The FLUKE-568 is a full-size infrared thermometer with contact probe capability from FLUKE, featuring a Class II laser and an LCD display. It measures temperatures from -40°F to over 1202°F with an accuracy of ±1.0%…

SKU 3G-OTH-177078

Brand
FLUKE
Item
Infrared Thermometer: FLUKE-568, Min Temp, Adj @ 0.10 to 1.00
Category
Infrared Thermometers with Contact Probes
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-568
Type
Min Temp, Adj @ 0.10 to 1.00, Full Size Thermometer Size
Features
Comes with a Conductive Case to Safely Carry the IR Thermometer Into Hazardous Areas
Standards
Class II Laser
Alert Type
Light
Accuracy °F
±1.0% of Reading or ±2.0° Whichever is Greater
Data Logging
Yes
Resolution °F
0.1°F
Interface - NEW
USB
Max. Emissivity
1.00
Min. Emissivity
0.10
Body Style - NEW
Full Size
Testing Functions
Minimum Temperature
Temperature Alerts
High Temperature
Mounting Style - NEW
Tripod
Intrinsic Safety - NEW
Not Specified Intrinsically Safe
Includes Work Light - NEW
Work Light Included
Max. Temperature Measured
Over 1202° F
Min. Temperature Measured
-40°
Digital Display Screen Type
LCD
Calibration Certificate Type
Not Certified
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE-568 is a full-size infrared thermometer with contact probe capability from FLUKE, featuring a Class II laser and an LCD display. It measures temperatures from -40°F to over 1202°F with an accuracy of ±1.0% of reading or ±2.0°F, whichever is greater, and a resolution of 0.1°F. The unit includes a conductive case for safe use in hazardous areas, a work light, USB interface, data logging, high-temperature alerts, and tripod mounting, with adjustable emissivity from 0.10 to 1.00.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE infrared thermometers with contact probes. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°. Key specifications — Testing Functions: Average; Temperature Alerts: Low Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: FLUKE-566; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°. Key specifications — Testing Functions: Average; Temperature Alerts: Low Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: FLUKE-566; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°. Key specifications — Testing Functions: Maximum Temperature; Temperature Alerts: Low Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-566/NIST; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°. Key specifications — Testing Functions: Maximum Temperature; Temperature Alerts: Low Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-566/NIST; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLIR Infrared Thermometer: TG54-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.01 to 1.00, -22°. Key specifications — Features: Measure Safely; Testing Functions: Maximum Temperature; Temperature Alerts: High Temperature; Standards: RCM; Resolution °F: 0.1°F; Manufacturer Part Number: TG54-2; Mounting Style - NEW: Handheld Only; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLIR
FLIR Infrared Thermometer: TG54-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.01 to 1.00, -22°. Key specifications — Features: Measure Safely; Testing Functions: Maximum Temperature; Temperature Alerts: High Temperature; Standards: RCM; Resolution °F: 0.1°F; Manufacturer Part Number: TG54-2; Mounting Style - NEW: Handheld Only; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00. Key specifications — attr996392: User-Selectable Multi-Language Interface; attr996407: Maximum Temperature; attr996408: Low Temperature; attr996410: IEC 60825-1; attr996414: 0.1°F; attr996767: FLUKE-572-2/CWG; attr1019884: Tripod; attr1019885: Not Specified Intrinsically Safe.
FLUKE
FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00. Key specifications — attr996392: User-Selectable Multi-Language Interface; attr996407: Maximum Temperature; attr996408: Low Temperature; attr996410: IEC 60825-1; attr996414: 0.1°F; attr996767: FLUKE-572-2/CWG; attr1019884: Tripod; attr1019885: Not Specified Intrinsically Safe.
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00. Key specifications — Features: Provides IP40 Rating; Testing Functions: Maximum Temperature; Temperature Alerts: Low Temperature; Standards: 61326-1 EN 61326-2; Resolution °F: 0.2°F; Manufacturer Part Number: FLUKE-59 MAX +; Mounting Style - NEW: Handheld Only; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLUKE
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00. Key specifications — Features: Provides IP40 Rating; Testing Functions: Maximum Temperature; Temperature Alerts: Low Temperature; Standards: 61326-1 EN 61326-2; Resolution °F: 0.2°F; Manufacturer Part Number: FLUKE-59 MAX +; Mounting Style - NEW: Handheld Only; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB. Key specifications — attr996392: User-Selectable Multi-Language Interface; attr996407: Average; attr996408: Low Temperature; attr996410: CMC; attr996414: 0.1°F; attr996767: FLUKE-572-2; attr1019884: Tripod; attr1019885: Not Specified Intrinsically Safe.
FLUKE
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB. Key specifications — attr996392: User-Selectable Multi-Language Interface; attr996407: Average; attr996408: Low Temperature; attr996410: CMC; attr996414: 0.1°F; attr996767: FLUKE-572-2; attr1019884: Tripod; attr1019885: Not Specified Intrinsically Safe.

More from FLUKE

View all FLUKE parts
FLUKE Infrared Thermometer: Fluke-568/NIST, Included, Avg/Difference/Max Temp/Min Temp, USB, -40°. Key specifications — Features: Contact and Non-Contact Thermometer in One; Testing Functions: Difference; Temperature Alerts: High Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-568/NIST; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLUKE
FLUKE Infrared Thermometer: Fluke-568/NIST, Included, Avg/Difference/Max Temp/Min Temp, USB, -40°. Key specifications — Features: Contact and Non-Contact Thermometer in One; Testing Functions: Difference; Temperature Alerts: High Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-568/NIST; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe.
FLUKE Infrared Thermometer: FLUKE-561, Difference/Max Temp/Min Temp, Adj @ 0.30 to 0.95, -40°. Key specifications — Features: Contact and Non-Contact IR Thermometer for Measuring up Close or at a Distance, without a Ladder; Testing Functions: Difference; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: FLUKE-561; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE
FLUKE Infrared Thermometer: FLUKE-561, Difference/Max Temp/Min Temp, Adj @ 0.30 to 0.95, -40°. Key specifications — Features: Contact and Non-Contact IR Thermometer for Measuring up Close or at a Distance, without a Ladder; Testing Functions: Difference; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: FLUKE-561; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE Infrared Thermometer: Fluke-561/CWG, Included, Difference/Max Temp/Min Temp, Full Size Body. Key specifications — Features: Fabric Hook-and-Loop Fastener Pipe Probe for Superheat, Sub-Cooling, and other Contact and Ambient Measurements; Testing Functions: Minimum Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-561/CWG; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.
FLUKE
FLUKE Infrared Thermometer: Fluke-561/CWG, Included, Difference/Max Temp/Min Temp, Full Size Body. Key specifications — Features: Fabric Hook-and-Loop Fastener Pipe Probe for Superheat, Sub-Cooling, and other Contact and Ambient Measurements; Testing Functions: Minimum Temperature; Standards: Class II Laser; Resolution °F: 0.1°F; Manufacturer Part Number: Fluke-561/CWG; Mounting Style - NEW: Tripod; Intrinsic Safety - NEW: Not Specified Intrinsically Safe; Includes Work Light - NEW: Work Light Included.