We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp - Harsh Environment Infrared Thermometers
FLUKEHarsh Environment Infrared Thermometers

FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp

The FLUKE-572-2/CWG is a full-size harsh environment infrared thermometer from FLUKE, featuring a user-selectable multi-language interface and an LCD display. It measures temperatures from -22° to over 1202°F with an…

SKU 3G-OTH-189752

Also listed as: FLUKE5722CWG · FLUKE 572 2 CWG · FLUKE-572-2-CWG

Brand
FLUKE
Item
Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp
Category
Harsh Environment Infrared Thermometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-572-2/CWG
Type
Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE-572-2/CWG is a full-size harsh environment infrared thermometer from FLUKE, featuring a user-selectable multi-language interface and an LCD display. It measures temperatures from -22° to over 1202°F with an accuracy of ±1.0% of reading or ±2.0°F, whichever is greater, and a resolution of 0.1°F. The device includes a work light, tripod mount, USB connectivity, and audible alerts, with a Class 2 laser per IEC 60825-1. It supports Avg/Difference/Max Temp/Min Temp modes with adjustable emissivity from 0.10 to 1.00.

Frequently Asked Questions

What is the FLUKE-572-2/CWG infrared thermometer used for?

The FLUKE-572-2/CWG is a harsh environment infrared thermometer designed for industrial maintenance, electrical troubleshooting, and HVAC applications. It measures surface temperatures from -22°F to over 1202°F with ±1.0% accuracy, making it suitable for monitoring motors, panels, pipes, and furnaces in demanding plant conditions.

What are the specifications of the FLUKE-572-2/CWG?

The FLUKE-572-2/CWG has a temperature range of -22°F to over 1202°F, accuracy of ±1.0% of reading or ±2.0°F, and resolution of 0.1°F. It features adjustable emissivity from 0.10 to 1.00, a Class 2 laser per IEC 60825-1, USB connectivity, tripod mount, work light, and Avg/Difference/Max/Min temperature modes.

Where to buy the FLUKE-572-2/CWG worldwide?

3G Electric supplies the FLUKE-572-2/CWG infrared thermometer worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time—we source and deliver this FLUKE model to any country.

How to select the right emissivity setting on the FLUKE-572-2/CWG?

To select emissivity on the FLUKE-572-2/CWG, adjust the setting from 0.10 to 1.00 based on the target material's surface properties. For shiny metals, use lower values (0.10–0.30); for matte or painted surfaces, use higher values (0.85–0.95). Consult a material emissivity table for accuracy. This FLUKE model allows fine-tuning for reliable readings.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE harsh environment infrared thermometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FLUKE Infrared Thermometer: FLUKE-59 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, Std
FLUKE
FLUKE Infrared Thermometer: FLUKE-59 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, Std
FLIR Infrared Thermometer: TG56-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.01 to 1.00, -22°
FLIR
FLIR Infrared Thermometer: TG56-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.01 to 1.00, -22°
FLUKE Infrared Thermometer: FLUKE-62 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-62 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°
FLUKE
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°
FLUKE
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°

More from FLUKE

View all FLUKE parts
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB
FLUKE
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB
FLUKE Infrared Thermometer: FLUKE-62 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-62 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: Fluke 64 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: Fluke 64 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00