We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
FBRBurners & Combustion

FBR GAS P 650/M CE TLEL

FBR GAS P 650/M CE TLEL is a two-stage gas burner designed for industrial heating applications, delivering 1000–6500 mcal/h thermal power with modulating or hi-low flame control. The unit features a 22 W fan motor…

SKU 3G-FBR-00775

Also listed as: GASP650MCETLEL · GAS P 650 M CE TLEL · GAS-P-650-M-CE-TLEL

Brand
FBR
Item
GAS P 650/M CE TLEL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
315 kg
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
490
fan motor w
22
power kw max
7558
power kw min
1163
ip protection
IP54/IP40
noisiness dba
88-92
gas consumption
117/351-760
electrical supply
3
power supply info
3~400V, 1N~230V - 50Hz
current absorption a
43
thermal power mcal h
1000/3000-6500
nominal electric power w
22.5
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073027_A_en_gas p650 MODULATING GAS BURNERS TWO STAGES PROGRESSIVE OR MODULATING GAS P650/MCE Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of: working valve class A - safety valve class A - gas valve proving system - minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. Available with mechanical cam or with electronic cam. GAS P650/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073027_A_en_gas p650 MODULATING TECHNICAL DATA GAS P650/MCE MODEL GAS P650/MCE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 1000/3000-6500 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 1163/3488-7558 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 117/351-760 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 45/136-294 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)B/I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train DN65 FS65 NATURAL GAS/L.P.G. ** [mbar] 260/189 Minimum pressure gas train DN80 FS80 NATURAL GAS/L.P.G. ** [mbar] 233/121 Minimum pressure gas train DN100 FS100 NATURAL GAS/L.P.G. ** [mbar] 118/76 Maximum pressure at the entry of valves (Pe. max) [mbar] 500 Nominal electric power [kW] 22.5 Fan motor [kW] 22 Nominal motor current absorption [A] 43 Nominal auxiliary absorption [A] 0.6 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree NATURAL GAS/L.P.G.: IP54/IP40 Noisiness *** min. - max. [dB(A)] 88-92 Burner weight [kg] 315 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM GAS P650/MCE [mbar] 24 20 16 12 GAS P650/M 8 4 0 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 6000 6400 6800 7200 7600 8000 [ kW] 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800 5200 5600 6000 6400 6800 [ Mcal/h] Fig. 1 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS P650/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073027_A_en_gas p650 MODULATING Fig. 2 Dimensions GAS P650/MCE MODEL A B C D E F G R1 R2 R3 R4 RD Gas train weight GAS P650/MCE - DN65 FS65 490 481 1118 420 160 705 440 317 560 714 780 DN65 37 kg GAS P650/MCE - DN80 FS80 490 481 1118 420 160 705 440 317 560 727 800 DN80 47 kg GAS P650/MCE - DN100 FS100 490 481 1118 420 160 705 440 317 590 765 840 DN100 57 kg BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 3 Boiler plate MODEL L min L* L max M N min N* N max GAS P650/MCE mm 430 440 450 M14 552 552 580 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TL ** GAS P650/MCE mm 490 ** For different flame lengths, please contact our Technical-Sales Department. GAS P650/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073027_A_en_gas p650 MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Burner for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe; composed by: • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with steel blast tube and steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment valve class A and valve proving system; • Ionisation probe for flame detection for natural gas versions; • UV probe for flame detection for L.P.G. versions; • IP 54 electric protection level for natural gas versions; • IP 40 electric protection level for L.P.G. versions; • Spherical gas valve servo-controlled; progressive start and free way passage with total opening; • Servomotor for air shutter and for the spherical gas valve; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • Easy extraction of combustion head without get off the burners by bolier; • Maximum gas pressure switch to stop the burner in lock-out in case of the gas pressure is higher then the set point value; • Fan motor start-up with star/delta system; • Set up for the additional specific kit that transforms burner operation as modulating i.e. the modulating kit allows to supply any power between the minimun and the maximum value based on instantaneous loading request. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • 2009/142/CE Directive GAS; • Reference rules: EN676 (gas) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power modulating kits for temperatures; • Power modulating kits for pressures; • Temperature probe 0°C-400°C (PT 100 a 0° C); • Temperature probe 0°C-1200°C (K probe); • Pressure probe 0-3 bar, 0-6 bar. 0-16 bar, 0-20 bar, 0-30 bar; • Noise protection; • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. GAS P650/MCE
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P 650/M CE TLEL is a two-stage gas burner designed for industrial heating applications, delivering 1000–6500 mcal/h thermal power with modulating or hi-low flame control. The unit features a 22 W fan motor, IP54/IP40 protection, and operates on 3~400V, 1N~230V 50Hz power supply. Suitable for commercial and industrial combustion systems requiring flexible capacity management.

Frequently Asked Questions

Where can I buy the FBR GAS P 650/M CE TLEL gas burner in your region?

3G Electric sources the FBR GAS P 650/M CE TLEL for delivery to your location, your location, and across your region. We handle customs documentation, USD invoicing, and all logistics. Contact us for lead time and quotation.

What is the thermal output and control range of this burner?

The FBR GAS P 650/M CE TLEL delivers 1000–6500 mcal/h thermal power. It features two-stage sliding (hi-low flame) or modulating PID control with an optional modulation kit and probe for full modulation capability.

What are the power supply and protection ratings?

The burner operates on 3~400V, 1N~230V 50Hz with a 22 W fan motor. It carries IP54/IP40 protection rating and produces 88–92 dBA noise level, suitable for food processing and industrial heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FBR
FBR
HI-GAS P650/M CE TL
FBR
FBR
GAS P 250/M CE-LX TL EL
FBR
FBR
GAS P 250/M CE-EL TL
FBR
FBR
GAS P 1500/M CE TL EL
FBR
FBR
GAS P 550/M CE-EL TL EVO
FBR
FBR
GAS P 450/M CE-EL TL EVO

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL