We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS P 100/M CE TL EVO is a two-stage gas burner for industrial heating applications, offering modulating or progressive hi-low flame control with thermal output from 172 to 1000 mcal/h. It features IP 40…

SKU 3G-FBR-00447

Also listed as: 00247441 · 002474 41 · 002474-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
52 kg
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
250
fan motor w
1.5
power kw max
1163
power kw min
200
ip protection
IP 40
noisiness dba
81-82
gas consumption
20.1/58.3-116.7
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.6
thermal power mcal h
172/500-1000
nominal electric power w
1.7
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING GAS BURNERS TWO STAGES PROGRESSIVE OR MODULATING GAS P100/MCE EVO Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: die-cast aluminum body, fan at high pressurisation with reverse blades and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. Fig. 1 GAS P100/MCE EVO GAS P100/MCE EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P100/MCE EVO MODEL GAS P100/MCE EVO Thermal power min. 1 st. / min. 2 st. - max. 2 st. * [Mcal/h] 172/500-1000 Thermal power min. 1 st. / min. 2 st. - max. 2 st. * [kW] 200/581-1163 Gas flow G20 (NATURAL GAS) min. 1 st. / min. 2 st. - max. 2 st. * [Nm³/h] 20.1/58.3-116.7 Gas flow G25 (NATURAL GAS) min. 1 st. / min. 2 st. - max. 2 st. * [Nm³/h] 23.8/67.8-135.7 Gas flow G25.3 (NATURAL GAS) min. 1 st. / min. 2 st. - max. 2 st. * [Nm³/h] 22.8/66.3-132.7 Gas flow G31 (L.P.G.) min. 1 st. / min. 2 st. - max. 2 st. * [Nm³/h] 7.8/22.5-45.1 Fuel: NATURAL GAS (second family, G20, G25, G25.3) - L.P.G. (third family, G31) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40 C / -20...+70 C, rel. humidity max. 80% Max. temperature combustion air [ C] 60 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 87/59 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 43/37 Min. pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 33/32 Min. pressure gas train DN65-FS65 NATURAL GAS/L.P.G. ** [mbar] 15/24 Min. pressure gas train DN80-FS80 NATURAL GAS/L.P.G. ** [mbar] 12/23 Maximum pressure at the entry of valves (D 1"1/4 - 1"1/2 - 2") [mbar] 360 Maximum pressure at the entry of valves (DN65 - DN80) [mbar] 500 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.6 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 1 NOx Class, L.P.G. (third family) 2 Noisiness *** min. - max. [dB(A)] 81-82 Burner weight **** [kg] 52 * Reference conditions: Environment temperature 20 C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). **** For burner with long head add 2 kg to the weight. GAS P100/MCE EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING [mbar] 18 F00106 GAS P100/2 CE EVO CAMPO DI LAVORO 1163 7.5 1269 7.8 16988 12.5 1078 13.8 581 14.5 634 16 200 1.5 200 0 1163 7.5 14383 0 383 0.4 581 0 1163 0 988 12.5 1163 7.5 325 1.2 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 �kW� Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS P100/MCE EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING DIMENSIONS [MM] 140 185 268 510 25 TC - TL 181 B 764 290 280 240 294 C A F00124 Fig. 3 Dimensions GAS TRAIN A B C D1"1/4-S 520 347 462 D1"1/2-S 541 361 462 D2"-S 541 361 462 DN65-FS65 663 430 556 DN80-FS80 663 430 556 TC - TL: Please see chapter "Flame tube length" GAS P100/MCE EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. * Suggested dimension of connection between burner and generator. MODEL L min L* L max M N min N max GAS P100/MCE EVO mm 195 195 250 M12 275 325 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 252 TL mm 387 * * For different flame lengths, please contact our Technical-Sales Department. GAS P100/MCE EVO GAS BURNERS TWO STAGES PROGRESSIVE OR SK073067_B_gb MODULATING BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 V V Fig. 4 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P 100/M CE TL EVO is a two-stage gas burner for industrial heating applications, offering modulating or progressive hi-low flame control with thermal output from 172 to 1000 mcal/h. It features IP 40 protection and operates on 3~400V or 1/N~230V-50Hz electrical supply, suitable for commercial and industrial boiler systems.

Frequently Asked Questions

Where can I source the FBR GAS P 100/M CE TL EVO gas burner worldwide?

Order from 3G Electric, an authorized distributor. We handle logistics, customs clearance, and delivery globally. Lead time on request.

What is the thermal output range of the FBR GAS P 100/M CE TL EVO?

The burner delivers 200 kW minimum to 1163 kW maximum output. It supports two-stage hi-low or modulating control via optional modulation kit. Suitable for industrial heating applications.

What are the electrical supply requirements for this FBR gas burner?

The FBR GAS P 100/M CE TL EVO operates on 3~400V or 1/N~230V, 50 Hz. It features IP40 protection and 1.5 kW fan motor, generating 81–82 dB(A) during operation.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 100/M CE TL EVO | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/M CE TL EVO | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE TL EVO | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE TL EVO | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE TL EVO | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 100/2 CE TL EVO | Variant: variant_2 | Subgroup: Burner
GAS P 100/M CE TC EVO | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 100/M CE TC EVO | Variant: variant_2 | Subgroup: Burner
GAS P 100/M CE TC EVO | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/M CE TC EVO | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE TC EVO | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE TC EVO | Variant: variant_1 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL