermal power and electrical supply for this burner?

The FBR GAS P 130/2 CE EVO TL delivers 206–1324 Mcal/h thermal power and 240–1540 kW. It operates on 3~400V, 1/N~230V-50Hz at 4.35 A maximum absorption.

Is this burner suitable for medium to large-scale industrial applications?

Yes. The GAS P 130/2 CE EVO TL is a two-stage burner rated IP 40 with 82–83 dBA noise output, designed for medium to large-scale industrial heating requiring modulating thermal control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 130/2 CE EVO TL | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TL | Variant: variant_1 | Subgroup: Burner
GAS P 130/M CE EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TL | Variant: variant_2 | Subgroup: Burner
GAS P 130/M CE EVO TL | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TL | Variant: variant_1 | Subgroup: Burner
GAS P 130/2 CE EVO TC | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TC | Variant: variant_1 | Subgroup: Burner
GAS P 130/2 CE EVO TC | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TC | Variant: variant_2 | Subgroup: Burner
GAS P 130/M CE EVO TC | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TC | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL